Skip to content
Stainless SteelClosed TypeLift Type

Yoshitake AL-31H Safety Relief Valve 1.0-2.0 MPa

Yoshitake AL-31H lift type, closed safety relief valve in all stainless steel. Max set pressure 2.0 MPa. Ideal for steam, air, water, and oil.

Yoshitake AL-31H Safety Relief Valve 1.0-2.0 MPa

Yoshitake AL-31H is a lift type, closed safety relief valve made of all stainless steel, offering high corrosion resistance and durability. Designed to handle steam, air, cold and hot water, oil, and other non-dangerous fluids, this model can be set at a maximum pressure of 2.0 MPa.

Features

  • Safety relief valve of all stainless steel made, offering high corrosion resistance and durability in particular.
  • AL-31H can be set at Max. 2.0 MPa.

Yoshitake AL-31H safety relief valve

Specifications

ModelAL-31H
StructureClosed type *
ApplicationSteam, Air, Cold and hot water, Oil, Other non-dangerous fluids
Working pressure1.0 - 2.0 MPa
Maximum temperature220°C **
ConnectionJIS 16K RF flanged, JIS 20K RF flanged
Nominal size15 - 50A

* The structure in which the fluid is discharged only from the outlet. ** The maximum temperature is 150°C when using for water, oil, or other liquids (the fluid is liquid).

Dimensions and Weights

Nominal sizeDimension (mm) di x D x doLH1HFlow area (mm²)Weight (kg)
15A15 x 16 x 20737216020.13.4
20A20 x 21 x 25777416334.64.5
25A25 x 26 x 32918718753.06.5
32A32 x 33 x 40969223885.58.1 (8.3)
40A40 x 41 x 50114100277132.011.4 (11.7)
50A50 x 51 x 65116107315 (357)204.215.0 (18.0)
  • The above values in parentheses are the dimensions and weights of JIS 20K RF flanged.
  • Screwed connection size of the outlet side is 1 size larger than the nominal size.

Yoshitake AL-31H dimensions

Certified Capacity Table for AL-31H

For Steam (at saturated temperature)

Capacity (Pressure vessel structure standard) [kg/h]

Nominal sizeBlowout area [mm²]1.0 MPa1.1 MPa1.2 MPa1.3 MPa1.4 MPa1.5 MPa1.6 MPa1.7 MPa1.8 MPa1.9 MPa2.0 MPa
15A20.1119129139149149158168178188198207
20A34.6206222239256256273290306324340357
25A53.0315341367363393418444470496522547
32A85.5509550592634634675716758800842883
40A132.0786850914979979104211061171123613001364
50A204.212161315141415141514161217121811191220112110

For Air (at 20˚C)

Capacity (Pressure vessel structure standard) [kg/h]

Nominal sizeBlowout area [mm²]1.0 MPa1.1 MPa1.2 MPa1.3 MPa1.4 MPa1.5 MPa1.6 MPa1.7 MPa1.8 MPa1.9 MPa2.0 MPa
15A20.1181197214230247264280297313330347
20A34.6311340368397426454483511540568597
25A53.0477521565608652696740783827871915
32A85.57708419119821052112311931264133514051476
40A132.011891298140715161625173418431952206121702279
50A204.218402008217723452514268228513020318833573525

For Water (at 20˚C, accumulation: 25%)

Capacity (Yoshitake standard) [m³/h]

Nominal sizeBlowout area [mm²]1.0 MPa1.1 MPa1.2 MPa1.3 MPa1.4 MPa1.5 MPa1.6 MPa1.7 MPa1.8 MPa1.9 MPa2.0 MPa
15A20.11.11.11.21.21.31.31.41.41.51.51.6
20A34.61.92.02.12.22.32.32.42.52.62.62.7
25A53.02.93.13.23.43.53.63.73.94.04.14.2
32A85.54.85.05.25.55.75.96.16.26.46.66.8
40A132.07.47.88.18.48.89.19.49.79.910.010.5
50A204.211.512.012.613.113.614.114.515.015.415.816.3

[Example for water] When the set pressure is 2.0 MPa, and the valve size is 25A: The capacity is 4.2 m³/h, when the inlet pressure reaches 2.5 MPa (accumulation becomes 25%) after the fluid pressure reaches the set pressure of 2.0 MPa.

Operation

Yoshitake AL-31H structure

Blowout Operation

As the inlet pressure approaches the blowout pressure, the force of fluid pushing up the valve approaches the force of the spring pressing down the valve. The safety relief valve commences to blow when the inlet pressure reaches around 3% below the blowout pressure. The fluid accumulates gradually on the pressure groove and when the fluid pressure reaches the blowout pressure the valve pops.

Closing Operation

Since the inlet pressure of the safety relief valve decreases when the fluid is released into the atmosphere by the pop action of the valve, the force of fluid lift is lowered. At this point, the repelling force of the spring becomes larger than the force of fluid lift and thus the valve closes. In addition, while the safety relief valve discharges, pressure of fluid entering into the back of the valve (back pressure) adds to the closing force.

Installation

WARNING

  1. Do not install any closing device such as a stop valve at inlet or outlet sides of the product.
  2. Do not apply the product to devices which do not allow any valve seat leakage.
  3. Do not disassemble the product.
  4. Install an exhaust pipe on the outlet side of the product, and lead it to a place where there is no risk of physical damage even if fluid blows out.
  5. Do not apply viscous fluid that may make fixation of the valve and valve seat.
  6. Connect the product to the pipes securely.

TIP

  1. Before installing the product, remove foreign substances and scale from the piping.
  2. Match the direction of fluid flow with the inlet and outlet of the product respectively.
  3. Install the product vertically with the cap facing upward.
  4. Inner diameters of pipe mount and of exhaust pipe shall be more than those of each inlet and outlet of the product.

Yoshitake AL-31H piping example

Pipe Mount and Exhaust Pipe

  • Pipe mount should have sufficient strength and rigidity against stress which are induced by reaction force.
  • Install the product vertically as close as possible to the can body and the header to prevent pressure loss in the pipe mount.
  • Install exhaust pipe and drip pan elbow so that the product cannot be subject to the stress caused by thermal expansion of equipment.

Maintenance

WARNING

  1. Do not touch the product/pipes with bare hands.
  2. When checking the operation of the product, wear earplugs and stand clear of exhaust pipe end during inspection.
  3. Do not remove the cap.

Daily and Monthly Inspection

Daily: Check for corrosion or crack on the product, leakage from the product under normal working pressure, and leakage from joints between the product and piping.

Monthly: Check that there is no loose piping at the inlet and outlet side of the product, and the cap is fastened securely. Check the operation of the product by raising fluid pressure to the set pressure.

Yoshitake Safety Valves / Relief Valves

AF and AL series safety and relief valves for overpressure protection of steam, water, and air equipment.