Skip to content
PROFIBUS DPV18 Valve Slots16 Valve FunctionsAirLINE Quick AluminiumPneumatic HotSwapATEX / IECEx Zone 2/22IP20 / IP65 Cabinet

BURKERT 20032688 Type 8652 AirLINE 8-Bank Pneumatic Valve Island with PROFIBUS DPV1

BURKERT 20032688 Type 8652 AirLINE is an 8-slot pneumatic valve island with PROFIBUS DPV1, AirLINE Quick aluminium adapter plate, 16 CF-C valve functions, integrated check valves, and pneumatic HotSwap.

BURKERT 20032688 Type 8652 AirLINE 8-Bank Pneumatic Valve Island with PROFIBUS DPV1

BURKERT 20032688 (Type 8652 AirLINE) is an 8-slot modular pneumatic valve island configured for process automation in control cabinets. Fitted with an AirLINE Quick anodised aluminium base plate, this unit provides 8 valve slots equipped with dual 3/2-way normally closed solenoid valves (Circuit Function C), yielding 16 independently controlled pneumatic valve functions. Process connections feature push-in D10 mm brass supply ports (port 1) and push-in D6 mm brass working ports (ports 2 and 4). Integrated check valves in exhaust ducts 3 (R) and 5 (S) prevent unintentional actuator movement caused by backpressure spikes, while integrated pneumatic HotSwap functionality at port 1 (P) enables individual valve replacement during ongoing plant operation without pressure interruption.

Communication is handled by an integrated PROFIBUS DPV1 interface module via a 9-pin Sub-D connector. Diagnostic parameters and valve switching states are visualised directly on the built-in LC display in clear text and standardized symbols, and transmitted cyclically to the higher-level PLC. The valve island is rated for continuous operation (100% duty cycle) across an operating pressure range of vacuum to 10 bar (-1.00 bar to 10.00 bar), with an auxiliary pilot air supply requirement of 3 bar to 10 bar.

Technical Specifications ​

ParameterSpecification
Type8652 AirLINE
Article number (Ident number)20032688
Number of valve slots8 slots (11 mm station width each)
Installed valve functions16 (8 slots × dual 3/2-way CF-C)
Body materialPolyamide (PA)
Seal materialsNBR and PUR
AirLINE Quick adapter plateAnodised aluminium
Supply connection (port 1)Push-in fitting D10 mm, nickel-plated brass
Working ports (ports 2 and 4)Push-in fitting D6 mm, nickel-plated brass
Auxiliary pilot airInternal supply
Intermediate feed modules0 (none required for 8-slot configuration)
Operating pressure rangeVacuum to 10 bar (-1.00 bar to 10.00 bar)
Auxiliary pilot pressure range3 bar to 10 bar
Nominal flow rate QNn (air)310 l/min (measured at +20 °C, 6 bar inlet, 1 bar Δp; approx. 3% flow reduction with HotSwap)
Operating mediumCompressed dry air (lubricated or oil-free), neutral gases
Compressed air qualityISO 8573-1:2010, Class 7.4.4 (5 µm filtration recommended)
Operating voltage24 V DC (±10%, residual ripple 1 Vss)
Power per valve coil0.7 W nominal (0.175 W after electronic power reduction)
Current per valve coil29 mA nominal (10 mA after electronic power reduction)
Digital inputs0 (without DI electronic module)
Degree of protectionIP20 (bare) / IP65 (installed with AirLINE Quick in closed control cabinet)
Ambient operating temperature-10 °C to +55 °C
Fluid / medium temperature-10 °C to +55 °C
Storage temperature-20 °C to +60 °C
Duty cycleContinuous operation (100% ED)
Protection classIII according to DIN EN 61140, VDE 0140

AirLINE Quick Adapter Plate ​

BURKERT 20032688 AirLINE Quick anodised aluminium adapter plate

AirLINE Quick allows direct mechanical and pneumatic installation onto the control cabinet floor or wall, eliminating bulkhead feedthrough fittings. All pneumatic connections for supply air, exhaust air, and working lines pass through the cabinet base plate.

  • Floor and wall cut-out mounting eliminates individual hose pass-throughs
  • Anodised aluminium adapter plate construction
  • Nickel-plated brass push-in fittings: D10 mm for supply/exhaust, D6 mm for working lines 2 and 4
  • Ingress protection reaches IP65 when mounted in a suitable closed control cabinet

Valve Configuration and Circuit Functions ​

Article 20032688 is configured with 8 valve slots, each populated with a Type 6534 dual 3/2-way servo-controlled solenoid valve in Circuit Function C (normally closed). Each valve module operates with latching manual override (spring return) and 11 mm width per station.

PositionCircuit FunctionDescriptionQNn (Air)Switching Time OpeningSwitching Time Closing
Slot 1 to 82 × 3/2-way CF-CDual 3/2-way solenoid valve, servo-controlled, normally closed, with manual override270 l/min15 ms15 ms

Integrated exhaust check valves in ports 3 and 5 prevent back-venting into unpressurised actuator chambers when adjacent valves discharge. The integrated pneumatic HotSwap function at port 1 incorporates a shut-off mechanism that permits individual valve removal under working pressure while the remaining 7 valve stations continue running.

Dimensions and Mounting ​

BURKERT 20032688 Type 8652 8-fold valve island dimensional drawing

Dimensions for 4-, 8-, and 12-slot configurations according to Type 8652 technical documentation (all dimensions in mm):

ConfigurationA (mm)B (mm)Cmn
4-slot66—4 × M531
8-slot (20032688)351118 × M572
12-slot7715410 × M5113

The assembly can alternatively be mounted on standard DIN rails (EN 50022, 35 × 7.5 mm or 35 × 15 mm). When installing inside a control cabinet, clearance to the front edge and rear wall must be maintained.

