Skip to content
ATEX / IECEx Zone 2PROFINET S2IP20 / IP65

BURKERT 20092328 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island optimised for process automation. Features LC display, pneumatic functions, and ATEX/IECEx Zone 2 approvals.

BURKERT 20092328 8652 AirLINE Valve Island

The BURKERT Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller. This, therefore, enables a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is, of course, also possible. Moreover, key pneumatic functions ensure increased process reliability. For instance, check valves in the exhaust air ducts make sure there is no unplanned actuation due to pressure peaks.

BURKERT 20092328 BURKERT 8652 AirLINE valve island overview

General Technical Data

Product propertiesDescription
Body MaterialPA (polyamide)
Seal MaterialNBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Pressure rangeVac...10 bar
External supply air3...10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C...+55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20092328 BURKERT 8652 AirLINE Quick Adapter in stainless steel or anodised aluminium

Circuit Functions

Circuit functionDescription
C (CF C)3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
D (CF D)2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open
H (CF H)5/2-way solenoid valve, Servo-controlled, with manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
L (CF L)5/3-way solenoid valve, With manual override, In middle position all ports locked
M (CF M)5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated
N (CF N)5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted
Z (CF Z)5/2-way solenoid valve, Impulse variant with 2 coils and manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.

SIA variant (for safety-related shut-off)

Valves Type 6534 for safety-related shut-off (SIA variant) are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants.

Approvals and Conformities

  • Explosion protection: Optional: Explosion protection. As a category 3 device suitable for zone 2/22. ATEX: II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc. IECEx: Ex ec IIC Gc / Ex tc IIIC Dc.
  • North America (USA/Canada): Optional: UL Listed for the USA and Canada (UL 61010-1). Optional: UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Division 2).
  • China Compulsory Certification (CCC): Optional: The products with Ex approval are suitable for import and use for hazardous applications in China.

Safety instructions for potentially explosive areas

To avoid the risk of explosion, the safety instructions in the supplementary manual must be observed in addition to the safety instructions in the operating instructions.

  • Danger due to electrical voltage.
  • Danger of explosion due to electrostatic charge.
  • Danger of injury due to improper installation, operation and maintenance.

Dimensions

Variant 4-, 8- and 12-fold

BURKERT 20092328 BURKERT 8652 Dimensions for 4-, 8- and 12-fold variants

VariantABCmn
4-fold66-4 x M531
8-fold351118 x M572
12-fold7715410 x M5113

Variant 16-, 20- and 24-fold

BURKERT 20092328 BURKERT 8652 Dimensions for 16-, 20- and 24-fold variants

VariantABCDmm'n
16-fold with intermediate supply11222410 x M5114.3774
20-fold with intermediate supply13426810 x M5158.31175
24-fold with intermediate supply15631210 x M5158.311116
16-fold without intermediate supply9919810 x M5-15-4
20-fold without intermediate supply12124210 x M5-19-5
24-fold without intermediate supply14328610 x M5-23-6

Product Installation

Installation situation of the valve terminal inside the control cabinet

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20092328 BURKERT 8652 Installation situation of the valve terminal inside the control cabinet

Example Configuration

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic) as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20092328 BURKERT 8652 Example network configuration with Industrial Ethernet