Skip to content
Type 8652Article 200325258 Valve SlotsIndustrial EthernetAirLINE Quick Stainless Steel16 Digital InputscULus ListedIP20 / NEMA 4X

BURKERT 20032525 Type 8652 AirLINE 8-Slot Valve Island with Stainless Steel AirLINE Quick and Industrial Ethernet

BURKERT 20032525 (Type 8652) is an 8-slot AirLINE valve island with 6 dual 3/2-way CF-C valves, 2 blind plates, stainless steel AirLINE Quick plate, 16 digital inputs, and Industrial Ethernet via dual RJ45.

BURKERT 20032525 Type 8652 AirLINE 8-Slot Valve Island with Stainless Steel AirLINE Quick and Industrial Ethernet

BURKERT 20032525 (Type 8652 AirLINE) is an 8-bank pneumatic valve island engineered for process automation environments. Factory configured under build code 20032525, this unit features an 8-valve slot pneumatic manifold mounted directly to a stainless steel AirLINE Quick adapter plate. It is populated across positions 1 through 6 with dual 3/2-way normally closed solenoid pilot valves (circuit function C), while positions 7 and 8 are sealed with blind plates for future expansion. Field connectivity is provided via dual RJ45 Industrial Ethernet ports supporting multi-protocol industrial networks, complemented by 16 integrated digital inputs across two electronic input modules.

BURKERT 20032525 Type 8652 AirLINE valve island

Equipped with an integrated liquid crystal display, Type 8652 visualizes diagnostic statuses and process alerts directly at the valve terminal in clear text and standardized icons. Diagnostic information is simultaneously transmitted to the higher-level PLC over the active fieldbus, accelerating commissioning and fault isolation. The system operates from -1.00 bar to 10.00 bar main air pressure with an internal pilot air feed operating between 3.00 bar and 10.00 bar, providing standard nominal flow rates of up to 310 l/min air per station.

Specific Configuration of Article 20032525 ​

Article 20032525 defines a factory-assembled pneumatic and electronic configuration with specific pneumatic porting, valve slices, and protocol profiles.

Specification ParameterValue for Article 20032525
Product TypeType 8652 AirLINE
Identification NameValve island 8652 8-bank ALQ VA
Article Number (SKU)20032525
Number of Valve Slots8 PCE
Valve Slot 12x 3/2-way CF-C (Normally Closed)
Valve Slot 22x 3/2-way CF-C (Normally Closed)
Valve Slot 32x 3/2-way CF-C (Normally Closed)
Valve Slot 42x 3/2-way CF-C (Normally Closed)
Valve Slot 52x 3/2-way CF-C (Normally Closed)
Valve Slot 62x 3/2-way CF-C (Normally Closed)
Valve Slot 7Blind plate
Valve Slot 8Blind plate
Total Digital Inputs16 (Module 1 with DI: Yes, Module 2 with DI: Yes)
AirLINE Quick Plate MaterialStainless steel 1.4301
Supply Connection (Port 1)D 3/8" push-in, Stainless steel 1.4401
Working Ports (Ports 2 and 4)D 1/4" push-in, Stainless steel 1.4401
Auxiliary Pilot Air SupplyInternal (3 to 10 bar)
Additional Air Supply FeedsWithout left, middle, or right auxiliary feed modules
Integrated Check ValvesPort 3 (R): No; Port 5 (S): No
Pneumatic HotSwap in Port 1 (P)No
Communication InterfaceIndustrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic)
Communication Hardware Ports2 x RJ45 ports (X1 and X2)
Degree of ProtectionIP20 (bare unit), NEMA 4X / IP65 inside closed stainless steel cabinet
Safety CertificationcULus Listed (UL 61010-1, CAN/CSA-C22.2 No. 61010-1)

AirLINE Quick Adapter Interface ​

AirLINE Quick enables direct mounting of the valve terminal into the wall or floor of a control cabinet, eliminating individual internal bulkhead bulk and tubing runs.

BURKERT 20032525 Type 8652 AirLINE Quick adapter plate

Connecting pneumatic hoses directly on the exterior bottom surface reduces cabinet volume requirements and shortens assembly time. For article 20032525, the adapter plate is fabricated from stainless steel 1.4301 with push-in fluid fittings machined from stainless steel 1.4401.

