Yoshitake KBLV-2SF double-acting pneumatic ball valve. Features a stainless steel full bore body, PTFE seat, and KA type actuator with NAMUR dimensions. Suitable for steam, air, water, and oil.

Yoshitake KBLV-2SF pneumatic ball valve is a full bore type valve featuring a stainless steel body and a double-acting KA type actuator using NAMUR dimensions. It is designed for steam, air, hot and cold water, oil, and other non-hazardous fluids.
| Feature | Specification |
|---|---|
| Model | KBLV-2SF |
| Type | Full bore type |
| Nominal Size | 15 to 100A |
| Application Fluid | Steam, air, hot and cold water, oil, and other non-hazardous fluids |
| Body, Cap Material | Stainless steel |
| Ball Material | Stainless steel |
| Seat Material | PTFE |
| Connection | JIS 10K RF equivalent, ANSI 150lb RF equivalent, EN PN16 equivalent |
| Max. Pressure | 1.4 MPa (JIS), 1.9 MPa (ANSI), 1.6 MPa (EN) |
| Max. Temperature | 167°C |
| Piping Orientation | Horizontal or Vertical (inverted horizontal is not allowed) |
| Flow Direction | No restriction on flow direction |
| Actuator Mapping | 15A/20A: KA12, 25A: KA20, 32A/40A: KA35, 50A: KA50, 65A: KA110, 80A: KA160, 100A: KA255 |
| Feature | Specification |
|---|---|
| Operating Fluid | Air, nitrogen gas |
| Operating Pressure Range | 0.4 MPa to 0.8 MPa |
| Ambient Temperature | -20 to +80°C |
| Operation | Double action |
| Operation Angle | 90° ±5 |
| Body Material | Aluminum alloy |
| Mounting Standard | Valve mounting: ISO5211, Ancillaries: NAMUR |

| Nominal size | L (JIS 10K / ANSI 150lb) | L (EN PN16) | H (JIS 10K) | Weight (JIS 10K) | Weight (ANSI 150lb) | Weight (EN PN16) |
|---|---|---|---|---|---|---|
| 15A | 108 | 130 | 161 | 3.1 | 2.8 | 3.3 |
| 20A | 117 | 150 | 166 | 3.5 | 3.1 | 4.0 |
| 25A | 127 | 160 | 197 | 5.5 | 4.5 | 6.0 |
| 32A | 140 | 180.3 | 218 | 7.1 | 6.0 | 8.1 |
| 40A | 165 | 200 | 241 | 9.0 | 8.4 | 10.0 |
| 50A | 178 | 230 | 261 | 11.8 | 11.7 | 13.4 |
| 65A | 190 | 290 | 300 | 17.8 | 17.7 | 20.1 |
| 80A | 203 | 310 | 333 | 24.7 | 25.0 | 27.6 |
| 100A | 229 | 350 | 369 | 33.5 | 37.7 | 38.0 |
(Dimensions in mm, Weight in kg)
| Actuator Model | 0.4 MPa | 0.45 MPa | 0.5 MPa | 0.55 MPa | 0.6 MPa | 0.7 MPa | 0.8 MPa |
|---|---|---|---|---|---|---|---|
| KA12 | 10 | 11 | 12 | 13 | 14 | 17 | 19 |
| KA20 | 16 | 18 | 20 | 22 | 24 | 28 | 32 |
| KA35 | 29 | 33 | 36 | 40 | 44 | 51 | 58 |
| KA50 | 40 | 45 | 50 | 55 | 60 | 70 | 80 |
| KA110 | 90 | 102 | 113 | 124 | 135 | 158 | 181 |
| KA160 | 132 | 149 | 165 | 182 | 198 | 231 | 264 |
| KA255 | 200 | 226 | 251 | 276 | 301 | 351 | 401 |
(Torque in N·m)
When the operating air is supplied into port A, the pistons move outward discharging air from port B, and the drive pinion rotates counterclockwise (0° to 90°). As a result, the valve opens.

When the operating air is supplied into port B, the pistons move inward discharging air from port A, and the drive pinion rotates clockwise (90° to 0°). As a result, the valve closes.

Installation Orientation
The installation posture can be either horizontal or vertical, but ensure that the actuator is not installed upside down. This may cause malfunction.
Correct:
Wrong:
Piping and Preparation
Safety Precautions
To maintain the product's functionality and performance, perform regular inspections approximately once a year. The actuator is lubricated at the factory and does not require further lubrication.
Inspection Items:
| Faults | Causes | Countermeasures |
|---|---|---|
| External leakage | Loose nut / Loose hex bolt | Tighten the nut / hex bolt. |
| Damaged gasket / gland packing | Replace the product. | |
| Seat leakage | Damaged seat / Damaged ball | Replace the product. |
| Foreign object caught | Remove the foreign object. | |
| Actuator not operating | Operating torque is not enough. | Check if the operating air pressure is appropriate. |
| Valve is locked due to foreign substances. | Clean the valve. | |
| Stops at intermediate position | Valve is locked due to foreign substances. | Clean the valve. |
Yoshitake Isolation Valves / Ball Valves
BLV series and related ball valves for quick isolation of steam, water, air, and oil lines.
Explore similar products in our catalog