Skip to content
3/2-Way Direct-ActingPivoted ArmatureATEX / IECEx Ex mbG 1/4Stainless Steel 1.4401FKM Media SeparationIP65

BURKERT 20014863 Type 0330 3/2-Way Ex Solenoid Valve G 1/4

BURKERT 20014863 Type 0330 is an ATEX/IECEx certified direct-acting 3/2-way pivoted armature solenoid valve featuring stainless steel body, FKM seals, G 1/4 ports, and universal circuit function T.

BURKERT 20014863 Type 0330 3/2-Way Ex Solenoid Valve G 1/4

BURKERT 20014863 (Type 0330) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve configured with universal circuit function T. Built with a 1.4401 stainless steel body, FKM seals, and an orifice diameter of 4.0 mm (5/32 inch), the valve controls aggressive, neutral gaseous, and liquid media up to a kinematic viscosity of 37 mm²/s within an operating pressure range of 0.00 to 4.00 bar.

Actuation is powered by an encapsulated Type ACP016 explosion-proof solenoid with an integrated 3000 mm connecting cable. The valve is certified under ATEX and IECEx for Category 2 (Zone 1/21) hazardous industrial environments, with protection ratings II 2 G Ex mb IIC T4 Gb and II 2 D Ex mb IIIC T130°C Db. An isolating diaphragm isolates the fluid chamber completely from the magnetic actuator, eliminating contact between process fluids and internal coil components.

Technical Specifications ​

Specification ParameterValue
Article Number20014863
Model / SeriesType 0330
Valve ConstructionComplete direct-acting valve
Circuit FunctionT (3/2-way universal use, flow direction optional)
Fluidic Ports3 ports (G 1/4 internal thread)
Switching Positions2 positions (on/off)
Nominal Diameter (DN)4.0 mm (5/32")
Flow Factor Kv (Water)0.23 m³/h
Flow Factor QNn (Gas)255 l/min
Operating Pressure Range0.00 to 4.00 bar (gauge)
Main Valve Body MaterialStainless steel 1.4401 (316)
Valve Seat MaterialStainless steel
Seal MaterialFKM (Fluor rubber), 70 Shore A
Coil EncapsulationChemically resistant epoxy, thermal class H
Electrical Supply Voltage230 V AC/DC (50/60 Hz, tolerance ±10%)
Nominal Power RatingInrush: 40 W, Holding: 3 W (electronic power reduction)
Opening Switching Time30 ms (measured at +20 °C, 6 bar outlet pressure)
Closing Switching Time40 ms (measured at +20 °C, 6 bar outlet pressure)
Maximum Switching Frequency20/min (medium temp ≤ +70 °C), 5/min (medium temp ≤ +90 °C)
Permissible Medium Temperature0 °C to +90 °C
Maximum Ambient Temperature+55 °C
Electrical Connection TypeMolded connection cable (3 x 0.5 mm²), length 3000 mm
Cable Connection MaterialBrass
Degree of ProtectionIP65
Explosion Protection MarkingsII 2 G Ex mb IIC T4 Gb, II 2 D Ex mb IIIC T130°C Db
Explosion CertificationsATEX: EPS 16 ATEX 1 111 X; IECEx: IECEx EPS 16.0049X
Installation Length46 mm
Total Unit Weight0.75 kg (metal body explosion-proof variant)
Manual OverrideMechanical override integrated (turn-to-lock)

Media-Separated Design and Materials ​

Type 0330 utilizes pivoted armature technology with complete hermetic media separation. The fluid chamber is sealed off from the magnetic circuit by a vulcanized FKM separating diaphragm. This architecture prevents corrosive, particulate-bearing, or scaling fluids from contacting metallic actuator components.

BURKERT 20014863 Type 0330 internal material components and media-separation cross section

Item No.ElementMaterial
1CoilEpoxy (Class H insulation)
2DiaphragmFKM (Fluor rubber)
3O-ringFKM (Fluor rubber)
4SeatStainless steel 1.4401
5Valve bodyStainless steel 1.4401

FKM seal construction provides chemical compatibility with oxidizing acids, salt solutions, oils with additives, waste gases, and oxygen over a medium temperature range from 0 °C to +90 °C.

Fluidic Port Allocation and Universal Function T ​

Circuit function T provides universal 3/2-way flow functionality with optional flow direction. In the de-energized position, port 1 is normally closed (NC), while port 3 is connected to port 2 (NO).

