BURKERT 309490 (Type 2060) pneumatically operated 2/2-way angle seat valve. Features a stainless steel actuator, PTFE seat seal, up to 16 bar operating pressure, and -10 to 185 °C medium temperature.

BURKERT 309490 (Type 2060) pneumatically operated 2/2-way angle seat valve with a stainless steel actuator fulfills the demands of tough process environments. Unrivalled life time and sealing integrity is guaranteed by the trusted self-adjusting packing gland. The stainless steel actuator has been designed for tough applications, and laser welding ensures it is both cleanable and robust. With a ducted exhaust air port, the actuator can be operated isolated from the environment to guarantee an optimum life time and hygiene. High flow rates are attained with the optimised stainless steel angle seat body.
This specific 309490 model features Control Function B (normally open), a PTFE seat seal, a nominal seat diameter of 25 mm, and is rated for operating pressures up to 16 bar and medium temperatures from -10 °C to 185 °C. All wetted parts comply with the EC Directive 1935/2004.
| Product properties | |
|---|---|
| Design | Angle seat valve |
| Nominal diameter | DN 10...DN 80, NPS 3/8...NPS 3 |
| Safety setting | Normally closed (control function A), normally open (control function B) |
| Flow direction | Flow to open (below seat), flow to close (above seat) |
| Operating pressure | 0 bar(g)...25 bar(g) (Model 309490: 0-16 bar) |
| Pilot pressure | 2...10.5 bar(g) |
| Seat leakage | Leakage rate A (DIN EN 12266-1), seat seal PTFE and PEEK, test medium air |
| Medium | Steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, organic solvents |
| Medium temperature | -40...+230 °C (Model 309490: -10...+185 °C) |
| Viscosity | Max. 600 mm²/s |
| Control medium | Air, neutral gases |
| Ambient temperature | -10...+130 °C |
| Degree of protection | IP65/67 |
| Installation position | As required, preferably with actuator upright |
Depending on the variant, the valve seat is closed with or against the medium flow. Spring action (CF A) or pneumatic pilot pressure (CF B and CF I) generate the closing force on the swivel plate. Force is transmitted through a spindle connected to the piston actuator.
WARNING
Risk of damage due to bursting pipes and bursting equipment when the flow is above the seat. In the case of liquid mediums, water hammer can occur causing pipes and the device to burst. Do not use valves with flow above the seat for liquid mediums.
Actuator size 50 (D), 70 (M), 90 (N), 130 (P)

| No. | Element | Material |
|---|---|---|
| 1 | Transparent cover | Optical position indicator Polysulfone PSU |
| 2 | Pilot air ports | Threaded bushing G 1/8" Stainless steel 1.4404 (316L) |
| 3 | Spring support | Stainless steel 1.4308 |
| 4 | Spindle extension | Stainless steel 1.4104 |
| 5 | Actuator casing | Stainless steel 1.4404 (316L) |
| 6 | Piston seal | FKM |
| 7 | Actuator base (interface) | Stainless steel 1.4308 |
| 8 | Spring | Stainless steel 1.4310 |
| 9 | Pipe | Stainless steel 1.4401 (316)/1.4404 (316L) |
| 10 | Packing gland | PTFE V-Rings (filled), with spring compensation |
| 11 | Spindle | Stainless steel 1.4401 (316)/1.4404 (316L) |
| 12 | Spindle guide | PTFE (filled) for actuator size 50(D) / PEEK for actuator size 70(M), 90(N), 130(P) |
| 13 | Swivel plate | Stainless steel 1.4401 (316)/1.4404 (316L) |
| 14 | Seat seal | PTFE, PEEK (optional), NBR (optional), FKM (optional) |
| 15 | Valve body | Stainless steel CF3M |
Actuator

| Nominal diameter (port connection) | Actuator size Ø | Ø A | B/H | K | P |
|---|---|---|---|---|---|
| DN | NPS | ||||
| 10 | 3/8 | 32 (B) | 36.4 | 89.4 | 8.6 |
| 15 | 1/2 | 50 (D) | 55 | 154 | 11 |
| 20 | 3/4 | 50 (D) | 55 | 157 | 11 |
| 25 | 1 | 50 (D) | 55 | 169 | 11 |
| 32 | 1 1/4 | 70 (M) | 75 | 193 | 11 |
| 40 | 1 1/2 | 90 (N) | 96 | 242 | 14 |
| 50 | 2 | 130 (P) | 137 | 301 | 14 |
(Note: Dimensions in mm. The dimensions for B, H and K are maximum dimensions and may be up to 6 mm less, depending on the connection orifice size and standard.)
DANGER
Risk of injury from high pressure in the system. Before working on the system or device, switch off the pressure and vent or empty the lines.
NOTE
Damage to the seat seal or seat contour. When removing or installing the actuator, or when rotating the actuator, the valve must be in the open position.