Skip to content
Direct-actingIP65FKM SealStainless Steel

BURKERT 20107722 Type 7011 Direct-Acting 2/2-Way Plunger Valve, G 1/8, 24V DC

Bürkert 20107722 (Type 7011) direct-acting 2/2-way plunger valve. Features a stainless steel body, G 1/8 internal thread, 1.2 mm orifice, FKM seals, and operates at 24V DC for pressures up to 35 bar.

BURKERT 20107722 Type 7011 Direct-Acting 2/2-Way Plunger Valve, G 1/8, 24V DC

Bürkert 20107722 (Type 7011) is a direct-acting and compact small plunger valve designed for blocking, dosing, filling, and ventilating neutral gaseous and liquid media. This specific model features a stainless steel body, G 1/8 internal thread, 1.2 mm orifice, and FKM seals. It operates at 24V DC and can handle pressures up to 35 bar. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness.

Type 7011 valves feature a slipped-over coil system and allow for simple and fast flange or manifold mounting. In combination with a plug conforming to industry standard form B, the valves satisfy degree of protection IP65.

General Technical Data

FeatureSpecification
OrificeDN 1.2 to DN 2.4 (Model 20107722 is 1.2 mm)
Circuit functionA (Normally closed) and B (Normally open)
Body materialBrass, polyamide (PA), stainless steel 1.4305/303
Seal materialFKM, EPDM
Operating mediumNeutral gases and liquids (e.g., compressed air, water, hydraulic oil, technical vacuum)
Medium temperature-10 °C to +100 °C
Ambient temperatureMax. +55 °C or +75 °C (depending on power level)
ViscosityMax. 21 mm²/s
Operating voltage24 V DC, 24 V 60 Hz, 110 V 50 Hz, 120 V 60 Hz, 230 V 50 Hz, 240 V 60 Hz
Voltage tolerance± 10 %
Duty cycle100 % or 50 % continuous operation (Single valve)
Switching timeOpening: 8...15 ms, Closing: 10...17 ms
Degree of protectionIP65 with cable plug
Installation positionAs required, preferably with actuator upright

Installation Recommendation

The valve can be installed in any position, but it is recommended to mount it with the actuator facing upright to minimize the accumulation of debris in the core tube.

Circuit Functions

  • Circuit function A (CF A): 2/2-way solenoid valve, direct-acting, normally closed.
  • Circuit function B (CF B): 2/2-way solenoid valve, direct-acting, normally open.

Material Specifications

Standard variant circuit function A

Bürkert 20107722 Type 7011 cross-section of standard variant circuit function A

No.ElementMaterial
1NutDIN 176 Surface finish thick film passivated KOSA0101
2StopperStainless steel 1.4113/434
3Core guide tubeStainless steel 1.4303 ST/305L
4Shading ringCopper (optional silver)
5CoreStainless steel 1.4113/434
6SpringStainless steel 1.4310/301
7SealFKM/EPDM
8Valve bodyBrass, stainless steel 1.4305/303, PA (polyamide)
9O-ringFKM/EPDM
10FlangeSurface finish thick film passivated KOSA0101 (brass variant), Nickel-plated surface (stainless steel variant)
11CoilEpoxy

Dimensions

Threaded variant

Note: Dimensions in mm. Variants according to industry standard form B.

Bürkert 20107722 Type 7011 dimensions for threaded variant

Port connectionA [mm]B [mm]C [mm]D [mm]
Thread CF A (M5)M552010
Thread CF A (G 1/8)G 1/882515
Thread CF A (NPT 1/8)NPT 1/872515
Thread CF B (G 1/8)G 1/883414
Thread CF B (NPT 1/8)NPT 1/873414

Electrical Connection

Pin assignment

Bürkert 20107722 Type 7011 electrical pin assignment

Vacuum Applications

In vacuum applications, the existing flow direction must be maintained. Vacuum must therefore always be applied to port A.

Safety Instructions

Risk of injury from high pressure

Before working on the system or device, switch off the pressure and ventilate and empty the lines.

Risk of injury from electric shock

Before working on the system or device, switch off the power supply and secure against reactivation. Always connect the protective conductor and check electrical continuity between the solenoid and the body.

Risk of burns/fire

The solenoid coil can become very hot during continuous operation. Keep the device away from highly flammable substances and media and do not touch with bare hands.