BURKERT 20121869 Type 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island optimised for process automation. Features up to 48 valve functions, Industrial Ethernet, AirLINE Quick, and ATEX/IECEx Zone 2 approvals.

BURKERT 20121869 Type 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet, though installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts that prevent unplanned actuation due to pressure peaks.

BURKERT 20121869 Burkert Type 8652 AirLINE valve island overview

General Technical Data

Product properties
Material
BodyPA (polyamide)
SealNBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Performance data
Pressure rangeVac...10 bar
External supply air3...10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Nominal operating modeContinuous operation (100 % duty cycle)
Electrical data
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Nominal current of each valve29 mA (10 mA after power reduction)
Medium data
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Compressed air qualityISO 8573-1: 2010, Class 7.4.4
Environment and installation
Ambient temperature-10 °C...+55 °C
Degree of protectionIP20, IP65 in closed control cabinets

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • Makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20121869 Burkert Type 8652 AirLINE Quick Adapter in stainless steel or anodised aluminium

Circuit Functions

SymbolDescription
BURKERT 20121869 Burkert Type 8652 Circuit function C 3/2-way solenoid valveCircuit function C (CF C)
3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
BURKERT 20121869 Burkert Type 8652 Circuit function C 2x 3/2-way solenoid valveCircuit function C (CF C)
2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
BURKERT 20121869 Burkert Type 8652 Circuit function D 2x 3/2-way solenoid valveCircuit function D (CF D)
2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open

Approvals and Conformities

  • Explosion protection: Optional. As a category 3 device suitable for zone 2/22. ATEX: II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc. IECEx: Ex ec IIC Gc / Ex tc IIIC Dc.
  • North America (USA/Canada): Optional UL Listed (UL 61010-1) and UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Division 2).
  • China Compulsory Certification (CCC): Optional. Products with Ex approval are suitable for import and use for hazardous applications in China.

Product Connections

Power supply for communication and displays: Connect 5-pin spring-loaded terminal according to the pin assignment (Red: 24 V DC, White: CAN_H, Green: SHIELDING, Blue: CAN_L, Black: GND).

Power supply for pneumatic valves: The interface plate has a 2-pin spring-loaded terminal to which the pneumatic valves’ power supply is connected (Red: AUX 24 V, Black: GND).

Installation Notes

Hot Swap Function

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20121869 Burkert Type 8652 Installation situation of the valve terminal inside the control cabinet

ATEX/IECEx Safety Instructions

  • Danger from voltage: Before working on the device or system, disconnect the power supply and prevent it from being switched on again.
  • Hot Swap restriction: The use of the Hot Swap function is prohibited in a currently explosive atmosphere. If it can be proven and ensured with suitable test equipment that there is no explosive atmosphere for a certain period of time, it is permissible to remove/insert valves using Hot Swap during this time.
  • Electrostatic charge: Take appropriate measures to ensure that no electrostatic charge can occur in the potentially explosive area. Clean the device surface only by wiping it gently with a damp or antistatic cloth.