Technical FeatureAirLINE Quick Specification
Adapter Plate MaterialStainless steel 1.4301 (or anodised aluminium in alternate builds)
Push-in Pneumatic Fitting MaterialStainless steel 1.4401 (or nickel-plated brass)
Supported Station Capacities8, 16, 24, 32, 40, and 48 valve functions
Supply and Exhaust Port DimensionsPush-in D 10 mm, 3/8" (D 3/8" on 20032525)
Working Port DimensionsPush-in D 6 mm, 1/4" (D 1/4" on 20032525)
Mounting OrientationsControl cabinet floor or control cabinet wall

General Technical Specifications ​

Type 8652 conforms to standard pneumatic and electrical specifications under DIN EN and ISO industrial standards.

Attribute CategoryTechnical Specification
Housing MaterialPolyamide (PA)
Seal MaterialsNBR and PUR
Station Width11 mm per valve slice
Maximum Number of SlotsUp to 24 slots (48 controllable valve functions)
Manual Override TypesLatching and spring-return (lockable options available)
Operating Pressure RangeVacuum to 10 bar (-1.00 bar to 10.00 bar)
External Pilot Air Range3 to 10 bar (when using external pilot feed)
Nominal Air Flow Rate QNn310 l/min (at +20 °C, 6 bar inlet, 1 bar delta P; reduced ~3% if HotSwap fitted)
Operating Duty CycleContinuous operation (100% ED)
Operating Voltage24 V DC (±10% tolerance)
Residual Ripple1 Vss
Power Consumption per Valve0.7 W nominal (drops to 0.175 W after internal power reduction)
Current Draw per Valve29 mA nominal (drops to 10 mA after power reduction)
Electrical Protection ClassClass III in accordance with DIN EN 61140, VDE 0140
Operating FluidOil-free or lubricated dry compressed air, neutral gases
Compressed Air QualityISO 8573-1:2010, Class 7.4.4 (5 µm pre-filter recommended)
Storage Temperature-20 °C to +60 °C
Operating Ambient Temperature-10 °C to +55 °C

Filtration Recommendation

To maintain pilot spool response times and extend the operating life of the 11 mm valves, ensure dry compressed air satisfies ISO 8573-1:2010 Class 7.4.4 with a pre-filtration rating of 5 µm or finer.

Circuit Functions and Pilot Valves ​

Article 20032525 contains six active stations using circuit function C (CF C), which pairs two independent 3/2-way servo-assisted normally closed solenoid valves on each 11 mm station body. Unused stations 7 and 8 are covered by dummy plates.

Function CodeValve DescriptionStandard Flow Path
CF C (2x 3/2-way)Two 3/2-way solenoid valves, servo-controlled, normally closed when de-energizedPressure at (1) blocked; working ports (2) and (4) vented to exhaust (3)/(5)
CF C (Single 3/2-way)3/2-way solenoid valve, servo-controlled, normally closedDe-energized closed position with manual override
CF D (2x 3/2-way)Two 3/2-way solenoid valves, servo-controlled, normally open when de-energizedPressure at (1) continuously routed to working ports when de-energized
CF H (5/2-way)5/2-way solenoid valve, servo-controlledSingle solenoid impulse: pressure on (1) charges either port (2) or (4)
CF Z (5/2-way)5/2-way bi-stable solenoid valve with 2 coilsDouble-solenoid bistable latching operation
CF L (5/3-way)5/3-way solenoid valve, middle position closedAll ports blocked in central position
CF M (5/3-way)5/3-way solenoid valve, middle position pressurizedPorts (2) and (4) connected to supply in central position
CF N (5/3-way)5/3-way solenoid valve, middle position exhaustedPorts (2) and (4) connected to exhaust in central position
Blind PlateNon-pneumatic blanking plateHermetically seals base pneumatic manifold slot

Approvals, Conformity, and Hazardous Area Specifications ​

Article 20032525 carries standard cULus listing under UL 61010-1 and CAN/CSA-C22.2 No. 61010-1 for general electrical measurement and control equipment. Installed inside an appropriate control cabinet with its stainless steel AirLINE Quick plate, it satisfies NEMA Type 4X.

