BURKERT 20059157 (Type 0330) 3/2-way direct-acting solenoid valve. Features stainless steel body, FKM seal, G1/8 internal thread, 24V DC, and 0-12 bar pressure range.

BURKERT 20059157 (Type 0330) is a direct-acting, media-separated pivoted armature valve. As a 3/2-way variant (Circuit Function F), it operates as a distribution valve where normally inlet port 1 (P/IN) is connected with outlet port 2 (B/NO), and outlet port 4 (A/NC) is closed. The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a diaphragm, the valve is especially suitable for critical media such as aggressive acids and alkalis. The 20059157 model features a stainless steel body, FKM seals, and operates on 24V DC.
| Property | Value |
|---|---|
| Orifice | DN 2.0 mm |
| Body Material | Stainless steel (1.4401) |
| Seal Material | FKM (Fluor rubber) |
| Weight | Metal body: 0.45 kg |
| Thermal insulation class | Epoxy coil class H |
| Duty cycle | 100% continuous operation |
| Voltage | 24 V DC |
| Voltage tolerance | ±10% |
| Degree of protection | IP65 with cable plug |
| Installation position | As required, preferably with actuator upright |
Circuit function F (CF F): 3/2-way distribution valve (solenoid valve), Direct-acting.


| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Diaphragm | FKM |
| 3 | O-ring | FKM |
| 4 | Seat | Stainless steel (1.4401) |
| 5 | Valve body | Stainless steel (1.4401) |
Note
Dimensions in mm. For metal bodies, the minimum thread length at the middle connection is 7.5 mm.

| D1 | L1 | D2 | L2 |
|---|---|---|---|
| G 1/8 | 9 | - | - |
| G 1/4 | 9 | NPT 1/4 | 7.5 |
Pressure range and flow rate (Standard variant, Metal body)
| Circuit function | DN | Kv value water (DC) [m³/h] | Pressure range Standard [bar] | Pressure range Vacuum [bar] |
|---|---|---|---|---|
| A / B / C / D / F | 2 | 0.08 | 0...16 | -0.98...10 |
Limitation
The maximum medium pressure is 12 bar for seal material FKM. The specific model 20059157 is rated for a maximum of 12 bar.
Pin assignment standard variant
The pin assignment depends on the circuit function. For Circuit Function F:

DANGER!
Risk of injury from high pressure in the system/device
Risk of injury from electric shock
WARNING!
Risk of injury due to improper installation