Skip to content
Direct-actingUp to DN 6.0Vibration-proofIP65

BURKERT 134248 (Type 6013) Direct-acting 2/2-way Plunger Valve

BURKert 134248 (Type 6013) is a direct-acting 2/2-way plunger solenoid valve (DN 2.0-6.0) featuring a vibration-proof bolted coil system and high leak-tightness.

BURKERT 134248 (Type 6013) Direct-acting 2/2-way Plunger Valve

BURKERT 134248 (Type 6013) is a direct-acting and compact 2/2-way plunger valve up to DN 6.0. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness. A variety of seal material combinations are available to suit different applications. A Bürkert-specific flange variant (SFB) enables the space-saving arrangement of valves on a multiple manifold. Kick and drop coils are available to reduce electrical power consumption during operation.

BURKERT 134248 (Type 6013) direct-acting 2/2-way plunger valve

General Technical Data

Standard Variant

Product propertiesDescription
Material
SealFKM, PTFE/Graphite (EPDM on request)
BodyBrass, stainless steel 1.4305/303
CoilPolyamide, epoxy
OrificeDN 2.0...DN 6.0
Circuit functionA and B
Thermal insulation class of solenoid coilPolyamide coil class B, Epoxy coil class H
Performance data
Duty cycle/single valve with block assembly on manifold100% continuous operation. Intermittent operation 60% (30 min) or with 5 W coil (on request)
Electrical data
Operating voltage24 V DC, 24 V 50 Hz, 24 V 60 Hz, 120 V 50 Hz, 230 V 50 Hz, 240 V 60 Hz
Voltage tolerance±10%
Medium data
Operating mediumTechnical vacuum, neutral gases and liquids (e.g. compressed air, water, hydraulic oil)
Medium temperature (With FKM)-10 °C...+100 °C (PA coil), -10 °C...+120 °C (Epoxy coil), -40 °C on request
Medium temperature (With PTFE/Graphite)-40 °C...+180 °C
Medium temperature (With FKM, circuit function B)-10 °C...+100 °C (AC), -10 °C...+120 °C (DC)
ViscosityMax. 21 mm²/s
Product connections
Electrical connectionPlug contacts according to DIN EN 175 301 - 803 form A for cable plug Type 2518 or Type 2509. ATEX/IECEx variant with 3 m moulded cable or terminal cable
Port connectionG 1/8, G 1/4, G 3/8, NPT 1/8, NPT 1/4, NPT 3/8, manifold (SFB)
Approvals and conformities
Degree of protectionIP65 with cable plug
Environment and installation
Installation positionAs required, preferably with actuator upright
Ambient temperatureMax. +55 °C (higher temperatures on request)

Analytical Variant

This variant is particularly suitable for switching from extremely pure gaseous medium. All medium-affected parts are submitted to additional purification processes, so that the medium is not contaminated under any circumstances. The tightness test takes place at the Helium leak detector from a min. of 10⁻⁴ mbar l/sec.

Product propertiesDescription
Material
SealSilicon, oil and fat free variant. Tightness < 10⁻⁴ mbar l/s
BodyBrass, stainless steel 1.4305/303
Medium data
Operating mediumNeutral medium, which does not attack the body and seal materials
Environment and installation
Installation instructionsNo oils, fats or silicone to be used during installation.

DVGW Variant

The solenoid valve Type 6013 DVGW is primarily intended as an automatic safety shut-off valve for fuel gases. A strainer is installed in the inlet of the valve.

Product propertiesDescription
Material
SealNBR
BodyBrass, stainless steel 1.4305/303
Circuit functionA
Performance data
Operating pressureMax. 0...5 bar
Medium data
Operating mediumFuel gases (e.g. town gas, district gas, liquid gas)
Medium temperature-20 °C...+80 °C
Approvals and conformities
StandardsDIN EN 161:2013, DIN EN 13611:2016
Environment and installation
Ambient temperature-20 °C...+55 °C

Circuit Functions

Circuit FunctionDescription
A (CF A)2/2-way solenoid valve, Direct-acting, Normally closed
B (CF B)2/2-way solenoid valve, Direct-acting, Normally open

Approvals and Conformities

General Notes

The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the product complies with all required specifications. Not all available variants can be supplied with the below mentioned approvals or conformities.

Explosion Protection

ApprovalDescription
ATEX / IECEx (Category 2)Optional: Explosion protection according to category 2 (zone 1/21).
Coils with cable outlet:
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db
IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db
Coils with terminal box:
ATEX: EPS 18 ATEX 1232 X II 2G Ex eb mb IIC T4 Gb, II 2D Ex mb tb IIIC T130 °C Db
IECEx: IECEx EPS 18.0110 X Ex eb mb IIC T4 Gb, Ex mb tb IIIC T130 °C Db
ATEX / IECEx (Category 3)Optional: Explosion protection according to category 3 (zone 2/22).
Coil with plug contacts form A and cable plug Type 2509:
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db
IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db

North America (USA/Canada)

ApprovalDescription
UL ListedOptional: UL Listed for the USA (valid for valves) according to UL 429 (electrically operated valves)
UL Hazardous LocationsOptional: UL Hazardous Locations – Explosion Protection (valid for coils). UL Listed for Hazardous Locations for USA and Canada: Class I, Zone 1; Class I, Division 2, Group A, B, C and D; Class II + III, Division 2, Group F and G
UL RecognizedOptional: UL Recognized for the USA (valid for valves) according to UL 429
CSAOptional: CSA for Canada (valid for valves) according to CSA 139
FM (Factory Mutual)Optional: FM (Factory Mutual) – Explosion Protection (valid for coils). FM for Hazardous Locations for USA and Canada: Class I, Zone 1; Class I, Division 1, Groups A, B, C and D; Class II + III, Division 1, Groups E, F and G

Drinking Water & Hygiene

ConformityDescription
Drinking WaterSuitable for use in drinking water applications. The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV).
PA body (PF36): Suitable for products with a maximum temperature of + 60 °C (warm water).
PPS/brass/stainless steel body (PF39): Suitable for products with a maximum temperature of + 85 °C (hot water).
FDAFDA – Code of Federal Regulations (valid for the variable code PL02, PL03). All wetted materials are compliant with the Code of Federal Regulations published by the FDA.
USPUnited States Pharmacopeial Convention (USP) (valid for the variable code PL04). All wetted materials are biocompatible.
EC 1935/2004EC Regulation 1935/2004 of the European Parliament and of the Council (valid for the variable code PL01, PL02).

