Burkert 20113472 (Type 8652) AirLINE valve island optimized for process automation. Features 20 valve ports, Industrial Ethernet, AirLINE Quick stainless steel adapter, and ATEX/IECEx Zone 2 approvals.

Burkert 20113472 (Type 8652) AirLINE valve island has been especially developed for process automation requirements. This specific configuration features 20 valve ports, Industrial Ethernet communication (PROFINET IO, EtherNet IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic), and an AirLINE Quick stainless steel adapter with D10 and D6 push-in connections. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. The hardware is optimised for installation at the bottom of the control cabinet, and key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts to prevent unplanned actuation due to pressure peaks.

| Product properties | Description |
|---|---|
| Material | Body: PA (polyamide) Seal: NBR and PUR |
| Width per station | 11 mm |
| Manual override | Latching, spring return (optional: lockable) |
| Number of valve slots | Max. 24 (This configuration: 20) |
| Maximum number of valve functions | Max. 48 |
| Pressure range | Vac...10 bar |
| External supply air | 3...10 bar |
| Flow rate QNn value air | 310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure) |
| Operating voltage | 24 V DC (±10% tolerance) |
| Nominal power of each valve | 0.7 W (0.175 W after power reduction) |
| Protection class | III according to DIN EN 61140, VDE 0140 |
| Operating medium | Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) |
| Degree of protection | IP20, IP65 in closed control cabinets |
| Ambient temperature | -10 °C...+55 °C |
AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.
Advantages:
| Product properties | Description |
|---|---|
| AirLINE Quick Adapter Plate | Stainless steel 1.4301 / Anodised aluminium |
| Pneumatic connection | Stainless steel 1.4401 / Nickel-plated brass |
| Pneumatic Supply / Exhaust | Push-in D 10 mm, 3/8" |
| Pneumatic working ports | Push-in D 6 mm, 1/4" |
| Installation position | Control cabinet wall / Control cabinet floor |

| Circuit function | Description |
|---|---|
| C (CF C) | 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed |
| D (CF D) | 2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open |
| H (CF H) | 5/2-way solenoid valve, Servo-controlled, with manual override |
| L (CF L) | 5/3-way solenoid valve, With manual override, In middle position all ports locked |
| M (CF M) | 5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated |
| N (CF N) | 5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted |
| Z (CF Z) | 5/2-way solenoid valve, Impulse variant with 2 coils and manual override |

Connect 5-pin spring-loaded terminal according to the pin assignment. Possible cable cross-section: ≤ 1.5 mm².
Interface X1 and X2 RJ45 for PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic, or PROFINET S2.

| Pin | Assignment |
|---|---|
| 1 | TX+ |
| 2 | TX- |
| 3 | RX+ |
| 6 | RX- |
| 4, 5, 7, 8 | N.C. |
The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

Explosion Protection Safety Notes (ATEX/IECEx)