Optional Type 8652 hardware executions comply with explosive atmosphere directives (PU17 and PX68 suffix options):

  • ATEX Certificate: BVS 20 ATEX E 031 U, marking II 3G Ex ec IIC Gc and II 3D Ex tc IIIC Dc
  • IECEx Certificate: IECEx BVS 20.0024 U, marking Ex ec IIC Gc and Ex tc IIIC Dc
  • North American Hazardous Locations (cURus HazLoc): Class I, Zone 2, AEx ec IIC Gc; Class II, Zone 22, AEx tc IIIC Dc; Class I, Division 2, Groups A, B, C, D; Class II/III, Division 2, Groups F, G
  • China Compulsory Certification (CCC): Ex compliance under GB/T 3836 series standards audited by SITIIAS

Hazardous Location Disconnection Rules

When deploying explosive-atmosphere-rated configurations of Type 8652, do not connect or disconnect electrical spring-loaded terminals (24 V power, SIA, EVS, digital inputs) while energized. Hot swapping of valves is strictly prohibited unless the atmosphere is proven to be non-hazardous.

Dimensions and Installation Guidelines ​

Article 20032525 belongs to the 8-valve-slot mechanical footprint. Mounting can be executed directly onto the cabinet wall/floor through the AirLINE Quick interface or onto DIN rails compliant with EN 50022 (35 x 7.5 mm or 35 x 15 mm).

BURKERT 20032525 Type 8652 dimensional drawing 4 8 12 fold

Footprint VariantDimension A (mm)Dimension B (mm)Mounting Holes CGrid Factor mFasteners n
4-fold (4 slots)66—4 x M531
8-fold (8 slots)351118 x M572
12-fold (12 slots)7715410 x M5113

For 16-slot, 20-slot, and 24-slot variants, an intermediate supply block is available, requiring different hole layouts:

  • 16-fold with intermediate feed: A=112 mm, B=224 mm, C=10 x M5, D=114.3 mm
  • 20-fold with intermediate feed: A=134 mm, B=268 mm, C=10 x M5, D=158.3 mm
  • 24-fold with intermediate feed: A=156 mm, B=312 mm, C=10 x M5, D=158.3 mm

When positioning Type 8652 inside an enclosure, maintain clearance to the cabinet front door and back panel to allow valve slice insertion and screw access.

Electrical and Fieldbus Connections ​

The internal assembly separates electronic communication bus power from pneumatic valve coil excitation, allowing independent safety shutdown of valve actuation circuits.

BURKERT 20032525 Type 8652 internal product assembly structure

5-Pin Spring-Loaded Terminal: Communication and Displays ​

Accepts conductor cross-sections up to 1.5 mm².

Pin PositionTerminal Wire ColourAssigned Signal
1Red+24 V DC (Logic and display)
2WhiteCAN_H (büS interface)
3GreenShielding
4BlueCAN_L (büS interface)
5Black0 V DC (GND)

2-Pin Spring-Loaded Terminal: Pneumatic Valve Power ​

Independent electrical feed for solenoid coils. Accepts conductor cross-sections up to 1.5 mm².

Terminal PositionTerminal Wire ColourAssigned Function
1RedAUX +24 V DC (Valve power supply)
2Black0 V DC (GND)

Industrial Ethernet Interface: Dual RJ45 (Ports X1 and X2) ​

Article 20032525 features dual RJ45 Ethernet connectors (X1 and X2) supporting linear and ring network topologies.

BURKERT 20032525 Type 8652 Industrial Ethernet RJ45 port interface

Contact PinIndustrial Ethernet Signal (X1 / X2)
1TX+ (Transmit Data +)
2TX- (Transmit Data -)
3RX+ (Receive Data +)
4Not connected (N.C.)
5Not connected (N.C.)
6RX- (Receive Data -)
7Not connected (N.C.)
8Not connected (N.C.)

Fieldbus Redundancy and Multi-protocol Operation

The integrated Ethernet controller supports PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic. PROFINET S2 system redundancy is also supported when higher network availability is required.

