Skip to content
16-Slot BaseAirLINE Quick AluminiumIndustrial Ethernet8x 5/2-Way MonostableVacuum to 10 barIP20 / IP65 in Cabinet

BURKERT 20075348 Type 8652 AirLINE 16-Slot Pneumatic Valve Island with AirLINE Quick Adapter

BURKERT 20075348 Type 8652 AirLINE is a 16-slot pneumatic valve island with 8 pre-installed 5/2-way valves, aluminium AirLINE Quick plate, Industrial Ethernet gateway, and LC diagnostic display.

BURKERT 20075348 Type 8652 AirLINE 16-Slot Pneumatic Valve Island with AirLINE Quick Adapter

BURKERT 20075348 (Type 8652 AirLINE) is a modular electropneumatic valve island engineered for process automation environments. Configured with a 16-slot base, the unit features eight factory-fitted Type 6534 5/2-way monostable solenoid valves (circuit function H) on valve positions 1 through 8, accompanied by eight blanking plates across positions 9 through 16 to accommodate future capacity expansion. Process line interfacing is handled via an integrated AirLINE Quick anodised aluminium base plate, allowing direct mechanical coupling to control cabinet floors or walls while routing pneumatic connections externally.

Pneumatic ports use brass push-in fittings, with D10 mm connectors assigned to supply air port 1 and D6 mm connectors assigned to working ports 2 and 4. Auxiliary pilot air is routed internally and operates within an inlet pressure span of 3 to 10 bar. Nominal line operating pressure spans from -1.00 bar (vacuum) to 10.00 bar. Communication and system diagnostics are powered by an ME43 fieldbus gateway supporting multi-protocol Industrial Ethernet, including PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic via dual RJ45 connectors (X1 and X2).

Specific Configuration for Article 20075348 ​

Article 20075348 delivers a factory-assembled pneumatic manifold configured with 16 valve slots, an intermediate feed module, and an AirLINE Quick adapter.

Attribute / PositionSpecification
Valve Slot Count16 PCE
Valve Positions 1 to 85/2-way monostable, circuit function H (CF-H)
Valve Positions 9 to 16Blind plate (dummy valve)
Supply Connection (1)Push-in connector D10 mm (brass)
Working Ports (2 and 4)Push-in connector D6 mm (brass)
Base Mounting PlateAirLINE Quick anodised aluminium adapter plate
Auxiliary Pilot AirInternal (3 to 10 bar)
Intermediate Supply1 PCE intermediate feed module installed
Additional Supply (Left)Push-in connector D6 and D10
Additional Supply (Right)Without
Additional Supply (Middle)Without
Digital Input Modules0 installed (El. modules 1 to 4 with DI: No)
Exhaust Check Valves (3/5)Not installed
Pneumatic HotSwap in 1 (P)Not installed
Communication HardwareFieldbus module ME43 with dual RJ45 ports
Supported ProtocolIndustrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic)
Ingress ProtectionIP20 (bare) / IP65 inside closed control cabinet via AirLINE Quick

Technical Data ​

Type 8652 functions as a central pneumatic control hub. Each individual pilot station features an 11 mm slice width, constructed with polyamide (PA) bodies and NBR/PUR elastomeric seals.

Technical ParameterValue
Operating Pressure RangeVac to 10 bar (-1.00 bar to 10.00 bar)
Auxiliary Pilot Air Pressure3 bar to 10 bar
Nominal Flow Rate QNn (Air)290 l/min (CF-H 5/2-way); 310 l/min (CF-D 2x3/2-way) at +20 °C, 6 bar inlet, 1 bar Δp
Operating Voltage24 V DC (±10%, residual ripple 1 Vss)
Power Consumption per Valve0.7 W nominal (0.175 W after internal power reduction)
Current Draw per Valve29 mA nominal (10 mA after power reduction)
Operating ModeContinuous operation (100% duty cycle)
Switching Time (ISO 12238)CF-H: Opening 20 ms, Closing 25 ms
Protection ClassIII according to DIN EN 61140, VDE 0140
Operating MediumOil-free or lubricated dry compressed air, neutral gases (ISO 8573-1:2010 Class 7.4.4, 5 µm filter)
Ambient Temperature-10 °C to +55 °C
Medium Temperature-10 °C to +55 °C
Storage Temperature-20 °C to +60 °C

Auxiliary Pilot Air

Internal auxiliary pilot air feeds the 6534 pilot stage directly from the main supply duct when system pressure is maintained at or above 3 bar. For operating pressures falling below 3 bar or vacuum service down to -1 bar, separate external pilot air must be supplied at 3 to 10 bar.

