Skip to content
DN 50PN 25 / Class 150Stainless Steel 316LPTFE / PEEK SealATEX / IECEx Optional

BURKERT 20117041 Type 2921 Manual 2/2-Way Globe Valve

BURKERT 20117041 Type 2921 manually operated 2/2-way globe valve. Features DN 50 flange connection, stainless steel body, PTFE/PEEK seal, and handles 0-20 bar.

BURKERT 20117041 Type 2921 Manual 2/2-Way Globe Valve

BURKERT 20117041 Type 2921 is a manually operated 2/2-way globe valve consisting of a manual actuator and a 2-way body made of stainless steel. With a high-quality valve body, the manually operated valve offers diverse usage options to shut off both neutral and aggressive gaseous and liquid media. The tried-and-tested self-adjusting packing gland guarantees optimal tightness and enables low-maintenance operation, even at high switching cycles. Depending on the application, the soft PTFE or PEEK seal ensures a reliable valve seat seal under challenging operating conditions. The actuator is made of high-quality plastic (PPS) suitable for demanding environments, possesses a visual position indicator, and can be optionally equipped with stroke limitation and locking.

BURKERT 20117041 Type 2921 manually operated 2/2-way globe valve

Approvals and Conformities

In accordance with the Declaration of Conformity, the product is compliant with the EU Directives, including the Pressure Equipment Directive 2014/68/EU.

Explosion Protection (Optional) As a category 2 device suitable for zone 1/21 and zone 2/22 (valid for the variable code PX51).

  • ATEX: EPS 18 ATEX 2 008 XII 2G Ex h IIC T4...T2 Gb / II 2D Ex h IIIC T135 °C...T300 °C Db
  • IECEx: IECEx EPS 18.0007X Ex h IIC T4...T2 Gb / Ex h IIIC T135 °C...T300 °C Db

Drinking Water Suitable for use in drinking water applications. The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV). Stainless steel body PF39 is suitable for products with medium temperature up to 85 °C (hot water).

Foods and Beverages / Hygiene

  • FDA: All wetted materials are compliant with the Code of Federal Regulations published by the FDA (valid for variable code PL02, PL03).
  • USP: All wetted materials are biocompatible according to the United States Pharmacopeial Convention (valid for variable code PL04).
  • EC Regulation 1935/2004: All wetted materials are compliant with EC Regulation 1935/2004/EC (valid for variable code PL01, PL02).
  • China GB Standards: All wetted materials are compliant with the requirement of China food GB Standards (valid for variable code PL10).

Materials

BURKERT 20117041 Type 2921 material specifications and components

No.ElementMaterial
1CoverPolyamide (PA)
2ScrewStainless steel 1.4301
3Locking deviceStainless steel 1.4305
4HandwheelPolyphenylene sulphide (PPS)
5Visual position indicator with scalePolyamide (PA)
6Packing glandPTFE V-rings (filled), with spring compensation
7SpindleStainless steel 1.4401 (316)/1.4404 (316L)
8Spindle guideDN 15...DN 50: PEEK
DN 65...DN 100: Stainless steel 1.4401 (316)/1.4404 (316L)
9Housing sealGraphite
10Swivel plateStainless steel 1.4401 (316)/1.4404 (316L)
11Seat sealPTFE or PEEK
12Valve seat with O-ringStainless steel 1.4571, EPDM
13Valve bodyStainless steel 316L/CF3M

Dimensions

Actuator

BURKERT 20117041 Type 2921 actuator dimensions

Nominal connection size (pipe) [DN][NPS]Handwheel diameter ∅ [mm]H1H2 (locking)
151/245 (S)217224
203/445 (S)224230
25145 (S)228234
321 1/445 (S)296303
401 1/245 (S) (at <16 bar), 110 (M)301307
502110 (M)307313
652 1/2160 (L)361368
803160 (L)369375
1004160 (L)379385

Body with Flange Connection

BURKERT 20117041 Type 2921 body with flange connection dimensions

DN∅ DFLF∅ BFAF∅ DA x α∅ MF
15951306516144 x 90°18.1
201051507518144 x 90°23.7
251151608518144 x 90°29.7
3214018010018184 x 90°38.4
4015020011018184 x 90°44.3
5016523012520184 x 90°56.3
6518529014522188 x 45°66.0
8020031016024188 x 45°81.0
10023535019024228 x 45°100.0

(Table shows DIN EN 1092 PN 25 FTF 1 according to DIN EN 558-1)

Body with Threaded Connection

BURKERT 20117041 Type 2921 body with threaded connection dimensions

Body with Welded Connection

BURKERT 20117041 Type 2921 body with welded connection dimensions

Body with Clamp Connection

BURKERT 20117041 Type 2921 body with clamp connection dimensions

Installation and Operation

Flow Direction

The valve seat is always closed against the medium flow. The flow direction should therefore be set such that the valve reaches the flow beneath the valve seat.

BURKERT 20117041 Type 2921 flow direction below seat

Position Indicator

When turning the handwheel anticlockwise, the reproducible stroke scale becomes visible between the position indicator and the handwheel.

BURKERT 20117041 Type 2921 visual position indicator

INFO

The visibility of the stroke scale is not directly correlated with the closed position of the valve. Depending on the valve design, the repeatable stroke scale may not be visible when the valve is open, or be visible when the valve is closed.

Set Stroke Limit (Optional)

Setting the minimum and maximum stroke limit is possible as an option. An adjusting sleeve is used for this purpose.

BURKERT 20117041 Type 2921 stroke limit adjustment

Lock Handwheel (Optional)

It is also an option to lock the handwheel to prevent unintentional or unauthorised operation of the valve. The locking pin has a bore (Ø 3.8) and can be secured against unauthorised use with a padlock.

BURKERT 20117041 Type 2921 handwheel locking mechanism

Safety Instructions

DANGER

Risk of injury due to high pressure and escaping medium Switch off the pressure before working on the device or system. Vent or drain the lines.

WARNING

Risk of crushing by mechanically powered parts The upwards and downwards movement of the device means there is a risk of crushing. Do not reach into the openings of the valve body.

DANGER

Explosion hazard due to electrostatic charge! (For ATEX/IECEx versions) If there is a sudden discharge from electrostatically charged devices or individuals, there is a risk of explosion in the potentially explosive area.

  • Take appropriate measures to ensure that no electrostatic charges can build up in the potentially explosive area.
  • Only clean the device surface by wiping it gently with a damp or antistatic cloth.
  • Earth the actuator and the valve body.
  • If a plastic body is used, earth the actuator separately.