BURKert 134248 (Type 6013) is a direct-acting 2/2-way plunger solenoid valve (DN 2.0-6.0) featuring a vibration-proof bolted coil system and high leak-tightness.

BURKERT 134248 (Type 6013) is a direct-acting and compact 2/2-way plunger valve up to DN 6.0. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness. A variety of seal material combinations are available to suit different applications. A Bürkert-specific flange variant (SFB) enables the space-saving arrangement of valves on a multiple manifold. Kick and drop coils are available to reduce electrical power consumption during operation.

| Product properties | Description |
|---|---|
| Material | |
| Seal | FKM, PTFE/Graphite (EPDM on request) |
| Body | Brass, stainless steel 1.4305/303 |
| Coil | Polyamide, epoxy |
| Orifice | DN 2.0...DN 6.0 |
| Circuit function | A and B |
| Thermal insulation class of solenoid coil | Polyamide coil class B, Epoxy coil class H |
| Performance data | |
| Duty cycle/single valve with block assembly on manifold | 100% continuous operation. Intermittent operation 60% (30 min) or with 5 W coil (on request) |
| Electrical data | |
| Operating voltage | 24 V DC, 24 V 50 Hz, 24 V 60 Hz, 120 V 50 Hz, 230 V 50 Hz, 240 V 60 Hz |
| Voltage tolerance | ±10% |
| Medium data | |
| Operating medium | Technical vacuum, neutral gases and liquids (e.g. compressed air, water, hydraulic oil) |
| Medium temperature (With FKM) | -10 °C...+100 °C (PA coil), -10 °C...+120 °C (Epoxy coil), -40 °C on request |
| Medium temperature (With PTFE/Graphite) | -40 °C...+180 °C |
| Medium temperature (With FKM, circuit function B) | -10 °C...+100 °C (AC), -10 °C...+120 °C (DC) |
| Viscosity | Max. 21 mm²/s |
| Product connections | |
| Electrical connection | Plug contacts according to DIN EN 175 301 - 803 form A for cable plug Type 2518 or Type 2509. ATEX/IECEx variant with 3 m moulded cable or terminal cable |
| Port connection | G 1/8, G 1/4, G 3/8, NPT 1/8, NPT 1/4, NPT 3/8, manifold (SFB) |
| Approvals and conformities | |
| Degree of protection | IP65 with cable plug |
| Environment and installation | |
| Installation position | As required, preferably with actuator upright |
| Ambient temperature | Max. +55 °C (higher temperatures on request) |
This variant is particularly suitable for switching from extremely pure gaseous medium. All medium-affected parts are submitted to additional purification processes, so that the medium is not contaminated under any circumstances. The tightness test takes place at the Helium leak detector from a min. of 10⁻⁴ mbar l/sec.
| Product properties | Description |
|---|---|
| Material | |
| Seal | Silicon, oil and fat free variant. Tightness < 10⁻⁴ mbar l/s |
| Body | Brass, stainless steel 1.4305/303 |
| Medium data | |
| Operating medium | Neutral medium, which does not attack the body and seal materials |
| Environment and installation | |
| Installation instructions | No oils, fats or silicone to be used during installation. |
The solenoid valve Type 6013 DVGW is primarily intended as an automatic safety shut-off valve for fuel gases. A strainer is installed in the inlet of the valve.
| Product properties | Description |
|---|---|
| Material | |
| Seal | NBR |
| Body | Brass, stainless steel 1.4305/303 |
| Circuit function | A |
| Performance data | |
| Operating pressure | Max. 0...5 bar |
| Medium data | |
| Operating medium | Fuel gases (e.g. town gas, district gas, liquid gas) |
| Medium temperature | -20 °C...+80 °C |
| Approvals and conformities | |
| Standards | DIN EN 161:2013, DIN EN 13611:2016 |
| Environment and installation | |
| Ambient temperature | -20 °C...+55 °C |
| Circuit Function | Description |
|---|---|
| A (CF A) | 2/2-way solenoid valve, Direct-acting, Normally closed |
| B (CF B) | 2/2-way solenoid valve, Direct-acting, Normally open |
General Notes
The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the product complies with all required specifications. Not all available variants can be supplied with the below mentioned approvals or conformities.
| Approval | Description |
|---|---|
| ATEX / IECEx (Category 2) | Optional: Explosion protection according to category 2 (zone 1/21). Coils with cable outlet: ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db Coils with terminal box: ATEX: EPS 18 ATEX 1232 X II 2G Ex eb mb IIC T4 Gb, II 2D Ex mb tb IIIC T130 °C Db IECEx: IECEx EPS 18.0110 X Ex eb mb IIC T4 Gb, Ex mb tb IIIC T130 °C Db |
| ATEX / IECEx (Category 3) | Optional: Explosion protection according to category 3 (zone 2/22). Coil with plug contacts form A and cable plug Type 2509: ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db |
| Approval | Description |
|---|---|
| UL Listed | Optional: UL Listed for the USA (valid for valves) according to UL 429 (electrically operated valves) |
| UL Hazardous Locations | Optional: UL Hazardous Locations – Explosion Protection (valid for coils). UL Listed for Hazardous Locations for USA and Canada: Class I, Zone 1; Class I, Division 2, Group A, B, C and D; Class II + III, Division 2, Group F and G |
| UL Recognized | Optional: UL Recognized for the USA (valid for valves) according to UL 429 |
| CSA | Optional: CSA for Canada (valid for valves) according to CSA 139 |
| FM (Factory Mutual) | Optional: FM (Factory Mutual) – Explosion Protection (valid for coils). FM for Hazardous Locations for USA and Canada: Class I, Zone 1; Class I, Division 1, Groups A, B, C and D; Class II + III, Division 1, Groups E, F and G |
| Conformity | Description |
|---|---|
| Drinking Water | Suitable for use in drinking water applications. The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV). PA body (PF36): Suitable for products with a maximum temperature of + 60 °C (warm water). PPS/brass/stainless steel body (PF39): Suitable for products with a maximum temperature of + 85 °C (hot water). |
| FDA | FDA – Code of Federal Regulations (valid for the variable code PL02, PL03). All wetted materials are compliant with the Code of Federal Regulations published by the FDA. |
| USP | United States Pharmacopeial Convention (USP) (valid for the variable code PL04). All wetted materials are biocompatible. |
| EC 1935/2004 | EC Regulation 1935/2004 of the European Parliament and of the Council (valid for the variable code PL01, PL02). |