AirLINE Quick Adapter Interface ​

AirLINE Quick allows direct mechanical mounting to the cabinet floor or side wall. The adapter plate isolates the pneumatic connection ports outside the enclosure, eliminating cabinet-interior hose routing and reducing enclosure volume.

BURKERT 20075348 AirLINE Quick adapter plate and pneumatic port arrangement

FeatureMaterial / Dimension
Adapter Plate MaterialAnodised aluminium (optional 1.4301 stainless steel)
Pneumatic Port MaterialNickel-plated brass (optional 1.4401 stainless steel)
Supply / Exhaust PortsPush-in connector D10 mm (3/8")
Working PortsPush-in connector D6 mm (1/4")
Installation PositionControl cabinet floor or control cabinet wall

Dimensional Data for 16-Slot Configuration ​

Article 20075348 incorporates 16 valve slots along with an intermediate supply module.

BURKERT 20075348 Type 8652 dimensional drawing for 16-slot valve island with intermediate supply

VariantA (mm)B (mm)C (Screws)D (mm)mm'n
16-slot with intermediate supply11222410 x M5114.3774
16-slot without intermediate supply9919810 x M5—15—4

All dimensions are stated in millimetres. The intermediate supply block alters the center pitch distance, requiring mounting coordinates D = 114.3 mm and symmetry indices m = 7 and m' = 7.

Electrical Connections and Bus Interfaces ​

Type 8652 segregates logic and valve driving power supplies into dedicated physical terminal blocks on the interface board.

BURKERT 20075348 Type 8652 product assembly and 24 V interface plate

Power Supply for Communication and Displays ​

Power supply for electronics, display, and CANopen/büS communication connects via a 5-pin spring-loaded terminal block (Article no. 920180) supporting conductor cross-sections up to 1.5 mm².

Pin / TerminalWire ColourSignal Assignment
1Red+24 V DC
2WhiteCAN_H (büS connection)
3GreenShielding
4BlueCAN_L (büS connection)
5BlackGND (0 V DC)

Valve Power Supply (AUX 24 V) ​

Pneumatic valve coils receive power from a separate 2-pin spring-loaded terminal block (Article no. 920442) located on the 24 V interface plate, allowing independent safety disconnection of the pneumatic power stage.

TerminalWire ColourSignal Assignment
1RedAUX +24 V DC
2BlackGND (0 V DC)

Industrial Ethernet Interface (Dual RJ45) ​

The ME43 module provides two RJ45 ports (X1 and X2) supporting linear and ring Ethernet topologies across PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic.

BURKERT 20075348 Industrial Ethernet dual RJ45 interface port pin assignment

RJ45 PinSignal Assignment
Pin 1TX+
Pin 2TX-
Pin 3RX+
Pin 4Not connected (N.C.)
Pin 5Not connected (N.C.)
Pin 6RX-
Pin 7Not connected (N.C.)
Pin 8Not connected (N.C.)

Cabinet Installation and Mechanical Clearances ​

When mounting inside an enclosure, maintain precise dimensional allowances to ensure proper latching and clearance for maintenance tools.

BURKERT 20075348 control cabinet floor mounting and front clearance dimensions

Front Clearance for Maintenance

Ensure a minimum clearance between the front edge of the valve island and the cabinet door frame or adjacent obstacles. Restricted clearance prevents the release mechanism of the 6534 pilot valves from pivoting during replacement.

Network Topologies and Diagnostic Features ​

Type 8652 incorporates an integrated liquid crystal (LC) display that shows status messages, valve switching states, and system faults in clear text and graphic symbols. Diagnostic messages are simultaneously packaged into cyclic bus telegrams for controller-side evaluation.

BURKERT 20075348 Industrial Ethernet master and büS slave network architecture

In a distributed plant architecture, an Industrial Ethernet-equipped Type 8652 functions as the fieldbus master island, interconnecting sub-stations equipped with büS interfaces via standard M12 cables. This avoids individual Ethernet drops for smaller secondary valve groups.

