Burkert Type 8652 AirLINE valve island (20113963) with 24 valve ports, Industrial Ethernet, AirLINE Quick, and ATEX/IECEx approval for process automation.

Burkert Type 8652 AirLINE valve island (model 20113963) has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet via AirLINE Quick, though installation on a standard rail is also possible. Key pneumatic functions, such as check valves in the exhaust air ducts, ensure increased process reliability by preventing unplanned actuation due to pressure peaks. The product features ATEX/IECEx Zone 2 explosion protection and supports Industrial Ethernet protocols.
| Product properties | Description |
|---|---|
| Material | |
| Body | PA (polyamide) |
| Seal | NBR and PUR |
| Width per station | 11 mm |
| Manual override | Latching, spring return (optional: lockable) |
| Number of valve slots | Max. 24 (24 PCE for model 20113963) |
| Maximum number of valve functions | Max. 48 |
| Pneumatic intermediate supply | Optional for the variants with 16, 20 and 24 valve slots |
| Performance data | |
| Pressure range | Vac...10 bar (-1 to 10 bar) |
| External supply air (auxiliary pilot air) | 3...10 bar |
| Flow rate $Q_{Nn}$ value air | 310 l/min measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure |
| Flow rate $Q_{Nn}$ value air with Hot Swap | Flow reduced by approx. 3% |
| Nominal operating mode | Continuous operation (100 % duty cycle) |
| Electrical data | |
| Operating voltage | 24 V DC (Voltage tolerance ±10%) |
| Nominal power of each valve | 0.7 W (0.175 W after power reduction) |
| Nominal current of each valve | 29 mA (10 mA after power reduction) |
| Digital input | Max. 48 |
| Medium data | |
| Operating medium | Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) |
| Compressed air quality | ISO 8573-1: 2010, Class 7.4.4 |
| Approvals and conformities | |
| Degree of protection | IP20, IP65 in closed control cabinets |
| Type Rating (NEMA 250) | Type 4X in closed enclosures (Type 8652 with stainless steel variant) |
| Environment and installation | |
| Installation position | Any |
| Ambient temperature | -10 °C...+55 °C |
AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.
Advantages:
| Product properties | Description |
|---|---|
| Material | |
| AirLINE Quick Adapter Plate | Stainless steel 1.4301 or Anodised aluminium (Aluminium for model 20113963) |
| Pneumatic connection | Stainless steel 1.4401 or Nickel-plated brass (Brass for model 20113963) |
| Valve functions per station | 8, 16, 24, 32, 40 and 48 |
| Product connections | |
| Pneumatic Supply / Exhaust | Push-in D 10 mm, 3/8" |
| Pneumatic working ports | Push-in D 6 mm, 1/4" |

| Circuit function | Description |
|---|---|
| C (CF C) | 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed |
| C (CF C) | 2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed |
| D (CF D) | 2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open |
| H (CF H) | 5/2-way solenoid valve, Servo-controlled, with manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. |
| L (CF L) | 5/3-way solenoid valve, With manual override, In middle position all ports locked |
| M (CF M) | 5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated |
| N (CF N) | 5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted |
| Z (CF Z) | 5/2-way solenoid valve, Impulse variant with 2 coils and manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. |

| Variant | A | B | C | m | n |
|---|---|---|---|---|---|
| 4-fold | 66 | - | 4 x M5 | 3 | 1 |
| 8-fold | 35 | 111 | 8 x M5 | 7 | 2 |
| 12-fold | 77 | 154 | 10 x M5 | 11 | 3 |

| Variant | A | B | C | D | m | m' | n |
|---|---|---|---|---|---|---|---|
| 16-fold with intermediate supply | 112 | 224 | 10 x M5 | 114.3 | 7 | 7 | 4 |
| 20-fold with intermediate supply | 134 | 268 | 10 x M5 | 158.3 | 11 | 7 | 5 |
| 24-fold with intermediate supply | 156 | 312 | 10 x M5 | 158.3 | 11 | 11 | 6 |
| 16-fold without intermediate supply | 99 | 198 | 10 x M5 | - | 15 | - | 4 |
| 20-fold without intermediate supply | 121 | 242 | 10 x M5 | - | 19 | - | 5 |
| 24-fold without intermediate supply | 143 | 286 | 10 x M5 | - | 23 | - | 6 |
Connect the 5-pin spring-loaded terminal according to the pin assignment (Possible cable cross-section: ≤ 1.5 mm²).
The interface plate has a 2-pin spring-loaded terminal to which the pneumatic valves’ power supply is connected.
For PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic or PROFINET S2 (Interface X1 and X2 RJ45):
To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.


The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).
The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

Danger caused by voltage
Disconnect the power supply before working on the device or system. Secure against reactivation. In an existing explosive atmosphere, connection terminals for 24 V power supply, SIA, EVS, and digital inputs may only be plugged in or unplugged when de-energized.
Risk of explosion due to electrostatic charge
If electrostatically charged devices or persons discharge suddenly, there is a risk of explosion in the potentially explosive area. Only clean the device surface by wiping it gently with a damp or antistatic cloth.
Hot Swap function restrictions
The use of the Hot Swap function is prohibited in an existing explosive atmosphere. If it can be proven and ensured by means of suitable test equipment that there is no explosive atmosphere for a certain period of time, it is permissible to remove/insert valves using Hot Swap during this time.
| Circuit function | Nominal diameter | $Q_{Nn}$ value Air | Pressure range | Voltage | Article no. |
|---|---|---|---|---|---|
| C (CF C) 3/2-way | 4 mm | 270 l/min | Vac...10 bar | 24 V DC | 20102334 |
| C (CF C) 2 × 3/2-way | 4 mm | 270 l/min | Vac...10 bar | 24 V DC | 301374 |
| D (CF D) 2 × 3/2-way | 4 mm | 310 l/min | Vac...10 bar | 24 V DC | 301375 |
| H (CF H) 5/2-way | 4 mm | 290 l/min | Vac...10 bar | 24 V DC | 301376 |
| Z (CF Z) 5/2-way impulse | 4 mm | 290 l/min | Vac...10 bar | 24 V DC | 301377 |
| L (CF L) 5/3-way | 4 mm | 275 l/min | Vac...10 bar | 24 V DC | 301380 |
| M (CF M) 5/3-way | 4 mm | 300 l/min | Vac...10 bar | 24 V DC | 301379 |
| N (CF N) 5/3-way | 4 mm | 300 l/min | Vac...10 bar | 24 V DC | 301381 |
| Dummy valve | - | - | - | - | 335779 |