Skip to content
Direct-acting2/2-wayIP65DN 1.2

BURKERT 20074754 Type 7011 Direct-Acting 2/2-Way Plunger Valve, Brass, M5

Bürkert 20074754 Type 7011 direct-acting 2/2-way plunger valve. Features a brass body, M5 internal thread, 1.2mm orifice, FKM seal, and 24V DC operation for 0-16 bar pressure ranges.

BURKERT 20074754 Type 7011 Direct-Acting 2/2-Way Plunger Valve, Brass, M5

Bürkert 20074754 Type 7011 is a direct-acting and compact small plunger valve up to DN 2.4. To increase pressure resistance and leak-tightness, the stopper and the core guide tube are welded together. This specific model features a brass body, FKM seals, an M5 internal thread connection, and operates on 24 V DC. It is designed for circuit function A (normally closed) and is suitable for neutral gaseous and liquid media.

The valve utilizes a slipped-over coil system and allows for simple and fast mounting. In combination with a suitable plug conforming to DIN EN 175301-803 shape B, the valve satisfies the IP65 degree of protection.

General Technical Data

FeatureSpecification
OrificeDN 1.2
Body materialBrass
Seal materialFKM (Fluor rubber)
Operating voltage24 V DC
Nominal pressure0 to 16 bar
Medium temperature-10 °C to +100 °C
Ambient temperature-10 °C to +75 °C
ViscosityMax. 21 mm²/s
Degree of protectionIP65 (with suitable connector)

Circuit Function

Circuit function A (CF A): 2/2-way solenoid valve, direct-acting, normally closed.

Material Specifications

Bürkert 20074754 material specifications for circuit function A

No.ElementMaterial
1NutDIN 176 Surface finish thick film passivated KOSA0101
2StopperStainless steel 1.4113/434
3Core guide tubeStainless steel 1.4303 ST/305L
4Shading ringCopper (optional silver)
5CoreStainless steel 1.4113/434
6SpringStainless steel 1.4310/301
7SealFKM
8Valve bodyBrass
9O-ringFKM
11CoilEpoxy

Dimensions

Threaded Variant

Bürkert 20074754 threaded variant dimensions

Port connectionA [mm]B [mm]C [mm]D [mm]
M55201010

Safety Instructions

Risk of injury from high pressure in the system or device Before working on the system or device, switch off the pressure and ventilate and empty the lines.

Risk of injury from electric shock Before working on the system or device, switch off the power supply and secure against reactivation. Observe the applicable accident prevention and safety regulations for electrical devices.