Skip to content
Radar Measurement0–30 m Range4–20 mA / HARTBluetoothIP66 / IP67ATEX / IECEx

BURKERT 575531 (Type 8140) Radar Level Transmitter, 0–30 m, NPT 1 1/2

BURKERT 575531 (Type 8140) compact radar level transmitter delivers continuous 0–30 m measurement with PVDF NPT 1 1/2 thread, 4–20 mA HART output, Bluetooth, IP66/67 protection, and ATEX/IECEx ratings.

BURKERT 575531 (Type 8140) Radar Level Transmitter, 0–30 m, NPT 1 1/2

BURKERT 575531 (Type 8140) is a compact radar level transmitter configured for continuous liquid and bulk solids level measurement across distances from 0.00 m up to 30.00 m with 1 mm accuracy. The unit combines a PVDF sensor body and integrated antenna with an external NPT 1 1/2 process thread and FKM medium-contacting seals, rated for process pressures up to 3 bar.

Operating on a 12 to 35 V DC supply, the device delivers a standard 4–20 mA current loop output equipped with HART communication. Configuration can be performed locally through an integrated display module or wirelessly via Bluetooth interface.

Technical Specifications ​

ParameterSpecification
Burkert Type8140
Order Code (SKU)575531
Measurement PrincipleNon-contact radar
Measuring Range0.00 to 30.00 m
Measuring Accuracy1 mm
Measurement ModeContinuous measurement
Process ConnectionExternal thread NPT 1 1/2
Connection Material CategoryPlastics (PVDF)
Antenna ConstructionThread with integrated antenna (PVDF)
Wetted Seal MaterialFKM (Fluor rubber)
Housing / Cover SealEPDM
Operating Voltage12.0 V to 35.0 V DC
Analog Output4–20 mA (current output HART)
Digital CommunicationHART + Bluetooth
Electrical Connection1x M20 cable gland (Polyamide, NBR seal), clamp terminals
Permissible Medium PressureMax. 3 bar
Medium Temperature-40 °C to +80 °C
Ambient Temperature-40 °C to +80 °C
Enclosure RatingIP66 / IP67
Explosion ProtectionATEX / IECEx: II 1/2 G Ex ia IIC T6...T1 Ga/Gb

Process Connection and Sensor Construction ​

BURKERT 575531 utilizes a compact device architecture with a wetted PVDF threaded body and integrated antenna. The NPT 1 1/2 external thread allows direct installation onto vessel nozzles or threaded tank connections without requiring separate horn extensions.

Process sealing is maintained by an FKM elastomeric seal for medium-contacting components, while housing covers and enclosure interfaces are sealed with EPDM. Wetted elements withstand process temperatures between -40 °C and +80 °C under operating pressures up to 3 bar.

Electrical Integration and Communication ​

The transmitter operates as a loop-powered device across an input voltage range of 12 V to 35 V DC. Process values are transmitted via an active 4–20 mA current output supporting the highway addressable remote transducer (HART) digital protocol.

Parametrisation and Commissioning

Field setup is supported through two complementary methods:

  • Local configuration using the built-in display module and clamp-terminal interface.
  • Wireless parameterization using integrated Bluetooth communication without opening the transmitter housing in service environments.

Wiring enters through a single M20 polyamide cable gland fitted with an NBR seal and terminates at internal clamp terminals. Cable plugs are not included in delivery.

Operating Limits and Hazardous Area Approvals ​

BURKERT 575531 provides dual IP66 and IP67 ingress protection against heavy water spray and temporary submersion.

Hazardous Area Certifications

The instrument carries intrinsic safety approvals under both ATEX and IECEx standards for Zone 0 and Zone 1 gas atmospheres:

  • ATEX: II 1/2 G Ex ia IIC T6...T1 Ga/Gb
  • IECEx: A463 Ex ia IIC T6...T1 Ga/Gb

Ambient and process media temperatures must remain within the certified range of -40 °C to +80 °C.