Skip to content
5/2-WayG 1/4DN 8.0 mm24V DC1300 l/minATEX / IECEx Cat 3GDIP65

BURKERT 20061319 Type 6519 5/2-Way Pneumatic Solenoid Valve, G 1/4, 24V DC

BURKERT 20061319 (Type 6519) is a servo-assisted 5/2-way pneumatic valve with DN 8.0 mm, 1300 l/min flow rate, G 1/4 ports, 24V DC operation, and ATEX/IECEx Cat 3GD certification.

BURKERT 20061319 Type 6519 5/2-Way Pneumatic Solenoid Valve, G 1/4, 24V DC

BURKERT 20061319 (Type 6519) is a servo-assisted 5/2-way pneumatic solenoid valve engineered for controlling double-acting pneumatic actuators. Operating at 24 V DC with a 2 W continuous hold rating, it features an 8.0 mm nominal orifice (DN 8) delivering a nominal flow rate of 1300 l/min. The valve body is manufactured from glass-fibre reinforced polyamide with integrated brass threaded bushings for internal G 1/4 fluidic connections. The sealing arrangement comprises wear-resistant polyurethane (PUR) and nitrile rubber (NBR) elastomer seats. Operating within a pressure range of 2.0 to 10.0 bar, the unit is certified under ATEX and IECEx Category 3GD (II 3 G Ex ec IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc) for hazardous industrial atmospheres.

BURKERT 20061319 Type 6519 standard 5/2-way pneumatic solenoid valve

Circuit Function and Switching Operation ​

BURKERT 20061319 operates in circuit function H (servo-assisted 5/2-way, normally open). Supply pressure applied via port 1 connects internally to working port 2, while working port 4 vents through exhaust port 5 and exhaust port 3 remains closed. When energized, the internal pilot valve repositions the main valve spool, routing pressure from port 1 to working port 4 while working port 2 discharges through exhaust port 3.

BURKERT 20061319 Type 6519 circuit function H schematic with manual override

The unit is equipped with a mechanical manual override on the pilot body. In de-energized conditions, the manual override is actuated by pushing downward and rotating 90° clockwise until it latches at the stop position. Resetting the override requires rotating it 90° counterclockwise back to its resting position.

Switching dynamics under standard test conditions (+20 °C, 6 bar inlet pressure):

  • Opening response time: 20 ms (measured from 0 to 10% pressure build-up)
  • Closing response time: 40 ms (measured from 100 to 90% pressure reduction)

INFO

Monostable circuit functions C, D, and H within the Type 6519 family can achieve a safety integrity level of SIL 2 in accordance with IEC 61508, contingent upon the architecture of the overarching safety system.

Technical Specifications ​

ParameterSpecification
Valve Type6519
Order Identifier (Article No.)20061319
Circuit FunctionH (5/2-way servo-assisted, normally open)
Width32 mm
Nominal Diameter (DN)8.0 mm (main valve), 1.2 mm (pilot valve)
Nominal Flow Rate (QNn air)1300 l/min (+20 °C, 6 bar inlet, 1 bar Δp)
Operating Pressure Range2.0 to 10.0 bar (differential pressure ≥ 2 bar)
Operating Voltage24 V DC (tolerance ±10%)
Nominal Power Consumption2 W (Hold, warm coil)
Duty Cycle100% ED continuous operation
Coil Thermal Insulation ClassPolyamide coil Class B, Epoxy coil Class H
Main Valve Body MaterialPolyamide (PA, glass-fibre reinforced)
Threaded Bushing MaterialBrass
Seal MaterialPolyurethane (PUR) and Nitrile rubber (NBR)
Fluidic Ports (1, 2, 3, 4, 5)G 1/4 internal thread (ports 1, 3, 5 flange-mountable)
Auxiliary Pilot PortM5 internal thread
Weight478 g (single 5/2-way with 32 mm coil)
Degree of ProtectionIP65 with properly assembled cable plug
Explosion ProtectionII 3 G Ex ec IIC T4 Gc, II 3 D Ex tc IIIC T135°C Dc

Pneumatic and Media Operating Conditions ​

BURKERT 20061319 is intended for use with neutral gaseous media, including dry lubricated or oil-free compressed air. The operating media must meet the purity standards of ISO 8573-1:2010, Class 7.2.4 or Class 7.4.4.

Operating Temperature and Dew Point Limits

  • Permitted medium temperature: -10 °C to +55 °C.
  • Permitted ambient temperature: -25 °C to +55 °C.
  • To prevent ice formation from expanding compressed air, the pressure dew point of the operating air must be at least 10 K below the actual medium temperature.