Commissioning with Bürkert Communicator

Parameter setting, cyclic I/O mapping, and diagnostic monitoring can be executed using Bürkert Communicator software (Type 8920) linked through a USB-to-büS programming adapter kit (Article no. 772426). The software enables graphical process value monitoring and complete device configuration backup.

Circuit Functions and Replacement Valves ​

Article 20075348 is equipped with 6534-type solenoid valves in circuit function H alongside blanking plates. Additional 6534 variants can be retrofitted onto the manifold positions.

Function CodeDescriptionOrifice (mm)QNn Air (l/min)Pressure Range (bar)Opening (ms)Closing (ms)Article Number
CF C3/2-way NC, servo-controlled4270Vac to 10 (pilot 3–10)151520102334
CF C (2x)2x 3/2-way NC, servo-controlled4270Vac to 10 (pilot 3–10)1515301374
CF D (2x)2x 3/2-way NO, servo-controlled4310Vac to 10 (pilot 3–10)1515301375
CF H5/2-way monostable (installed)4290Vac to 10 (pilot 3–10)2025301376
CF Z5/2-way bistable (impulse, 2 coils)4290Vac to 10 (pilot 3–10)2025301377
CF L5/3-way, middle position closed4275Vac to 10 (pilot 3–10)1515301380
CF M5/3-way, middle position pressurized4300Vac to 10 (pilot 3–10)2020301379
CF N5/3-way, middle position exhausted4300Vac to 10 (pilot 3–10)2020301381
Blind PlateEmpty slot dummy cover (installed)—————335779
Optional SIA Safety-Related Shut-off and 8DI Electronic Modules

Type 8652 supports optional safety shut-off (SIA) architectures. When equipped with SIA-variant 6534 valves or the modular SIA shutdown strip (Article no. 384872), valve coil circuits can be disconnected via external dry contacts (0.5 A / 24 V DC rating per valve, or 1.5 A / 24 V DC for module-level shut-off). Optional 8DI modules accept 2-wire and 3-wire PNP proximity switches, providing wire-break and short-circuit monitoring.

Hazardous Area Conditions and Explosion Protection ​

When deployed under ATEX, IECEx, or North American hazardous location classifications, Type 8652 requires compliance with supplementary operating requirements:

  • ATEX / IECEx Certification: Certificate BVS 20 ATEX E 031 U and IECEx BVS 20.0024 U; marked II 3G Ex ec IIC Gc and II 3D Ex tc IIIC Dc.
  • North American Approval (cURus): Class I, Zone 2, AEx ec IIC Gc / Ex ec IIC Gc U; Class II, Zone 22, AEx tc IIIC Dc / Ex tc IIIC Dc U; Class I, Division 2, Groups A, B, C, D; Class II/III, Division 2, Groups F, G.
  • Enclosure Protection: The valve terminal must be installed in a certified enclosure providing at least IP54 protection for gas (Zone 2 / 3G) or IP6X for dust (Zone 22 / 3D) compliant with EN/IEC 60079-0, EN/IEC 60079-7, or EN/IEC 60079-31.
  • Transient Suppression: System power supplies must feature transient overvoltage protection set not to exceed 140% of the nominal peak supply voltage.
  • Electrical Disconnection Limits: In potentially explosive atmospheres, live plugging or unplugging of the 24 V supply, SIA circuits, EVS contacts, or digital input plugs is prohibited. All circuits must be de-energised before disconnecting.
  • Hot-Swap Restrictions: Pneumatic hot-swap replacement of valves while pressurised is prohibited in explosive atmospheres unless the zone is verified and certified to be free of flammable gases by atmospheric testing.
  • Electrostatic Charge Control: Surfaces must only be cleaned using a damp cloth to prevent electrostatic discharge.

Accessories and Spare Parts ​

DescriptionSpecificationArticle Number
Replacement Valve CF-HType 6534 5/2-way monostable 24 V DC301376
Replacement Blind PlateFor unpopulated valve stations335779
Fieldbus Gateway ME43Industrial Ethernet multi-protocol module301799
5-Pin Terminal BlockPower supply for electronics and display920180
2-Pin Terminal BlockValve power supply AUX 24 V920442
Fastening Screw Set10x M5x10 A2 DIN 6912 for AirLINE Quick base308661
USB büS Interface Set 1Type 8923 with stick, power supply, and cables772426
Communicator SoftwareType 8920 EDIP PC configuration softwareType 8920