BURKERT 20014863 Type 0330 3-way explosion-proof port connection layout

Circuit FunctionConnection 1Connection 2Connection 3
Function T (Universal)1 (NC / P)2 (IN / OUT / A)3 (NO / R)

Depending on process pipe configuration, function T can be piped as a normally closed valve, normally open valve, diverting/distribution valve, or mixing valve.

Pressure Limits Across Alternate Circuit Functions ​

The internal compression springs installed in Type 0330 valves are engineered around specific circuit configurations. If article 20014863 is piped to operate in other circuit functions, maximum permissible operating pressures adjust according to the manufacturer specifications below:

Factory ConfigurationConfigured Function AConfigured Function BConfigured Function CConfigured Function DConfigured Function EConfigured Function F
Function T (DN 4 Metal Body)3.0 bar3.0 bar3.0 bar3.0 bar3.0 bar3.0 bar

Dimensions and Installation Guidelines ​

BURKERT 20014863 Type 0330 explosion-proof cable variant dimensional drawing

The valve body measures 46 mm across fluidic connection ports. Port threads are G 1/4 with a 9.0 mm thread depth. On metal bodies, the minimum internal thread length at the middle fluid connection is 7.5 mm.

  • Bottom mounting: Two tapped M4 holes spaced in a 38 x 24 mm hole pattern on the underside of the housing (maximum screw-in depth 8 mm).
  • Mounting orientation: Flexible installation position, preferably with the solenoid actuator upright.
  • Piping attachment: Hold the body firmly using an open-ended spanner; do not use the coil housing as a lever arm. Seal pipe joints using PTFE tape.

Dirt Trap Requirement

For safe operation and protection against seat fouling, install a dirt trap with mesh size ≤ 500 µm upstream of the valve inlet.

Manual Override Mechanism ​

Article 20014863 includes a mechanical manual override on the actuator side for commissioning, dry running, and function tests without electrical power.

BURKERT 20014863 Type 0330 manual override actuation and locking mechanism

  • To actuate manually: Press and hold the override element.
  • To lock in position: Press and turn clockwise.

Manual Override Locking

When the manual override is locked in position, the valve cannot be actuated electrically. An optional circlip accessory (article no. 013372) is available to prevent accidental manual engagement.

Electrical Connection and Explosion Safety ​

The ACP016 coil features an integrated, non-detachable 3000 mm cable outlet. An internal bridge rectifier permits connection to AC or DC voltage sources without polarity restrictions. The coil incorporates electronic power reduction (Kick-and-Drop) which draws 40 W during initial inrush and automatically switches to 3 W continuous holding power, minimizing thermal load.

Wire ColourElectrical Pin Assignment
Green-YellowProtective earth conductor (PE)
BlackPhase / positive pole (+)
BlackNeutral conductor / negative pole (−)

Electrical and Pressure Hazard

Disconnect electrical power and ensure lines are depressurized and drained before beginning maintenance, disassembly, or installation work. Always connect the green-yellow protective conductor and verify electrical continuity between the coil and valve body.

Electrostatic Discharge Protection

To prevent explosion risks in Category 2 (Zone 1/21) atmospheres, wipe the epoxy coil housing only with a damp or antistatic cloth. Do not operate the device in processes generating strong electrostatic charges, close to electrostatic coating systems, or during pneumatic dust conveyance.

Troubleshooting and Maintenance ​

Prior to placing the valve into service or when diagnosing operating faults, verify that the unit is installed according to flow orientation, lines are clean and vented, nominal voltage matches the type label, and mounting screws are tightened.

Fault ObservedPotential CauseCorrective Action
Valve does not switchCoil circuit shorted or interruptedCheck power line continuity and supply voltage
Valve does not switchOperating pressure exceeds 4 bar limitRegulate process supply pressure within 0–4 bar
Valve does not switchManual override locked in manual stateUnlock manual override by turning counter-clockwise
Valve does not closeForeign particulate or dirt trapped in valve seatClean lines and inspect upstream dirt trap (≤ 500 µm)
Valve does not closeManual override mechanically engagedRotate override back to resting electrical position

Repairs involving internal electrical or pressure components must be executed by the manufacturer to preserve explosion-proof compliance and factory performance specifications.