| No. | Element | Material |
|---|---|---|
| 1 | Stopper | Stainless steel 1.4105/430F |
| 2 | Shading ring | Cu (brass variant), Ag (stainless steel variant) |
| 3 | Spring | Stainless steel 1.4310/301 |
| 4 | Magnetic core | Stainless steel 1.4105/430F |
| 5 | Core guide tube | Stainless steel 1.4303/305/308 |
| 6 | Seal | FKM, Graphite (high temperature variant) |
| 7 | Armature seal | FKM, PTFE |
| 8 | Valve body | Brass, Stainless steel 1.4305/303 |
| 9 | Sub-base | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant) |
| 10 | Cover | Polyamide |
| 11 | Coil | PA (polyamide), Epoxy |
| 12 | Nut | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant) |
| No. | Element | Material |
|---|---|---|
| 1 | Nut | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant) |
| 2 | Stopper | Stainless steel 1.4105/430F |
| 3 | Shading ring | Cu (brass variant), Ag (stainless steel variant) |
| 4 | Spring | Stainless steel 1.4310/301 |
| 5 | Magnetic core | Stainless steel 1.4105/430F |
| 6 | Core guide tube | Stainless steel 1.4303/305/308 |
| 7 | Seal | FKM, Graphite (high temperature variant) |
| 8 | Armature seal | FKM, PTFE (high temperature variant) |
| 9 | Valve body | Brass, Stainless steel 1.4305/303 |
| 10 | Sub-base | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant) |
| 11 | Cover | Polyamide |
| 12 | Coil | Epoxy |
| No. | Element | Material |
|---|---|---|
| 1 | Terminal box | Aluminium |
| 2 | Nut | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant) |
| 3 | Stopper | Stainless steel 1.4105/430F |
| 4 | Coil | Epoxy |
| 5 | Shading ring | Cu (brass variant), Ag (stainless steel variant) |
| 6 | Spring | Stainless steel 1.4310/301 |
| 7 | Magnetic core | Stainless steel 1.4105/430F |
| 8 | Core guide tube | Stainless steel 1.4303/305/308 |
| 9 | Cover | Polyamide |
| 10 | Sub-base | Steel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant) |
| 11 | Seal | FKM, Graphite (high temperature variant) |
| 12 | Armature seal | FKM, PTFE (high temperature variant) |
| 13 | Valve body | Brass, Stainless steel 1.4305/303 |
INFO
Dimensions in mm.

