Skip to content
JIS 10K FFDuctile Cast Iron1.4 MPa300°C

Yoshitake GLV-10F Globe Valve JIS 10K Ductile Cast Iron

Yoshitake GLV-10F is a JIS 10K ductile cast iron globe valve suitable for steam, air, water, and oil. Features 1.4 MPa max pressure and 300°C max temperature.

Yoshitake GLV-10F Globe Valve JIS 10K Ductile Cast Iron

Yoshitake GLV-10F is a ductile cast iron globe valve designed for reliable operation with steam, air, cold and hot water, oil, and other non-dangerous fluids. This page primarily covers the GLV-10F (JIS 10K), while also detailing specifications for the related GLV-20F (JIS 20K) series.

Specification

ModelGLV-10FGLV-20F
ApplicationSteam, Air, cold and hot water, oil, other non-dangerous fluid
Nominal Size15A-50A
Maximum pressure1.4 MPa *12.8 MPa *1
Maximum temperature300°C *1300°C *1
MaterialBodyDuctile cast iron
BonnetDuctile cast iron
ValveSUS403SUS304+Stellite
ConnectionJIS 10KFFJIS 20KRF

INFO

*1 The relation between pressure and temperature depend on P.2-3 JIS B 2051, pressure-temperature standard. Valve is closed at the time of shipment from the factory.

Dimensions (mm) and Weights (kg)

GLV-10F

Nominal SizedD1LHIWeights (kg)
15A158310812662.1
20A2010511713572.6
25A2511212715084.1
32A3213214016295.6
40A40132165183116.8
50A50132203186139.1

GLV-20F

Nominal SizedD1LHIWeights (kg)
15A158311012662.2
20A2010512013572.8
25A2511213015084.2
32A3213216016295.8
40A40132180183116.9
50A50180230186139.8

Yoshitake GLV-10F cross-section dimensions

Yoshitake GLV-10F dimensions diagram

Storage and Installation

Storage and Installation

(1) Keep products indoors in a well-ventilated area with minimal dust and moisture. (2) Installation must be carried out by skilled professionals using proper protective equipment. (3) Ensure correct flow direction according to the arrow marked on the product. (4) Align the piping straight with the product axis to prevent excessive stress. (5) During transport and storage, gasket stress relaxation may cause the large nut to loosen. Always retighten the large nut before use. (6) If freezing is possible, take anti-freezing measures and drain after use.

Operating Hazard

Confirm that releasing fluid to the pipe end will not cause danger before allowing fluid flow. Fluid release may cause material damage.

Operation

Operation

(1) When fully open, turn the handle back by 45 degrees to prevent it from getting stuck. (2) Do not use excessive force when opening/closing. Operate within specified torque limits. (3) Do not turn the valve further in the open/close direction when it is already fully open or fully closed.

Troubleshooting

ConditionCauseCountermeasure
External leakage1. Large nut insufficiently tightened
2. Gland packing damaged
3. Valve stem damaged
1. Retighten the large nut
2. Replace product
3. Replace product
Leakage at body/seat when fully closed1. Body or seat damaged
2. Foreign matter trapped
1. Replace product
2. Remove foreign matter
Abnormally large handle operating torque1. Large nut overtightened
2. Foreign matter in stem threads
1. Loosen the nut and retighten until leakage stops
2. Remove foreign matter
Abnormal noise1. Loose threaded parts1. Retighten

Maintenance

Maintenance Safety

Before inspection, completely release internal pressure from the product and piping. For high-temperature fluids, wait until the product cools down enough to touch bare-handed to prevent burns.

Perform annual periodic inspections to maintain function and performance:

  • Confirm normal opening/closing operation
  • Check for abnormal noise
  • Check for external leakage

Dimensional Drawing

SizedD1LHlFlange JIS 10K FFWeight(kg)
DCtn-h
15A158310812669570134-152.1
20A20105117135710075154-152.6
25A25112127150812590154-194.1
32A321321401629135100174-195.6
40A4013216518311140105174-196.8
50A5013220318613155120174-199.1

Yoshitake GLV-10F dimensional drawing

Yoshitake Isolation Valves / Globe Valves

GLV, BSV, FV, and HV series globe valves for threaded and flanged isolation duties.