BURKERT 575531 (Type 8140) compact radar level transmitter delivers continuous 0–30 m measurement with PVDF NPT 1 1/2 thread, 4–20 mA HART output, Bluetooth, IP66/67 protection, and ATEX/IECEx ratings.

BURKERT 575531 (Type 8140) is a compact radar level transmitter configured for continuous liquid and bulk solids level measurement across distances from 0.00 m up to 30.00 m with 1 mm accuracy. The unit combines a PVDF sensor body and integrated antenna with an external NPT 1 1/2 process thread and FKM medium-contacting seals, rated for process pressures up to 3 bar.
Operating on a 12 to 35 V DC supply, the device delivers a standard 4–20 mA current loop output equipped with HART communication. Configuration can be performed locally through an integrated display module or wirelessly via Bluetooth interface.
| Parameter | Specification |
|---|---|
| Burkert Type | 8140 |
| Order Code (SKU) | 575531 |
| Measurement Principle | Non-contact radar |
| Measuring Range | 0.00 to 30.00 m |
| Measuring Accuracy | 1 mm |
| Measurement Mode | Continuous measurement |
| Process Connection | External thread NPT 1 1/2 |
| Connection Material Category | Plastics (PVDF) |
| Antenna Construction | Thread with integrated antenna (PVDF) |
| Wetted Seal Material | FKM (Fluor rubber) |
| Housing / Cover Seal | EPDM |
| Operating Voltage | 12.0 V to 35.0 V DC |
| Analog Output | 4–20 mA (current output HART) |
| Digital Communication | HART + Bluetooth |
| Electrical Connection | 1x M20 cable gland (Polyamide, NBR seal), clamp terminals |
| Permissible Medium Pressure | Max. 3 bar |
| Medium Temperature | -40 °C to +80 °C |
| Ambient Temperature | -40 °C to +80 °C |
| Enclosure Rating | IP66 / IP67 |
| Explosion Protection | ATEX / IECEx: II 1/2 G Ex ia IIC T6...T1 Ga/Gb |
BURKERT 575531 utilizes a compact device architecture with a wetted PVDF threaded body and integrated antenna. The NPT 1 1/2 external thread allows direct installation onto vessel nozzles or threaded tank connections without requiring separate horn extensions.
Process sealing is maintained by an FKM elastomeric seal for medium-contacting components, while housing covers and enclosure interfaces are sealed with EPDM. Wetted elements withstand process temperatures between -40 °C and +80 °C under operating pressures up to 3 bar.
The transmitter operates as a loop-powered device across an input voltage range of 12 V to 35 V DC. Process values are transmitted via an active 4–20 mA current output supporting the highway addressable remote transducer (HART) digital protocol.
Parametrisation and Commissioning
Field setup is supported through two complementary methods:
Wiring enters through a single M20 polyamide cable gland fitted with an NBR seal and terminates at internal clamp terminals. Cable plugs are not included in delivery.
BURKERT 575531 provides dual IP66 and IP67 ingress protection against heavy water spray and temporary submersion.
Hazardous Area Certifications
The instrument carries intrinsic safety approvals under both ATEX and IECEx standards for Zone 0 and Zone 1 gas atmospheres:
Ambient and process media temperatures must remain within the certified range of -40 °C to +80 °C.