Armstrong 9000 Series Conditioned-Steam Showers are designed to create a stratum of high humidity in close proximity to a fast-moving sheet or film. The objective may be to prevent the accumulation of troublesome static electricity, or the shower may be used to prevent the loss of moisture from the sheet or film.
If the sheet or film is hot, as it very likely may be, it tends to give up its moisture very quickly. A properly sized and installed steam shower creates a laminar zone of high humidity adjacent to the sheet or film, preventing this loss to maintain the desired moisture content. In virtually all applications, it is essential that the steam be discharged in a "dry" state—that is, with no water droplets or liquid spray. The unique design of Armstrong Steam Showers assures this dry discharge.

Separator-control units are identical in design and operation to equivalent humidifier models. The distribution manifolds have been especially modified to operate under slight pressure to meet the specific requirements of steam shower service. Electrically controlled and pneumatically controlled models are offered in two sizes.
The complete 9000 Series package includes the following components:
Maintenance Accessibility
Steam humidifiers (or other products) should be installed in locations that allow routine inspection and accessibility for maintenance operations. Armstrong recommends that steam humidifiers not be placed in locations where unusual instances of malfunction of the humidifiers or the systems might cause damage to nonrepairable, unreplaceable, or priceless property.
| Model No. | Control Type | Shipping Wt. (lbs)* | Inlet & Strainer Size | Drain Connection Size | Drain Trap No. | Trap Connection Size |
|---|---|---|---|---|---|---|
| DSA-91-SM | Electrical | 26 | 1/2" | 1" | 800 | 3/4" |
| DSA-92-SM | Electrical | 33 | 3/4" | 1" | 800 | 3/4" |
| AM-91-SM | Pneumatic | 32 | 1/2" | 1" | 800 | 3/4" |
| AM-92-SM | Pneumatic | 38 | 3/4" | 1" | 800 | 3/4" |
*Weight less manifold. Full nomenclature includes the length of the manifold in feet as a suffix to the Model No. 120V/60Hz is standard for electrical models; other voltages available.
| Manifold Model No. | Length (Inches) | Shipping Wt. (91 size, lbs) | Shipping Wt. (92 size, lbs) |
|---|---|---|---|
| SM-1 | 12 | 3 | 6 |
| SM-1.5 | 18 | 4 | 7 |
| SM-2 | 24 | 5 | 8 |
| SM-3 | 36 | 6 | 11 |
| SM-4 | 48 | 8 | 13 |
| SM-5 | 60 | 10 | 15 |
| SM-6 | 72 | 11 | 17 |
| SM-7 | 84 | — | 20 |
| SM-8 | 96 | — | 23 |
| SM-9 | 108 | — | 25 |
| SM-10 | 120 | — | 27 |
| SM-11 | 132 | — | 29 |
| SM-12 | 144 | — | 31 |
| Series Model | Inlet Size (NPT) | Drain Size (NPT) | Trap Connection Size (NPT) |
|---|---|---|---|
| 9090 | 1/2" | 1" | 1/2" |
| 9091 | 1/2" | 1" | 3/4" |
| 9092 | 3/4" | 1" | 3/4" |
| 9093 | 1-1/4" | 1-1/4" | 3/4" |
| 9094 | 2" | 2" | 3/4" |