BURKERT 20051376 (Type 8640) is a REV3 4-bank pneumatic valve block featuring 16.5 mm station width, 4x 3/2-way normally closed valves, G 3/8 supply, D8 push-in ports, and ATEX/IECEx Ex ia IIC T6 certification.

BURKERT 20051376 (Type 8640) is a 4-bank pneumatic valve block engineered on the Revision 3 (REV3) modular architecture. It is factory-configured with four servo-controlled 3/2-way solenoid valves operating under circuit function C (normally closed). Built with a 16.5 mm station width per valve position, this unit integrates common pneumatic supply ports G 3/8 and downward-facing D8 push-in working connections directly on the pneumatic base module. The block operates without an internal fieldbus communication module, utilizing individual single wiring connections.
Designed for demanding industrial and hazardous environments, article 20051376 delivers an air flow rate of 700 l/min per station under standard reference conditions. The valve island block provides an operating pressure range from 2.00 bar to 8.00 bar, operates at 24 V DC with an energy-efficient 1 W nominal coil power rating, and carries hazardous area certifications under ATEX and IECEx for II 2 G Ex ia IIC T6 classification.
| Parameter | Specification |
|---|---|
| Article Number | 20051376 |
| Valve Island System | Type 8640 |
| Generation / Revision | Revision 3 (REV3) |
| Configuration | 4-bank valve block (04-bank) |
| Width per Station | 16.5 mm |
| Valve Function | 4x 3/2-way valve function C (servo-controlled, normally closed) |
| Manual Override | Standard manual override integrated on each valve |
| Supply Port 1 (P), Exhaust Ports 3 (R), 5 (S) | G 3/8 |
| Working Port 2 (A), 4 (B) | D8 push-in coupling (bottom pneumatic module orientation) |
| Operating Pressure Range | 2.00 bar to 8.00 bar |
| Auxiliary Pilot Air Requirement | > 2 bar (when external supply air is configured) |
| Flow Rate QNn Air | 700 l/min (measured at +20 °C, 6 bar inlet pressure, 1 bar differential) |
| Medium Temperature Range | 0 °C to 50 °C |
| Ambient Temperature Range | 0 °C to 55 °C |
| Operating Medium | Oil-free or lubricated compressed dry air, neutral gases (5 µm filtering) |
| Compressed Air Quality Class | ISO 8573-1: 2010, Class 7.4.4 |
| Nominal Operating Voltage | 24 V DC (±10% voltage tolerance, residual ripple 1 Vss) |
| Nominal Power per Valve | 1 W |
| Operating Duty Cycle | 100% continuous operation (ED) |
| Electrical Connection Type | Single wiring (without internal bus communication, 0 digital inputs) |
| Installation Mounting | Standard DIN rail EN 50022 (35 x 7.5 mm or 35 x 15 mm) |
| Valve Body Material | Polyamide (PA) / Aluminium |
| Sealing Material | NBR |
| Ingress Protection Rating | IP20 (protection class III according to VDE 0580) |
| Explosion Protection Approvals | Z003 ATEX, Z004 IECEx |
| Explosion Protection Marking | II 2 G Ex ia IIC T6, Ex ia IIC T6 |

The Type 8640 REV3 platform introduces optimized mechanical and pneumatic features over earlier REV1 and REV2 revisions. For 16 mm station blocks, the REV3 generation features a wavy channel arrangement for the working connections, blue release rings on the push-in tube connectors, and a standardized valve flange interface.
Revision 3 Efficiency
Revision 3 pneumatic modules limit the pressure drop across integrated P-shut-off elements to a maximum flow reduction of 20%, whereas earlier revisions experienced up to 50% flow reduction.

Article 20051376 is equipped with four 3/2-way servo-controlled valves configured in Circuit Function C. In the de-energized rest position, pressure supply port 1 (P) is closed, while working port 2 (A) exhausts to port 3 (R). Upon electrical energization, the pilot rocker mechanism shifts, opening supply port 1 to working port 2 and sealing exhaust port 3.
Each valve station includes a manual override that allows manual commissioning and testing without electrical excitation. To activate the manual override, press and rotate the mechanism 90° clockwise until it locks. It does not automatically reset and must be manually restored to zero position before resuming normal electrical control.
| Operational Stage | Response Time |
|---|---|
| Opening Time (Switching On) | 20 ms |
| Closing Time (Switching Off) | 12 ms to 17 ms |
| Nominal Valve Power | 1 W (24 V DC) |
| Standard Coil Connection Interface | Tag connector DIN EN 175301-803 Form C |

The valve block is pre-configured for DIN rail mounting according to standard rail EN 50022 (35 x 7.5 mm or 35 x 15 mm). Installation is carried out by engaging the upper hook groove of the modular block onto the top edge of the DIN rail, pressing the lower clamping pieces into place, and securing them with the clamping screws.
Installation position is arbitrary, with the preferred orientation having the solenoid actuators positioned upright. Single valves mounted onto base modules are fastened using two M3 x 30 mm screws tightened to the recommended mounting torque of 0.6 ±0.1 Nm.

The modular pneumatic section is constructed from high-quality polyamide (PA) elements joined by integrated snap hooks and sealed by elastomeric O-rings:
Push-In Hose Connection Guidelines (ISO 14743)
To prevent connection leakage and ensure full holding capability:
Operating Pressure Limits
The differential pressure between supply port 1 and exhaust port 3 must be at least 2 bar. If the system operating temperature drops below 0 °C, operation must be restricted strictly to dried compressed air to prevent internal freezing.
Article 20051376 satisfies European and international safety requirements for equipment deployed in potentially explosive gas atmospheres. The unit holds certification approvals:
When installed in an industrial control cabinet, the system provides ingress protection IP20. In fully closed enclosures meeting appropriate housing standards, protection levels up to IP65 can be maintained.

Maintenance and modular expansion of the Type 8640 REV3 16 mm system utilize standardized Bürkert components:
| Position | Description | Specification / Content | Article No. |
|---|---|---|---|
| 1 | Replacement 3/2-way valve (CF C) | Type 6526, 2.0-8.0 bar, 24 V DC, 1 W | 156840 / 158947 |
| 2 | Cover plate | Cover plate for Type 6526 / 6527 valve slot | 653765 |
| - | Electrical connection cover | Cover plate for electrical connection 6526/6527 | 657519 |
| 3 | Valve seal kit | FM17 spare valve seals (pack of 12) | 20016307 |
| 4 | Module seal kit | MP17 spare module seals (pack of 4) | 20016310 |
| 5 | Left supply unit | Type 8640, 16 mm, G 3/8 connection | 20042793 |
| 5 | Right supply unit | Type 8640, 16 mm, G 3/8 connection | 20042796 |
| 6 | Base module 4-fold | Base unit Type 8640, 16 mm, 4-fold, D8, FM17 | 20042790 |
| 6 | Base module 4-fold with check valve | Base unit Type 8640, 16 mm, 4-fold, D8, FM17, RSV | 20042792 |
Explore similar products in our catalog