Skip to content
ATEX / IECExFDA / USPDNV GLIP65/67NEMA 4X

BURKERT 20016996 Type 2100 Pneumatically Operated 2/2-Way Angle Seat Valve

Burkert Type 2100 pneumatically operated 2/2-way angle seat valve (SKU 20016996) for decentralized automation. Features a stainless steel body, PEEK seal, and high flow rates for steam, gases, and liquids.

BURKERT 20016996 Type 2100 Pneumatically Operated 2/2-Way Angle Seat Valve

Burkert Type 2100 pneumatically operated 2/2-way angle seat valve is specially optimised for decentralized process automation and fulfils tough criteria in process environments. Its unique design allows easy integration of automation units in all expansion stages, from electrical/optical position feedback to pneumatic control and integrated fieldbus interface. Maximum service life and tightness are achieved by the proven self-adjusting V-seal packing gland. The highly integrated system of valve and automation unit is characterised by its compact and smooth design, integrated pilot air ducts, protection classes IP65/67, NEMA Type 4X, and high resistance to chemicals.

BURKERT 20016996 Burkert Type 2100 angle seat valve product overview

Key Features

  • High flow rates
  • Long service life
  • Easy integration of automation units with ELEMENT
  • Flow-optimised stainless steel valve body with sleeve, clamp, or weld connection
  • Suitable for steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, and organic solvents

Product Components

BURKERT 20016996 Burkert Type 2100 2/2-way valve components diagram

1: Transparent cap with position, 2: Actuator cover, 3: Actuator housing, 4: Relief bore, 5: Valve body, 6: Flow direction marking, 7: Port connection, 8: Body connection, 9: Actuator connection, 10: Pilot air port 1, 11: Pilot air port 2

Technical Data

PropertyValue
DesignAngle seat valve
Nominal diameterDN 10...DN 80, NPS 3/8...NPS 3
Operating pressure0...25 bar(g), vacuum variants down to -0.9 bar(g)
Nominal pressurePN 25 (DIN EN 1333), Class 150 (DIN EN 1759)
Pilot pressure2.5...10 bar(g)
Medium temperature-40 °C...+230 °C
Ambient temperature-10 °C...+100 °C
ViscosityMax. 600 mm²/s
Degree of protectionIP65/67

Materials

ElementMaterial
Actuator coverPPS
Actuator casingStainless steel 1.4561 (316Ti)
Packing glandPTFE V-Rings (filled), with spring compensation
Spindle / Swivel plateStainless steel 1.4401 (316)/1.4404 (316L)
Seat sealPTFE, PEEK (Option)
Valve bodyStainless steel CF3M

Control Functions and Flow Direction

Flow Direction Below Seat

Only use flow direction below the seat for liquid media, gases, and vapours. As the medium is present under the swivel plate, the operating pressure contributes to the opening of the valve.

BURKERT 20016996 Burkert Type 2100 flow direction below seat diagram

Flow Direction Above Seat

Only use flow direction above the seat for gases and vapours, and for valves with control function A (closed by spring force in rest position). As the medium is present above the swivel plate, the operating pressure contributes to the closing of the valve.

BURKERT 20016996 Burkert Type 2100 flow direction above seat diagram

WARNING

Risk of damage due to bursting pipes and bursting equipment when the flow is above the seat. In the case of liquid mediums, water hammer can occur causing pipes and the device to burst. Do not use valves with flow above the seat for liquid mediums.

Operating Limits

BURKERT 20016996 Burkert Type 2100 derating curve for ambient and medium temperature

Approvals and Conformities

  • Explosion Protection: ATEX II 2G Ex h IIC T4…T2 Gb / II 2D Ex h IIIC T135 °C…T300 °C Db, IECEx
  • Drinking Water: Suitable for use in drinking water applications (TrinkwasserV)
  • Foods and Beverages/Hygiene: FDA, USP, EC Regulation 1935/2004, China food GB Standards
  • Others: DNV GL classification, Oxygen suitability, Fuel gases (CE), TA Luft

ATEX Safety Instructions

For devices used in potentially explosive atmospheres (Ex area):

  • Ensure that the device or system cannot be switched on unintentionally.
  • The actuator and valve body must be grounded. If a plastic valve body is used, ground the actuator separately.
  • Only use cleaning agents certified for explosive environments.
  • Take appropriate measures to ensure that static electricity cannot build up in the potentially explosive area.