Skip to content
DN 80Flange ConnectionStainless Steel-10°C to 230°CPN 16

BURKERT 20114631 Type 2921 Manually Operated 2/2-Way Globe Valve, DN 80 Flange

Burkert 20114631 Type 2921 manually operated 2/2-way globe valve. Features DN 80 flange connection, stainless steel body, and PTFE/PEEK seals. Suitable for media temperatures from -10°C to 230°C.

BURKERT 20114631 Type 2921 Manually Operated 2/2-Way Globe Valve, DN 80 Flange

Burkert 20114631 Type 2921 globe valve consists of a manual actuator and a 2-way body made of stainless steel. With a high-quality valve body, the manually operated valve offers diverse usage options to shut off both neutral and aggressive gaseous and liquid media. The tried-and-tested self-adjusting packing gland guarantees optimal tightness and therefore enables low-maintenance operation, even at high switching cycles. Depending on the application, the soft PTFE or PEEK seal ensures a reliable valve seat seal, even under challenging operating conditions. The actuator is made of high-quality plastic and is suitable for use in demanding environments. It possesses a visual position indicator and can be optionally equipped with stroke limitation and locking.

Burkert 20114631 Type 2921 globe valve structure

General Technical Data

Product properties
DesignGlobe valve on/off
Nominal diameterDN 10...DN 100, NPS 3/8...NPS 4
Flow directionFlow to open (below seat)
Performance data
Operating pressure0 bar(g)...25 bar(g)
Nominal pressurePN 25 (DIN EN 1333), Class 150 (DIN EN 1759)
Seat leakageLeakage rate A (DIN EN 12266-1), seat seal PTFE and PEEK, test medium air
Kv value0.1 m³/h...140 m³/h
Medium data
Operating mediumSteam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, organic solvents
Medium temperature-40 °C...+230 °C
ViscosityMax. 600 mm²/s
Environment and installation
Environmental factorsProtect the device from electromagnetic interference, UV radiation and, when used outdoors, from weather conditions.
Ambient temperature-10 °C...+60 °C
Installation positionAs required, preferably with actuator upright

Approvals and Conformities

  • Explosion protection (Optional): As a category 2 device suitable for zone 1/21 and zone 2/22. ATEX: II 2G Ex h IIC T4...T2 Gb / II 2D Ex h IIIC T135 °C...T300 °C Db. IECEx: Ex h IIC T4...T2 Gb / Ex h IIIC T135 °C...T300 °C Db.
  • Drinking water: Suitable for use in drinking water applications. The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV).
  • Foods and beverages/Hygiene: FDA – Code of Federal Regulations, United States Pharmacopeial Convention (USP), EC Regulation 1935/2004, China food GB Standards.

Materials

Burkert 20114631 Type 2921 material specifications

No.ElementMaterial
1CoverPolyamide (PA)
2ScrewStainless steel 1.4301
3Locking deviceStainless steel 1.4305
4HandwheelPolyphenylene sulphide (PPS)
5Visual position indicator with scalePolyamide (PA)
6Packing glandPTFE V-rings (filled), with spring compensation
7SpindleStainless steel 1.4401 (316)/1.4404 (316L)
8Spindle guideDN 15...DN 50: PEEK
DN 65...DN 100: Stainless steel 1.4401 (316)/1.4404 (316L)
9Housing sealGraphite
10Swivel plateStainless steel 1.4401 (316)/1.4404 (316L)
11Seat sealPTFE or PEEK
12Valve seat with O-ringStainless steel 1.4571, EPDM
13Valve bodyStainless steel 316L/CF3M

Dimensions

Actuator

Burkert 20114631 Type 2921 actuator dimensions

DNNPSHandwheel diameter ∅ [mm]H1H2 (locking)
151/245 (S)217224
203/445 (S)224230
25145 (S)228234
321 1/445 (S)296303
401 1/245 (S), 110 (M)301307
502110 (M)307313
652 1/2160 (L)361368
803160 (L)369375
1004160 (L)379385

