Burkert Type 2104 pneumatically operated diaphragm T-valve. Features a stainless steel body, PPS or stainless actuator, and hygienic design for decentralised automation.

Burkert Type 2104 is an externally controlled diaphragm T-valve consisting of a pneumatically operated piston actuator, a diaphragm, and a T-valve body. The proven and robust actuator with a stainless steel housing ensures reliable use in hygienic or aggressive ambient conditions. The flow-efficient valve bodies with minimal dead space enable high flow rates and a wide range of possible uses. The actuator features a compact, autoclavable design with gap-free seals, offering IP65/67 and NEMA Type 4X protection. The integration of automation units Type ELEMENT is possible in all configuration levels, and an explosion-proof ATEX/IECEx device variant is available.

| Product properties | Description |
|---|---|
| Block body (VH/VI) | Stainless steel block material 1.4435 according to DIN EN 10088 and 316L according to ASTM A479 / A479M / ASME BPE |
| Diaphragm | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
| Actuator | DN 08...65, PPS; DN 65...100, stainless steel 1.4308 |
| Actuator casing | DN 08...65, stainless steel 1.4561 (316Ti); DN 65...100, stainless steel 1.4308 |
| Standard surface quality | Internally electrically polished: Ra ≤ 0.38 μm (ASME BPE SF4 / DIN HE4); Internally mechanically polished: Ra ≤ 0.5 μm (ASME BPE SF1) |
| Maximum pilot pressure | 10 bar (7 bar for actuator size 130, 225) |
| Pilot air port | Push-in connector for outer diameter, ∅ 6 mm or 1/4" (standard), thread G 1/8" |
| Operating medium | Neutral gases and liquids, highly purified, sterile, aggressive or abrasive mediums |
| Ambient temperature | -10 °C...+ 60 °C (autoclavable) |

ATEX/IECEx Safety
For use in potentially explosive atmospheres, observe the information on the device and the additional instructions with Ex labelling. The device must be properly grounded to prevent electrostatic charging hazards.
| Diaphragm material | Medium temperature [°C] | Comments |
|---|---|---|
| EPDM (AD) | -10...+143 | Steam sterilisation max. +150°C for 60 min |
| FKM (FF) | 0...+130 | No steam, dry heat max +150°C for 60 min |
| PTFE (EA) | -10...+130 | Steam sterilisation max. +140°C for 60 min |
| Advanced PTFE (EU) | -5...+143 | Steam sterilisation max. +150°C for 60 min |
| GYLON® (ER) | -5...+130 | Steam sterilisation max. +140°C for 60 min |

Installation Position
The valve can be installed in any position, preferably with the actuator facing up. For leakage detection, one of the relief bores in the diaphragm bonnet must be at the lowest position.
When installing the actuator on the valve body, tighten the body screws in three stages (approx. 1/3, then 2/3 and then full tightening torque) crosswise.
| Diaphragm size | EPDM, FKM [Nm] | PTFE, advanced PTFE, GYLON® [Nm] |
|---|---|---|
| 8 | 2 | 2.5 |
| 15 | 3.5 | 4 |
| 20 | 4 | 4.5 |
| 25 | 5 | 6 |
| 40 | 8 | 10 |
| 50 | 12 | 15 |
| 65 | 20 | 30 |
| 80 | 30 | 40 |
| 100 | 40 | 50 |