Port Designation and Layout ​

Every fluidic connection is molded directly on the valve body:

  • Port 1: Main pressure inlet (P)
  • Port 2: Working port (B), opposite supply side
  • Port 4: Working port (A), opposite supply side
  • Port 3: Exhaust port (R)
  • Port 5: Exhaust port (S)
  • Port 12 / 14: Auxiliary pilot air connection (M5 thread)

Dimensions and Installation Guidelines ​

BURKERT 20061319 can be mounted in any orientation, though installation with the solenoid coil facing upright is recommended. The valve body is secured directly using M4 fastening screws into wall structures or mounted onto modular manifold rails.

BURKERT 20061319 Type 6519 dimensional drawing with Form A plug

Tightening Torques ​

Connection / FastenerRecommended TorqueMaximum Permissible Torque
G 1/4 Fluidic Ports4 to 7 Nm20 Nm
M5 Auxiliary Pilot Port1.0 to 1.2 Nm3 Nm
M4 Body Fastening Screws2 Nm5 Nm
Solenoid Retaining Nut (AC10)—5 Nm
Pilot Control to Main Body Screws—1.5 Nm
Cable Plug Retaining Screw (Form A)—1.0 Nm

Rotating the Solenoid Coil

The AC10 solenoid coil can be repositioned around its axis in 4 × 90° increments (limited to 2 × 180° when mounted in manifold blocks). To reposition, loosen the top retaining nut with an open-end wrench, orient the coil to the desired angle, and re-tighten the retaining nut to a maximum torque of 5 Nm. Do not use the solenoid body as a lever.

Modular Block Assembly with Type MP07 ​

For centralized pneumatic distribution, multiple Type 6519 valves can be combined on Type MP07 pneumatic manifold modules mounted on standard 35 mm DIN rails (DIN EN 50022 or 50023) or direct surface mounts. Up to 12 valves can be grouped per manifold assembly.

BURKERT 20061319 modular block assembly

Manifold Block Components ​

ItemDescriptionOrdering Number
1Left Connection Module (G 1/2)635324
2Base Module, 3-fold universal635343
3Intermediate Module (through-supply) / Right Connection Module637505
4Base Module, 2-fold universal635319
5Right Connection Module (G 1/2)635331
6Common Exhaust Port 3 (R)Integrated in modules
7Common Supply Port 1 (P)Integrated in modules
8Common Exhaust Port 5 (S)Integrated in modules
9Cover plate for unused 5/2-way valve positions635335

Electrical Connection and Explosion Protection ​

BURKERT 20061319 features plug contacts conforming to DIN EN 175301-803 Form A. The mating cable plug is not included in the standard delivery scope and must be ordered separately.

Compatible Cable Connectors ​

  • Type 2518 (Form A): Standard industrial connector for 0 to 250 V AC/DC (Article 314802 without wiring; Article 314812 with 12-24 V LED; Article 314820 with LED and varistor).
  • Type 2513 (Form A): Heavy-duty cable plug meeting ATEX Category 3GD requirements when assembled to BURKERT solenoid valves (Article 260890 with 300 mm cable; Article 260891 with 3000 mm cable; Article 260892 with 5000 mm cable).

Electrical Safety and Earthing Requirements

  • Disconnect power supply before opening or servicing the valve.
  • Always connect the protective conductor. The continuity resistance between the solenoid earth contact and the valve body must not exceed 0.1 Ω at a test current of 1 A (12 V test voltage).
  • When operating in hazardous locations classified under Category 3GD, ensure the installation conforms strictly to the permissible ambient temperature (-25 °C to +55 °C) and voltage ratings on the type label.

Maintenance and Troubleshooting Guidelines ​

When operated within specified media purity, pressure, and ambient ranges, the Type 6519 solenoid valve requires no routine maintenance.

Troubleshooting Checklist ​

  • Valve fails to actuate: Inspect power supply against the type label voltage (24 V DC); verify coil continuity; check operating pressure is between 2.0 and 10.0 bar; verify differential pressure is at least 2 bar.
  • Valve fails to switch off / close: Check for particulate contamination within the main valve body or pilot valve seat; inspect hose lines upstream and ensure pre-filtration (≤ 500 µm dirt trap) is intact.
  • Solenoid overheating: Ensure pilot control is fully fastened to the valve body (max 1.5 Nm) prior to electrical energization. Never energize the solenoid coil detached from the valve core guide tube.