Body with Flange Connection

Burkert 20114631 Type 2921 flange body dimensions

DN∅ DFLF∅ BFAF∅ DA x α∅ MF
15951306516144 x 90°18.1
201051507518144 x 90°23.7
251151608518144 x 90°29.7
3214018010018184 x 90°38.4
4015020011018184 x 90°44.3
5016523012520184 x 90°56.3
6518529014522188 x 45°66.0
8020031016024188 x 45°81.0
10023535019024228 x 45°100.0

(Dimensions in mm for DIN EN 1092 PN 25 FTF 1 according to DIN EN 558-1)

Performance Specifications

Fluidic Data

Overview of fluidic data for flow below seat (for liquids, steam and gases):

DNNPSHandwheel diameter ∅ [mm]Operating pressure max. PTFE [bar(g)]Operating pressure max. PEEK [bar(g)]Kv value [m³/h]
151/245 (S)25254.7
203/445 (S)25258.1
25145 (S)252513.0
321 1/445 (S)252520
401 1/245 (S), 110 (M)252531
502110 (M)25 (20)23 (20)45
652 1/2160 (L)24 (15)1473
803160 (L)1610110
1004160 (L)106165

Operating Limits for Optional Variants

  • High temperature variant: By adapting the packing gland this variant is suitable for applications with steam, neutral gases and other heat transfer mediums up to +230 °C.
  • Water variant: For applications with water up to +200 °C; a special configuration of the packing gland increases the lifetime significantly. It is recommended for all water applications.
  • Drinking water variant: The materials comply with the assessment principles (UBA) for materials in contact with drinking water up to +85 °C.
  • Low temperature variant: Suitable for minimum medium temperatures down to -40 °C.

Function and Operation

Position Indicator

Burkert 20114631 Type 2921 position indicator

When turning the handwheel anticlockwise, the reproducible stroke scale becomes visible between the position indicator and the handwheel. The scale on the handwheel determines the rotation position of the handwheel (50 positions). The reproducible stroke scale shows, depending on the bottom edge of the handwheel, the relative position of the valve (valve opening) and acts as a fixation point for determining the rotation position.

Flow Direction

The valve seat is always closed against the medium flow. The flow direction should therefore be set such that the valve reaches the flow beneath the valve seat.

Burkert 20114631 Type 2921 flow direction below seat

Set Stroke Limit

Setting the minimum and maximum stroke limit is possible as an option. An adjusting sleeve is used for this purpose.

Burkert 20114631 Type 2921 set stroke limit

  1. By turning the handwheel clockwise, the valve is moved to the closed position.
  2. Loosen the screw on the handwheel and remove handwheel.
  3. Screw adjusting sleeve clockwise until it comes to a stop. Minimum stroke is set.
  4. Mount handwheel on actuator. Move the valve to the desired maximally open position.
  5. Loosen the screw on the handwheel and remove the handwheel.
  6. Pull adjusting sleeve upwards and at the same time, screw anticlockwise until it comes to a stop. Maximum stroke is set.
  7. Mount handwheel on actuator and tighten the screw.

Lock Handwheel

It is also an option to lock the handwheel to prevent unintentional or unauthorised operation of the valve.

Burkert 20114631 Type 2921 lock handwheel

Push locking pin down and rotate by 180° (either clockwise or anticlockwise). The locking pin must lock into its end position so that the drill hole is fully visible once again. Insert padlock through the bore in the locking pin and secure.

Installation

DANGER!

Risk of injury due to high pressure and escaping medium.

  • Switch off the pressure before working on the device or system. Vent or drain the lines.

WARNING!

Risk of injury due to improper installation.

  • Installation may be carried out by authorised technicians only and with the appropriate tools.
  • Observe tightening torques.
  • Do not reach into the openings of the valve body.
  • Note the installation position. The device can be installed in any manner, preferably with the actuator facing upwards.
  • Ensure pipelines are aligned before connection.
  • Note the flow direction. The flow direction is visible on the valve body and on the type label.
  • Clear impurities from pipelines (seal material, metal chips, etc.).

Troubleshooting

FaultCauseElimination
Valve is not tightDirt between seal and valve seatInstall dirt trap
Valve seat seal wornInstall new control cone
Flow direction interchangedObserve the marking for the flow direction on the valve body
Operating pressure too highObserve pressure specifications on the type label
Valve is leaking on the relief borePacking gland wornReplacing packing gland