BURKERT 20109612 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island optimised for process automation. Features Industrial Ethernet, PROFINET S2, Hot Swap, and ATEX/IECEx Zone 2 approvals.

BURKERT 20109612 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status.

The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability. For instance, check valves in the exhaust air ducts make sure there is no unplanned actuation due to pressure peaks.

BURKERT 20109612 Burkert 8652 AirLINE valve island overview

Key Features:

  • Safety-related shut-off of valves possible
  • Higher plant availability with PROFINET S2 (system redundancy)
  • Process reliability through pneumatic functions
  • Optimised for installation at the bottom of the control cabinet
  • EX-variants: ATEX / IECEx Zone 2, CCC, cURus HazLoc CL I, II, III Div 2

General Technical Data

Product propertiesDescription
MaterialBody: PA (polyamide)
Seal: NBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum valve functionsMax. 48
Pneumatic intermediate supplyOptional for the variants with 16, 20 and 24 valve slots
Pressure rangeVac...10 bar (Overpressure to atmospheric pressure)
External supply air3...10 bar (auxiliary pilot air)
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Flow rate with Hot SwapFlow reduced by approx. 3%
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Nominal current of each valve29 mA (10 mA after power reduction)
Digital inputMax. 48
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Compressed air qualityISO 8573-1: 2010, Class 7.4.4
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C...+55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet
AirLINE Quick PropertiesDescription
Adapter Plate MaterialStainless steel 1.4301 or Anodised aluminium
Pneumatic connection MaterialStainless steel 1.4401 or Nickel-plated brass
Valve functions per station8, 16, 24, 32, 40 and 48
Pneumatic Supply / ExhaustPush-in D 10 mm, 3/8"
Pneumatic working portsPush-in D 6 mm, 1/4"

BURKERT 20109612 Burkert 8652 AirLINE Quick Adapter in stainless steel or anodised aluminium

Circuit Functions

Standard Functions

  • Circuit function C (CF C): 3/2-way solenoid valve, servo-controlled, with manual override, normally closed.
  • Circuit function C (CF C): 2 × 3/2-way solenoid valve, servo-controlled, with manual override, normally closed.
  • Circuit function D (CF D): 2 × 3/2-way solenoid valve, servo-controlled, with manual override, normally open.
  • Circuit function H (CF H): 5/2-way solenoid valve, servo-controlled, with manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
  • Circuit function L (CF L): 5/3-way solenoid valve, with manual override. In middle position all ports locked.
  • Circuit function M (CF M): 5/3-way solenoid valve, servo-controlled, with manual override. In middle position ports 2 and 4 ventilated.
  • Circuit function N (CF N): 5/3-way solenoid valve, with manual override. In middle position ports 2 and 4 exhausted.
  • Circuit function Z (CF Z): 5/2-way solenoid valve. Impulse variant with 2 coils and manual override.
  • Circuit function C (CF C): 3/2-way solenoid valve, servo-controlled, normally closed.
  • Circuit function C (CF C): 2 × 3/2-way solenoid valve, servo-controlled, normally closed.
  • Circuit function H (CF H): 5/2-way solenoid valve, servo-controlled.
  • Circuit function L (CF L): 5/3-way solenoid valve, servo-controlled. In middle position all ports locked.

Approvals and Conformities

ApprovalDescription
Explosion protectionOptional: As a category 3 device suitable for zone 2/22.
ATEX: BVS 20 ATEX E 031 U (II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc)
IECEx: IECEx BVS 20.0024 U (Ex ec IIC Gc / Ex tc IIIC Dc)
UL Listed (USA/Canada)Optional: UL 61010-1, CAN/CSA-C22.2 No. 61010-1
UL Recognized (Hazardous Locations)Optional: Class I, Zone 2, AEx ec IIC Gc / Ex ec IIC Gc U
Class II, Zone 22, AEx tc IIIC Dc / Ex tc IIIC Dc U
Class I, Division 2, Group A, B, C, D / Class II, III, Division 2, Group F, G
CCCOptional: China Compulsory Certification for hazardous applications in China.

Dimensions

Variant 4-, 8- and 12-fold

VariantABCmn
4-fold66-4 x M531
8-fold351118 x M572
12-fold7715410 x M5113

BURKERT 20109612 Burkert 8652 dimensions for 4-, 8- and 12-fold variants

Variant 16-, 20- and 24-fold

VariantABCDmm'n
16-fold with intermediate supply11222410 x M5114.3774
20-fold with intermediate supply13426810 x M5158.31175
24-fold with intermediate supply15631210 x M5158.311116
16-fold without intermediate supply9919810 x M5-15-4
20-fold without intermediate supply12124210 x M5-19-5
24-fold without intermediate supply14328610 x M5-23-6

BURKERT 20109612 Burkert 8652 dimensions for 16-, 20- and 24-fold variants

Product Connections

Power Supply for Communication and Displays

Connect 5-pin spring-loaded terminal according to the pin assignment (Possible cable cross-section: ≤ 1.5 mm²).

PinColourAssignment
1Red24 V DC
2WhiteCAN_H (büS connection)
3GreenSHIELDING
4BlueCAN_L (büS connection)
5BlackGND

Power Supply for Pneumatic Valves

The interface plate has a 2-pin spring-loaded terminal to which the pneumatic valves’ power supply is connected.

ClipColourAssignment
1RedAUX 24 V
2BlackGND

Fieldbus Interface

Industrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic) or PROFINET S2 – Interface X1 and X2 RJ45

PinAssignment
1TX+
2TX-
3RX+
4N.C.
5N.C.
6RX-
7N.C.
8N.C.

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20109612 Burkert 8652 installation situation inside the control cabinet for Hot Swap

Product Design and Assembly

Electronic Module with Digital Inputs (Optional)

The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.

Possible data3-wire sensors2-wire sensorsMechanical limit switches
Sensor actuatedXXX
Sensor not actuatedXXX
Short circuitX--
Wire break-X-

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).

Module-Based Safety Shutdown (Optional)

Optional connections for module-based safety shutdown: Terminal 1 = valve unit 1, Terminal 2 = valve unit 2, etc. To use the switch-off function, connect the connection to a potential-free contact.

Example Configuration

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20109612 Burkert 8652 example network configuration with Industrial Ethernet and büS

Safety Instructions for Hazardous Locations

DANGER CAUSED BY VOLTAGE

  • Before intervening in the device or the system, switch off the power supply and secure to prevent reactivation.
  • In an existing explosive atmosphere, the connection terminals for 24 V power supply, SIA, EVS, and digital inputs may only be plugged in or unplugged when the power is switched off.
  • The Hot Swap function must not be used in an existing explosive atmosphere.

DANGER OF EXPLOSION CAUSED BY ELECTROSTATIC CHARGE

  • Take appropriate measures to ensure that there are no electrostatic charges in the potentially explosive area.
  • Only clean the device surface by wiping it gently with a damp or antistatic cloth.

SPECIAL CONDITIONS FOR SAFE USE

  • For explosion protection type "ec", install the device in an enclosure that complies with EN/IEC 60079-0 and EN/IEC 60079-7 with a minimum degree of protection of IP54.
  • For explosion protection type "tc" (dust), install the device in an enclosure that complies with EN/IEC 60079-0 and EN/IEC 60079-31 with a minimum degree of protection of IP6X.
  • Only use the device in an area with a pollution degree of at least 2 as defined in IEC 60664-1.
  • Ensure that the set value of the transient protection does not exceed 140% of the rated peak voltage at the supply connections of the device.