Skip to content
ATEX/IECEx Zone 2PROFINET S2AirLINE QuickHot Swap

BURKERT 20084696 Type 8652 AirLINE Valve Island

Bürkert Type 8652 AirLINE valve island optimised for process automation. Features LC display diagnostics, safety-related shut-off, AirLINE Quick, and ATEX/IECEx Zone 2 approvals.

BURKERT 20084696 Type 8652 AirLINE Valve Island

Bürkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status.

The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts that prevent unplanned actuation due to pressure peaks.

General Technical Data

Product propertiesDescription
MaterialBody: PA (polyamide)
Seal: NBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Pneumatic intermediate supplyOptional for the variants with 16, 20 and 24 valve slots
Pressure rangeVac...10 bar (Overpressure to atmospheric pressure)
External supply air3...10 bar (auxiliary pilot air)
Flow rate $Q_{Nn}$ value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Flow rate with Hot SwapFlow reduced by approx. 3%
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Nominal current of each valve29 mA (10 mA after power reduction)
Digital inputMax. 48
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C...+55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • Makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20084696 Bürkert Type 8652 AirLINE Quick Adapter in stainless steel or anodised aluminium

Product propertiesDescription
AirLINE Quick Adapter PlateStainless steel 1.4301 or Anodised aluminium
Pneumatic connectionStainless steel 1.4401 or Nickel-plated brass
Valve functions per station8, 16, 24, 32, 40 and 48
Pneumatic Supply / ExhaustPush-in D 10 mm, 3/8"
Pneumatic working portsPush-in D 6 mm, 1/4"

Circuit Functions

Standard Functions

Circuit functionDescription
C (CF C)3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
C (CF C)2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
D (CF D)2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open
H (CF H)5/2-way solenoid valve, Servo-controlled, with manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
L (CF L)5/3-way solenoid valve, With manual override, In middle position all ports locked
M (CF M)5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated
N (CF N)5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted
Z (CF Z)5/2-way solenoid valve, Impulse variant with 2 coils and manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
Circuit functionDescription
C (CF C)3/2-way solenoid valve, Servo-controlled, Normally closed
C (CF C)2 × 3/2-way solenoid valve, Servo-controlled, Normally closed
H (CF H)5/2-way solenoid valve, Servo-controlled. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
L (CF L)5/3-way solenoid valve, Servo-controlled, In middle position all ports locked

Approvals and Conformities

  • Explosion protection: Optional: As a category 3 device suitable for zone 2/22. ATEX: II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc. IECEx: Ex ec IIC Gc / Ex tc IIIC Dc.
  • North America (USA/Canada): Optional: UL Listed (UL 61010-1). Optional: UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Div 2).
  • China Compulsory Certification (CCC): Optional: Products with Ex approval are suitable for import and use for hazardous applications in China.

Explosion Protection Safety Notes

  • Danger from voltage: In an explosive atmosphere, connection terminals for 24 V power supply, SIA, EVS, and digital inputs may only be plugged in or unplugged when de-energised.
  • Hot Swap: The use of the Hot Swap function is prohibited in an explosive atmosphere unless it is ensured by suitable test equipment that no explosive atmosphere is present.
  • Electrostatic charge: Clean the device surface by gently wiping it with a damp or antistatic cloth only to prevent explosion risks.

Dimensions

Variant 4-, 8- and 12-fold

BURKERT 20084696 Bürkert Type 8652 dimensions for 4-, 8- and 12-fold variants

VariantABCmn
4-fold66-4 x M531
8-fold351118 x M572
12-fold7715410 x M5113

Variant 16-, 20- and 24-fold

BURKERT 20084696 Bürkert Type 8652 dimensions for 16-, 20- and 24-fold variants

VariantABCDmm'n
16-fold with intermediate supply11222410 x M5114.3774
20-fold with intermediate supply13426810 x M5158.31175
24-fold with intermediate supply15631210 x M5158.311116
16-fold without intermediate supply9919810 x M5-15-4
20-fold without intermediate supply12124210 x M5-19-5
24-fold without intermediate supply14328610 x M5-23-6

Product Connections

Power Supply Notes

  • Communication and displays: Connect 5-pin spring-loaded terminal (Red: 24 V DC, White: CAN_H, Green: SHIELDING, Blue: CAN_L, Black: GND).
  • Pneumatic valves: The interface plate has a 2-pin spring-loaded terminal (Red: AUX 24 V, Black: GND).

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20084696 Bürkert Type 8652 installation situation inside the control cabinet

Product Design and Assembly

BURKERT 20084696 Bürkert Type 8652 interface plate 24V without modular shut-off

Electronic module with digital inputs (optional)

The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).

Example Configuration

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20084696 Bürkert Type 8652 example network configuration with Industrial Ethernet and büS

Ordering Information

Ordering chart replacement valves (Solenoid valve Type 6534)

Circuit functionNominal diameter$Q_{Nn}$ value AirPressure rangeVoltageArticle no.
C (CF C) 3/2-way, NC4 mm270 l/minVac...10 bar24 V DC20102334
C (CF C) 2x 3/2-way, NC4 mm270 l/minVac...10 bar24 V DC301374
D (CF D) 2x 3/2-way, NO4 mm310 l/minVac...10 bar24 V DC301375
H (CF H) 5/2-way4 mm290 l/minVac...10 bar24 V DC301376
Z (CF Z) 5/2-way, impulse4 mm290 l/minVac...10 bar24 V DC301377
L (CF L) 5/3-way, locked4 mm275 l/minVac...10 bar24 V DC301380
M (CF M) 5/3-way, ventilated4 mm300 l/minVac...10 bar24 V DC301379
N (CF N) 5/3-way, exhausted4 mm300 l/minVac...10 bar24 V DC301381

Ordering chart replacement valves (SIA variant)

Circuit functionNominal diameter$Q_{Nn}$ value AirPressure rangeVoltageArticle no.
C (CF C) 3/2-way, NC4 mm270 l/minVac...10 bar24 V DC20102335
C (CF C) 2x 3/2-way, NC4 mm270 l/minVac...10 bar24 V DC338802
H (CF H) 5/2-way4 mm290 l/minVac...10 bar24 V DC338805
L (CF L) 5/3-way, locked4 mm275 l/minVac...10 bar24 V DC346830