Burkert Type 3320 electromotive 2/2-way angle seat on/off valve. Features 0-25 bar operating pressure, 24 V DC supply, IP65/IP67 protection, and DN 15 to DN 80 connections.

Burkert Type 3320 electromotive 2/2-way angle seat valve operates as an on/off valve for shut-off tasks under demanding operating conditions. The electromotive actuator features a ball screw that moves the swivel plate at speeds up to 6 mm/s, reacting almost instantaneously to process signals. The valve provides a safety position via an optional SAFEPOS energy-pack in the event of a power failure. The closed design and powder-coated aluminium actuator housing provide IP65/IP67 and NEMA 4X protection, ensuring resistance to impact and vibration. The valve utilizes a self-adjusting packing gland with exchangeable V-seals to maximize service life and tightness. The fieldbus-compatible Type 3320 supports EtherNet/IP, PROFINET, Modbus TCP, and EtherCAT for process monitoring and valve diagnostics.
Actuator Sizes
| Product Properties | Specification |
|---|---|
| Design | Angle seat on/off valve |
| Nominal diameter | DN 15...DN 80, NPS 1/2...3 |
| Safety setting (power failure) | With SAFEPOS energy-pack: open, closed or freely programmable. Without: blocked in last position |
| Flow direction | Against closing direction (below seat) |
| Operating pressure | 0...25 bar(g). Vacuum variant: -0.9 bar(g) |
| Nominal pressure | PN 25 (DIN EN 1333), Class 150 (DIN EN 1759) |
| Seat leakage | Leakage rate A (DIN EN 12266-1), seat seal PTFE and PEEK, test medium air |
| Kv value | 5.0...140 m³/h |
| Closing time | AG2: 2.3...6.6 s. AG3: 8.7 s |
| Travel speed | 6 mm/s (AG2 1300 N), 4 mm/s (AG2 2500 N), 3 mm/s (AG3 7700/10000 N) |
| Operating voltage | 24 V DC ± 10 % (maximum residual ripple 10 %) |
| Operating current | AG2: max 3 A. AG3: max 5 A (including charging current of SAFEPOS) |
| Duty cycle | 100 % |
| Fieldbus (digital) | Bürkert system bus (büS), CANopen, EtherNet/IP, PROFINET, Modbus TCP, EtherCAT |
| Operating medium | Steam, neutral gases, water, alcohols, oils, fuels, hydraulic fluids, salt solutions, lyes, organic solvents, oxygen (optional) |
| Medium temperature | -40...+ 230 °C |
| Ambient temperature | -25...+ 65 °C (without additional modules) |
| Degree of protection | IP65/IP67 (DIN EN 60529), NEMA 4X |
| Component | AG2 Material | AG3 Material |
|---|---|---|
| Blind cover/gateway housing | PPS (standard), stainless steel 1.4301 (ATEX/IECEx) | PPS (standard), stainless steel 1.4301 (ATEX/IECEx) |
| Actuator cover | PPS | PC |
| Seal | EPDM | EPDM |
| Actuator housing | Powder-coated aluminium | Powder-coated aluminium |
| Actuator base | PPS | Stainless steel 1.4308 |

| No. | Component | Material |
|---|---|---|
| 1 | Spindle | Stainless steel 1.4401 (316) / 1.4404 (316L) |
| 2 | Spindle seal | PTFE V-seals (filled) with spring compensation |
| 3 | Spindle guide | PEEK or stainless steel 1.4404 (316L) |
| 4 | Packing gland tube | Stainless steel 1.4401 (316) |
| 5 | Seal valve body | Graphite or PTFE |
| 6 | Swivel plate | Stainless steel 1.4401 (316) / 1.4404 (316L) |
| 7 | Valve seat seal | PTFE or PEEK sealing washer |
| 8 | Valve body | Stainless steel CF3M |
AG2 Actuator
AG3 Actuator
Threaded Connection
Welded Connection
Clamp Connection
| DN | NPS | Actuator force [N] | Max. operating pressure [bar(g)] | Kv value water [m³/h] (Welded ISO 4200) |
|---|---|---|---|---|
| 15 | 1/2 | 1300 | 25 | 5.4 |
| 20 | 3/4 | 1300 | 11 | 11 |
| 25 | 1 | 1300 | 20 | 20 |
| 32 | 1 1/4 | 1300 / 2500 | 16 / 25 | 32 |
| 40 | 1 1/2 | 1300 / 2500 / 7700 | 10 / 18 / 25 | 47 |
| 50 | 2 | 1300 / 2500 / 7700 | 6 / 10 / 25 | 62 |
| 65 | 2 1/2 | 10000 | 25 | 91 |
| 80 | 3 | 10000 | 17 | 140 |
PTFE is used for a maximum medium temperature of +130 °C. If the maximum medium temperature temporarily or permanently exceeds +130 °C, PEEK is the appropriate seal material.


Risk of injury from high pressure
Before working on the system or device, switch off the pressure and vent or drain lines.
Risk of injury if the wrong tools are used
To remove the actuator from the valve body, use an open-end wrench, never a pipe wrench. To replace the packing gland, use a special installation wrench, modified socket wrench, or open-end wrench.
When removing the actuator from the valve body, ensure that the valve is in the open position. The control valve can be manually opened electrically or mechanically. Do not exceed the maximum tightening torque of 2 Nm when using the mechanical manual control.
Grease the external thread of the body connection (e.g., with Klüber paste UH1 96-402). Screw the actuator onto the valve body using an open-end wrench.
| Connection size valve body DN [mm] | Tightening torques [Nm] |
|---|---|
| 13, 15 | 45 ±3 |
| 20 | 50 ±3 |
| 25 | 60 ±3 |
| 32, 40 | 65 ±3 |
| 50 | 70 ±3 |
| 65 | 100 ±3 |
After installing the actuator, run the X.TUNE function to adjust the position controller to the physical stroke of the actuating element. Never run the X.TUNE under medium pressure.