BURKERT 20014232 (Type 8746) is an aluminium thermal mass flow controller for oxygen with a 10 Nm3/h flow range, G 1/2 port, 24V DC supply, PROFIBUS DP fieldbus, and integrated Type 2875 proportional valve.

BURKERT 20014232 (Type 8746) is a thermal mass flow controller configured for gaseous oxygen (O2) service across an operating span up to 10 Nm³/h. Constructed with an aluminium fluid block and FKM elastomers, this unit regulates gas flow under a normal operating pressure of 4.5 barg and a nominal flow outlet pressure of 3.0 barg. It incorporates an InlineChipDigital ALU sensor alongside a Type 2875 proportional solenoid control valve featuring a 3.0 mm (1/8") orifice.

| Parameter | Source Specification |
|---|---|
| Manufacturer Type | Type 8746 |
| Article Number (SKU) | 20014232 |
| Operating Mode | Control mode |
| Measurand / State of Aggregation | Flow / Gas |
| Operating Medium | O2 oxygen |
| Calibration Medium | Air with conversion parameter |
| Operating Range | 10 Nm³/h |
| Measuring Span (Turn-down) | 1 : 50 |
| Normal Operating Pressure (Medium 1) | 4.500 barg |
| Output Pressure at Qn (Medium 1) | 3.00000 barg |
| Maximum Operating Pressure | 5 bar |
| Maximum Valve Pressure | 10 bar |
| Pressure Port Connection | G 1/2 threaded port |
| Body Material | Aluminium |
| Seal Material | FKM |
| Mounting Position | Horizontal |
| Special Feature | Version for high difference pressure |
| Sensor Configuration | InlineChipDigital ALU (without extra features) |
| Valve Actuator Reference | Type 2875 proportional control valve |
| Orifice Size | 3.0 mm (1/8") |
| Coil Dimensions | 49 x 49 mm |
| Power of Coil | 16 W |
| Supply Voltage | 24 V DC |
| Power Consumption | 18.5 W (typical: 20 W, UL rating: 34.5 W) |
| Digital Interface / Actual Value Output | PROFIBUS DP |
| Nominal Value Input | Default as actual value output |
| Memory Configuration | With memory card |
The measurement assembly uses the Bürkert InlineChipDigital ALU sensor, which performs direct thermal mass flow detection inside the gas stream. The instrument is calibrated on air with medium-specific conversion parameters loaded for oxygen. With a dynamic turndown range of 1:50, the controller maintains continuous regulation down to 0.2 Nm³/h.
Actuation is driven by an integrated Type 2875 direct-acting proportional valve. The valve incorporates a 49 x 49 mm electromagnetic coil consuming 16 W, operating across a 3.0 mm orifice. This configuration is built specifically as a version for high difference pressure, supporting up to 10 bar maximum valve pressure and a maximum continuous operating pressure of 5 bar.
BURKERT 20014232 operates from a regulated 24 V DC supply. Nominal power consumption is 18.5 W under steady operating conditions, with a typical consumption rating of 20 W and an operational limit of 34.5 W on UL-approved installations. Process data exchange, setpoint provision, and diagnostic reporting are transmitted via PROFIBUS DP.
UL Approval and Configuration Card
Devices bearing UL approval require compliance with UL power ratings up to 34.5 W. The controller includes a dedicated memory card for retaining operating parameters, calibration factors, and device configuration during replacement or maintenance cycles.
The device must be installed in a horizontal orientation to conform to the factory calibration baseline. Prior to connecting fluid lines, verify that all piping is clean and free of particulate matter. G 1/2 threaded ports connect the instrument directly into the oxygen process line.
Start-up Procedure Sequence
When putting the controller into operation or restarting following an interruption, execute tasks strictly in the following sequence:
Electrostatic Discharge (ESD) and Electrical Safety
The device contains electronic assemblies sensitive to electrostatic discharge. Adhere to EN 61340-5-1 handling procedures during installation and service. Never touch exposed electronic components while supply voltage is active. Disconnect and lock out power before performing mechanical or wiring work.
Pressurized Medium and Thermal Hazards
Pressurized media present serious injury risks upon uncontrolled release. De-energize system pressure, vent piping, and confirm zero pressure before loosening fittings. Because fast-switching proportional coils can generate hot exterior surfaces, wear appropriate personal protective equipment and maintain clear separation from flammable materials, especially in oxygen-enriched operational zones.
Explore similar products in our catalog