Digital Input Electronic Modules ​

Article 20032525 includes two 8DI electronic modules, providing 16 digital input channels for sensor feedback such as valve limit switches.

BURKERT 20032525 Type 8652 electronic module digital inputs

Inputs are energized at 24 V DC with current limiting set to a maximum of 30 mA per input. Conductor cross-section accommodates rigid or flexible leads from 0.14 mm² to 1.5 mm² with cable runs up to 30 meters.

Parameter8DI Module Specification
Diagnostic FunctionsWire-break detection on 2-wire sensors; short-circuit detection on 3-wire sensors
Sensor Compatibility2-wire sensors (10–30 V), 3-wire sensors, mechanical dry-contact switches
Switching ThresholdsV_OFF = 0 to 5 V; V_ON = 10 to 30 V
Channel Input Current at V_ONMax. 5.7 mA per channel (typical at 24 V DC)
Input Impedance> 4 kΩ
Galvanic IsolationNo (channels share common reference potential)
Maximum Cable Length< 30 m
Diagnostic Capability3-Wire Sensors2-Wire SensorsMechanical Limit Switches
Sensor Actuated StateYesYesYes
Sensor Unactuated StateYesYesYes
Short Circuit DetectionYesNoNo
Wire Break DetectionNoYesNo

Network Topology and EDIP Integration ​

Type 8652 functions as an Industrial Ethernet master valve terminal capable of linking subordinate büS slave islands via its CAN-based local communication link.

BURKERT 20032525 Type 8652 network topology configuration example

System configuration, parameter mapping, diagnostic interrogation, and firmware management are managed using the Bürkert Communicator software (Type 8920) within the EDIP (Efficient Device Integration Platform) framework. Physical connection to a configuration PC requires a USB-CAN adapter kit.

SIA Safety Shut-off Options

For safety-related circuit interruption, Burkert provides SIA variants of Type 6534 pilot valves and module-based emergency shutdown links. SIA valves use external potential-free contacts (relays or mechanical switches) rated for 0.5 A at 24 V DC on coded 2-pin screw terminals. Modular shutdown units handle up to 1.5 A at 24 V DC over 12-pin spring-loaded headers.

Component and Replacement Ordering Reference ​

Type 8652 components and maintenance items utilize exact Burkert order codes.

Replacement Pilot Valves (Type 6534 for Type 8652) ​

Valve FunctionWidthNominal QNnPressure RangeResponse TimeOrder Code (with Screws)
CF C (2x 3/2-way NC)11 mm270 l/minVac. to 10 bar15 ms open / 15 ms close301374 (REF_296031)
CF D (2x 3/2-way NO)11 mm310 l/minVac. to 10 bar15 ms open / 15 ms close301375 (REF_296032)
CF H (5/2-way mono)11 mm290 l/minVac. to 10 bar20 ms open / 25 ms close301376 (REF_296033)
CF Z (5/2-way bistable)11 mm290 l/minVac. to 10 bar20 ms open / 25 ms close301377 (REF_296034)
CF L (5/3-way mid closed)11 mm275 l/minVac. to 10 bar15 ms open / 15 ms close301380 (REF_296036)
Blind Plate (Dummy Valve)11 mm———335779 (REF_327614)

Connection and Electronic Modules ​

Component DescriptionOrder Code
Electronic Display Module with DI Contacts (8DI)384872
Electronic Display Module without DI Contacts384873
Left Pneumatic Supply Module with Pressure Sensor (D 1/4" and D 3/8")384868
Left Pneumatic Supply Module without Pressure Sensor (D 1/4" and D 3/8")384864
5-Pin Spring-Loaded Terminal Block (Logic & Display Power)920180
2-Pin Spring-Loaded Terminal Block (Pneumatic Valve AUX 24 V)920442
Fieldbus Gateway Type ME43 (Industrial Ethernet)301799
USB büS Interface Set 1 (Type 8923 with stick, cables, power supply)772426
AirLINE Quick M5 x 10 A2 DIN 6912 Cabinet Fastening Screws (Set of 10)308661
AirLINE Quick Height Adapter for 8-valve plate754960
AirLINE Quick Retaining Plate for 8-valve plate60005566
AirLINE Quick Blind Plate for 8-valve plate754965