Burkert Type 8652 AirLINE valve island optimized for process automation. Features LC display diagnostics, pneumatic HotSwap, Industrial Ethernet, and ATEX/IECEx Zone 2 approvals.

BURKERT 20043955 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller. This, therefore, enables a fast overview of the plant status.

The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is, of course, also possible. Moreover, key pneumatic functions ensure increased process reliability. For instance, check valves in the exhaust air ducts make sure there is no unplanned actuation due to pressure peaks.

BURKERT 20043955 Burkert 8652 AirLINE valve island overview

General Technical Data

Product propertiesDescription
Body MaterialPA (polyamide)
Seal MaterialNBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Pneumatic intermediate supplyOptional for the variants with 16, 20 and 24 valve slots
Pressure rangeVacuum to 10 bar
External supply air3 to 10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10%)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Nominal current of each valve29 mA (10 mA after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C to +55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet
Product propertiesDescription
AirLINE Quick Adapter PlateStainless steel 1.4301 / Anodised aluminium
Pneumatic connectionStainless steel 1.4401 / Nickel-plated brass
Valve functions per station8, 16, 24, 32, 40 and 48
Pneumatic Supply / ExhaustPush-in D 10 mm, 3/8"
Pneumatic working portsPush-in D 6 mm, 1/4"
Installation positionControl cabinet wall / Control cabinet floor

BURKERT 20043955 Burkert 8652 AirLINE Quick adapter plate

Circuit Functions

Circuit FunctionDescription
C (CF C)3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
C (CF C)2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
D (CF D)2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open
H (CF H)5/2-way solenoid valve, Servo-controlled, with manual override, Pressure applied via port (1)
L (CF L)5/3-way solenoid valve, With manual override, In middle position all ports locked
M (CF M)5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated
N (CF N)5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted
Z (CF Z)5/2-way solenoid valve, Impulse variant with 2 coils and manual override

SIA Variant (for safety-related shut-off)

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants.

Approvals and Conformities

  • Explosion protection: As a category 3 device suitable for zone 2/22. ATEX: II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc. IECEx: Ex ec IIC Gc / Ex tc IIIC Dc.
  • North America (USA/Canada): UL Listed (UL 61010-1, CAN/CSA-C22.2 No. 61010-1). Optional UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Division 2).
  • China Compulsory Certification (CCC): Products with Ex approval are suitable for import and use for hazardous applications in China.

Dimensions

Variant 4-, 8- and 12-fold

BURKERT 20043955 Burkert 8652 dimensions for 4, 8, and 12-fold variants

VariantABCmn
4-fold66-4 x M531
8-fold351118 x M572
12-fold7715410 x M5113

Variant 16-, 20- and 24-fold

BURKERT 20043955 Burkert 8652 dimensions for 16, 20, and 24-fold variants

VariantABCDmm'n
16-fold with intermediate supply11222410 x M5114.3774
20-fold with intermediate supply13426810 x M5158.31175
24-fold with intermediate supply15631210 x M5158.311116
16-fold without intermediate supply9919810 x M5-15-4
20-fold without intermediate supply12124210 x M5-19-5
24-fold without intermediate supply14328610 x M5-23-6

Product Connections

Power supply for communication and displays

Connect 5-pin spring-loaded terminal according to the pin assignment (Possible cable cross-section: ≤ 1.5 mm²).

PinColourAssignment
1Red24 V DC
2WhiteCAN_H (büS connection)
3GreenSHIELDING
4BlueCAN_L (büS connection)
5BlackGND

Power supply for pneumatic valves

The interface plate has a 2-pin spring-loaded terminal to which the pneumatic valves’ power supply is connected.

PinColourAssignment
1RedAUX 24 V
2BlackGND

Industrial Ethernet Interface

PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic or PROFINET S2 – Interface X1 and X2 RJ45.

PinAssignment
1TX+
2TX-
3RX+
6RX-
4, 5, 7, 8N.C.

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20043955 Burkert 8652 installation clearance in control cabinet

Example Configuration

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20043955 Burkert 8652 network configuration example with Industrial Ethernet

Safety Instructions for Hazardous Locations

  • Danger from voltage: Before working on the device or system, disconnect the power supply. Secure against reactivation.
  • Explosion hazard due to electrostatic charge: In the event of a sudden discharge from electrostatically charged devices or individuals, there is a risk of explosion in the potentially explosive area. Only clean the device surface by wiping it gently with a damp or antistatic cloth.
  • Hot Swap: The use of the Hot Swap function is prohibited in a present explosive atmosphere. If it can be proven and ensured with suitable test equipment that no explosive atmosphere is present for a certain period of time, it is permissible to remove/insert valves using Hot Swap during this time.