BURKERT 20111100 Type 8652 AirLINE Valve Island, 24-Bank, PROFINET

Burkert 20111100 Type 8652 AirLINE valve island for process automation. 24-bank manifold, Industrial Ethernet, Vac to 10 bar, 310 l/min flow rate, ATEX/IECEx Zone 2.

BURKERT 20111100 Type 8652 AirLINE Valve Island, 24-Bank, PROFINET

BURKERT 20111100 Type 8652 AirLINE valve island has been especially developed for process automation requirements. This specific 24-bank configuration features Industrial Ethernet communication and an aluminium AirLINE Quick adapter. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status.

The hardware is optimised for installation at the bottom of the control cabinet. Moreover, key pneumatic functions ensure increased process reliability. For instance, check valves in the exhaust air ducts make sure there is no unplanned actuation due to pressure peaks.

Configuration Details (SKU: 20111100)

This specific model is pre-configured with a 24-slot manifold and specific valve functions to meet complex automation needs.

FeatureSpecification
Number of valve ports24 PCE
Valve positions 1-45/3-way centre position exhausted (WWN)
Valve positions 5-155/2-way monostable (WWH)
Valve position 16Blind plate
Valve positions 17-222x 3/2-way (WWC)
Valve positions 23-24Blind plate
CommunicationIndustrial EtherNet (PROFINET IO, EtherNet IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic)
AirLINE Quick materialAluminium
Pressure portD10 (Brass)
Working portD6 (Brass)

General Technical Data

Product propertiesSpecification
Body MaterialPA (polyamide)
Seal MaterialNBR and PUR
Width per station11 mm
Pressure rangeVac...10 bar
External supply air3...10 bar
Flow rate QnN value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10% tolerance)
Nominal power per valve0.7 W (0.175 W after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Ambient temperature-10 °C...+55 °C
Degree of protectionIP20, IP65 in closed control cabinets

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20111100 AirLINE Quick Adapter in anodised aluminium

Approvals and Conformities

  • Explosion protection: As a category 3 device suitable for zone 2/22. ATEX: II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc. IECEx: Ex ec IIC Gc / Ex tc IIIC Dc.
  • North America (USA/Canada): UL Listed (UL 61010-1) and UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Division 2).
  • China Compulsory Certification (CCC): The products with Ex approval are suitable for import and use for hazardous applications in China.

Safety in Potentially Explosive Areas

To avoid the risk of explosion, the safety instructions in the supplementary manual must be observed. The device must be installed in a suitable control cabinet (minimum IP54 for Category 3G/Gc and IP64 for Category 3D/Dc). Do not connect or disconnect terminals when energized in an explosive atmosphere.

Dimensions

The following dimensions apply to the 16-, 20- and 24-fold variants with intermediate supply.

BURKERT 20111100 Dimensions for 16-, 20- and 24-fold variants

VariantABCDmm'n
24-fold with intermediate supply15631210 x M5158.311116

Product Connections

Industrial Ethernet Interface

For PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic or PROFINET S2, the X1 and X2 RJ45 interfaces are used.

BURKERT 20111100 Industrial Ethernet RJ45 interface

PinAssignment
1TX+
2TX-
3RX+
6RX-

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20111100 Installation situation inside the control cabinet