BURKERT 20032688 control cabinet installation clearance for hot swap

Control Cabinet Clearance for Hot Swap

To enable unimpeded replacement of valve modules under HotSwap operation, observe the minimum clearance to the front edge of the control cabinet specified in the Type 8652 operating manual. Ensure adequate spacing between the cabinet rear wall and the mounting plate for cable routing and air line radius.

Electrical and Fieldbus Connections ​

The valve island utilizes separate power supplies for the electronic communication/display circuits and the pneumatic valve coils to permit emergency shutdown of valve outputs without disrupting fieldbus communication.

Electronics and Display Power Supply (5-Pin Spring Terminal) ​

BURKERT 20032688 5-pin spring-loaded terminal for communication and display power

PinColourAssignment
1Red24 V DC
2WhiteCAN_H (büS connection)
3GreenShielding
4BlueCAN_L (büS connection)
5BlackGND (0 V DC)

Permissible conductor cross-section is ≤ 1.5 mm².

Pneumatic Valve Power Supply (2-Pin Spring Terminal) ​

BURKERT 20032688 2-pin spring-loaded terminal for pneumatic valve power supply

ClipColourAssignment
1RedAUX 24 V DC
2BlackGND (0 V DC)

PROFIBUS DPV1 Fieldbus Interface (Sub-D 9-Pin) ​

BURKERT 20032688 PROFIBUS DPV1 Sub-D 9-pin connector pin assignment

PinSignalDescription
1ShieldingCable shield / ground
2M2424 V ground return (optional)
3RxD/TxD-PReceive / Transmit data positive (B-line)
4CNTR-PControl signal P (repeater direction control, optional)
5DGNDData ground (0 V)
6+5 V+5 V DC termination power supply
7+24 V24 V DC power supply (optional)
8RxD/TxD-NReceive / Transmit data negative (A-line)
9CNTR-NControl signal N (optional)

Diagnostic Display and Monitoring

The built-in LC display shows diagnostic notifications in plain text and symbols. Operating status, error codes, and channel states can be evaluated at the cabinet floor without external configuration tools, while cyclical diagnostics are reported via PROFIBUS DPV1 to the process controller.

Explosion Protection and Hazardous Area Guidelines ​

Article 20032688 complies with explosion protection standards for equipment category 3 in Zone 2 (gas) and Zone 22 (dust):

Standard / AuthorityMarkingCertificate Number
ATEXII 3G Ex ec IIC Gc
II 3D Ex tc IIIC Dc
BVS 20 ATEX E 031 U
IECExEx ec IIC Gc
Ex tc IIIC Dc
IECEx BVS 20.0024 U
CCCCertified for hazardous areas in ChinaGB/T 3836 series
cURus HazLocClass I, Zone 2, AEx ec IIC Gc / Ex ec IIC Gc U
Class II, Zone 22, AEx tc IIIC Dc / Ex tc IIIC Dc U
Class I, Division 2, Groups A, B, C, D
Class II, III, Division 2, Groups F, G
E-file certification

Hazardous Area Operating Restrictions

  • In potentially explosive atmospheres, the 24 V DC power supply, SIA connections, and digital input terminals must only be connected or disconnected when completely de-energised.
  • The pneumatic HotSwap function must not be used while a potentially explosive atmosphere is present. Valve replacement under pressure is permitted only when test equipment verifies that no hazardous atmosphere exists.
  • For type of protection "ec", install inside an enclosure meeting EN/IEC 60079-0 and EN/IEC 60079-7 with minimum IP54 ingress protection.
  • For type of protection "tc", install inside an enclosure meeting EN/IEC 60079-0 and EN/IEC 60079-31 with minimum IP6X ingress protection.
  • Transient protection must limit voltage surges to a maximum of 140% of the nominal peak supply voltage.

Replacement Valves and Accessories ​

Individual valve slices on the 8652 island are replaceable as spare parts. For article 20032688, replacement valves correspond to Type 6534:

Circuit FunctionOrificeQNn (Air)Pressure RangeVoltageReplacement Valve Part No.Spare Part Set Part No.
2 × 3/2-way CF-C (installed)4 mm270 l/minVac. to 10 bar24 V DC301374296031
2 × 3/2-way CF-D4 mm310 l/minVac. to 10 bar24 V DC301375296032
5/2-way CF-H4 mm290 l/minVac. to 10 bar24 V DC301376296033
5/2-way impulse CF-Z4 mm290 l/minVac. to 10 bar24 V DC301377296034
5/3-way CF-L (closed mid)4 mm275 l/minVac. to 10 bar24 V DC301380296036
5/3-way CF-M (pressurised mid)4 mm300 l/minVac. to 10 bar24 V DC301379296035
5/3-way CF-N (exhausted mid)4 mm300 l/minVac. to 10 bar24 V DC301381296039
Dummy valve plate————335779327614

AirLINE Quick Fastening and Height Adapters ​

DescriptionQuantityArticle Number
Screw set M5 × 10 A2 DIN 6912 (base fastening)10 pcs308661
Height adapter for 8-fold base (without intermediate feed)1 pc754960
Retaining plate for 8-fold base (cabinet exterior)1 pc60005566
Blind plate for 8-fold base1 pc754965
5-pin spring-loaded terminal (electronics/display)1 pc920180
2-pin spring-loaded terminal (valve supply AUX 24 V)1 pc920442