Skip to content
Direct-actingIP65FKM Seal24V DC

BURKERT 20082383 Type 7012 3/2-way Solenoid Valve

BURKERT 20082383 (Type 7012) direct-acting 3/2-way plunger solenoid valve. Normally closed, 1.6mm orifice, 0-6 bar, stainless steel body, M5 thread, 24V DC, FKM seal.

BURKERT 20082383 Type 7012 3/2-way Solenoid Valve

The BURKERT 20082383 (Type 7012) is a direct-acting, compact 3/2-way plunger solenoid valve. To increase pressure resistance and leak-tightness, the stopper and the core guide tube are welded together. This specific model features a stainless steel body, FKM (Fluor rubber) seal, M5 internal thread, and operates at 24V DC. It is designed for blocking, dosing, filling, and ventilating neutral gaseous and liquid media such as compressed air, water, hydraulic oil, and technical vacuum.

General Technical Data

FeatureSpecification
Orifice1.6 mm
Circuit FunctionC (Normally closed)
Body MaterialStainless steel 1.4305/303
Seal MaterialFKM (Fluor rubber)
Port ConnectionM5 Internal thread
Operating Voltage24 V DC
Pressure Range0 - 6 bar
Medium Temperature-10 °C to +100 °C
Ambient TemperatureMax. +75 °C
Degree of ProtectionIP65 with cable plug
Duty Cycle100% continuous operation

Circuit Functions

Circuit function C (CF C): 3/2-way solenoid valve, direct-acting, normally closed. Inlet port 1 (P/NC), outlet port 2 (A/OUT) connected with exhaust port 3 (R/NO).

Materials

BURKERT 20082383 Type 7012 material specifications and components

No.ElementMaterial
1NutDIN 176 Surface finish thick film passivated KOSA0101
2StopperStainless steel 1.4113/434
3Shading ringCopper (silver optional)
4CoreStainless steel 1.4113/434
5Core guide tubeStainless steel 1.4303/305L
6SpringStainless steel 1.4310/301
7O-ringFKM
8SealFKM
9Valve bodyStainless steel 1.4305/303
10FlangeNickel-plated surface (stainless steel variant)
11CoilEpoxy

Dimensions

Threaded Variant (M5)

BURKERT 20082383 Type 7012 threaded variant dimensions

Port connectionA [mm]B [mm]C [mm]D [mm]
M55201414

Safety Instructions

Risk of injury due to high pressure

Before working on the system or device, switch off the pressure and ventilate and empty the lines.

Risk of injury from electric shock

Before working on the system or device, switch off the power supply and secure against reactivation. Observe any applicable accident prevention and safety regulations for electrical devices.

Risk of burns or fire

Keep the device away from highly flammable substances and media and do not touch with bare hands, as the solenoid coil can become very hot during continuous operation.