Materials

Standard Variant

BURKERT 134248 (Type 6013) standard variant material specifications

No.ElementMaterial
1StopperStainless steel 1.4105/430F
2Shading ringCu (brass variant), Ag (stainless steel variant)
3SpringStainless steel 1.4310/301
4Magnetic coreStainless steel 1.4105/430F
5Core guide tubeStainless steel 1.4303/305/308
6SealFKM, Graphite (high temperature variant)
7Armature sealFKM, PTFE
8Valve bodyBrass, Stainless steel 1.4305/303
9Sub-baseSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant)
10CoverPolyamide
11CoilPA (polyamide), Epoxy
12NutSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant)

ATEX/IECEx Cable Variant

No.ElementMaterial
1NutSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant)
2StopperStainless steel 1.4105/430F
3Shading ringCu (brass variant), Ag (stainless steel variant)
4SpringStainless steel 1.4310/301
5Magnetic coreStainless steel 1.4105/430F
6Core guide tubeStainless steel 1.4303/305/308
7SealFKM, Graphite (high temperature variant)
8Armature sealFKM, PTFE (high temperature variant)
9Valve bodyBrass, Stainless steel 1.4305/303
10Sub-baseSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant)
11CoverPolyamide
12CoilEpoxy

ATEX/IECEx Terminal Box Variant

No.ElementMaterial
1Terminal boxAluminium
2NutSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant)
3StopperStainless steel 1.4105/430F
4CoilEpoxy
5Shading ringCu (brass variant), Ag (stainless steel variant)
6SpringStainless steel 1.4310/301
7Magnetic coreStainless steel 1.4105/430F
8Core guide tubeStainless steel 1.4303/305/308
9CoverPolyamide
10Sub-baseSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant)
11SealFKM, Graphite (high temperature variant)
12Armature sealFKM, PTFE (high temperature variant)
13Valve bodyBrass, Stainless steel 1.4305/303

Dimensions

Standard Variant

INFO

Dimensions in mm.

BURKERT 134248 (Type 6013) standard variant dimensions

Port connectionA [inch]B [mm]C [mm]D [mm]G [mm]
ThreadG/NPT 1/83220.832.68
ThreadG/NPT 1/44626.84912
ThreadG/NPT 3/85039.83812
Flange-3214.332.6-
Coil sizeE [mm]F [mm]
53245
64051

ATEX/IECEx Cable Variant

INFO

Dimensions in mm.

BURKERT 134248 (Type 6013) ATEX/IECEx cable variant dimensions

Port connectionA [inch]B [mm]C [mm]D [mm]G [mm]
ThreadG/NPT 1/83220.832.68
ThreadG/NPT 1/44626.84912
ThreadG/NPT 3/85039.83812
Flange-3214.332.6-
Coil sizeE [mm]F [mm]
53246
64052

ATEX/IECEx Terminal Box Variant

INFO

Dimensions in mm.

BURKERT 134248 (Type 6013) ATEX/IECEx terminal box variant dimensions

Port ConnectionA [inch]B [mm]C [mm]D [mm]H [mm]
ThreadG/NPT 1/83220.832.68
ThreadG/NPT 1/44626.84912
ThreadG/NPT 3/85039.83812
Flange-3214.332.6-
Coil sizeE [mm]F [mm]
53244
64051

Performance Specifications

Power Consumption

Circuit function A

Orifice [mm]Power consumptionInrush AC [VA]Hold AC [VA]Coil sizeOpening [ms]Closing [ms]
2.08 W AC or 8 W DC (9)24175 (32 mm)2030
2.58 W AC or 8 W DC (9)24175 (32 mm)2030
3.08 W AC or 8 W DC (9)24175 (32 mm)2030
3.010 W AC or 10 W DC (11)30226 (40 mm)2030
4.08 W AC or 8 W DC (9)24175 (32 mm)2030
4.010 W AC or 10 W DC (11)30226 (40 mm)2030
6.08 W AC or 8 W DC (9)24175 (32 mm)2030
6.010 W AC or 10 W DC (11)30226 (40 mm)2030

(The values in brackets correspond to a coil temperature of + 20 °C.)

Circuit function B

Orifice [mm]Power consumptionInrush AC [VA]Hold AC [VA]Coil sizeOpening [ms]Closing [ms]
2.007 W AC or 8 W DC (9)24175 (32 mm)2030
3.007 W AC or 8 W DC (9)24175 (32 mm)2030
4.007 W AC or 8 W DC (9)24175 (32 mm)2030
6.007 W AC or 8 W DC (9)24175 (32 mm)2030

(The values in brackets correspond to a coil temperature of + 20 °C.)

Product Installation

Installation Notes

Control for impulse variant with polarity reversal control

Use cable plug without electrical wiring exclusively for impulse variant. Pulse duration min. 50 ms.

Polarity (is marked on the coil with a label)FeaturesTerminal connections
- switch ON +valve open(+) on terminal 2 and (-) on terminal 1
+ switch OFF -valve closed(+) on terminal 1 and (-) on terminal 2