| Port connection | A [inch] | B [mm] | C [mm] | D [mm] | G [mm] |
|---|---|---|---|---|---|
| Thread | G/NPT 1/8 | 32 | 20.8 | 32.6 | 8 |
| Thread | G/NPT 1/4 | 46 | 26.8 | 49 | 12 |
| Thread | G/NPT 3/8 | 50 | 39.8 | 38 | 12 |
| Flange | - | 32 | 14.3 | 32.6 | - |
| Coil size | E [mm] | F [mm] |
|---|---|---|
| 5 | 32 | 45 |
| 6 | 40 | 51 |
INFO
Dimensions in mm.

| Port connection | A [inch] | B [mm] | C [mm] | D [mm] | G [mm] |
|---|---|---|---|---|---|
| Thread | G/NPT 1/8 | 32 | 20.8 | 32.6 | 8 |
| Thread | G/NPT 1/4 | 46 | 26.8 | 49 | 12 |
| Thread | G/NPT 3/8 | 50 | 39.8 | 38 | 12 |
| Flange | - | 32 | 14.3 | 32.6 | - |
| Coil size | E [mm] | F [mm] |
|---|---|---|
| 5 | 32 | 46 |
| 6 | 40 | 52 |
INFO
Dimensions in mm.

| Port Connection | A [inch] | B [mm] | C [mm] | D [mm] | H [mm] |
|---|---|---|---|---|---|
| Thread | G/NPT 1/8 | 32 | 20.8 | 32.6 | 8 |
| Thread | G/NPT 1/4 | 46 | 26.8 | 49 | 12 |
| Thread | G/NPT 3/8 | 50 | 39.8 | 38 | 12 |
| Flange | - | 32 | 14.3 | 32.6 | - |
| Coil size | E [mm] | F [mm] |
|---|---|---|
| 5 | 32 | 44 |
| 6 | 40 | 51 |
Circuit function A
| Orifice [mm] | Power consumption | Inrush AC [VA] | Hold AC [VA] | Coil size | Opening [ms] | Closing [ms] |
|---|---|---|---|---|---|---|
| 2.0 | 8 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 2.5 | 8 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 3.0 | 8 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 3.0 | 10 W AC or 10 W DC (11) | 30 | 22 | 6 (40 mm) | 20 | 30 |
| 4.0 | 8 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 4.0 | 10 W AC or 10 W DC (11) | 30 | 22 | 6 (40 mm) | 20 | 30 |
| 6.0 | 8 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 6.0 | 10 W AC or 10 W DC (11) | 30 | 22 | 6 (40 mm) | 20 | 30 |
(The values in brackets correspond to a coil temperature of + 20 °C.)
Circuit function B
| Orifice [mm] | Power consumption | Inrush AC [VA] | Hold AC [VA] | Coil size | Opening [ms] | Closing [ms] |
|---|---|---|---|---|---|---|
| 2.00 | 7 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 3.00 | 7 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 4.00 | 7 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
| 6.00 | 7 W AC or 8 W DC (9) | 24 | 17 | 5 (32 mm) | 20 | 30 |
(The values in brackets correspond to a coil temperature of + 20 °C.)
Control for impulse variant with polarity reversal control
Use cable plug without electrical wiring exclusively for impulse variant. Pulse duration min. 50 ms.
| Polarity (is marked on the coil with a label) | Features | Terminal connections |
|---|---|---|
| - switch ON + | valve open | (+) on terminal 2 and (-) on terminal 1 |
| + switch OFF - | valve closed | (+) on terminal 1 and (-) on terminal 2 |
Explore similar products in our catalog