BURKERT 20128902 Type 8652 AirLINE Valve Island

Burkert 20128902 Type 8652 AirLINE valve island (16-bank). Features Industrial Ethernet, D10/D6 brass connections, -1 to 10 bar pressure range, and IP20 protection.

BURKERT 20128902 Type 8652 AirLINE Valve Island

BURKERT 20128902 Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller. This enables a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts that prevent unplanned actuation due to pressure peaks.

General Technical Data

Product properties
MaterialBody: PA (polyamide)
Seal: NBR and PUR
Width per station11 mm
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Pressure rangeVac...10 bar
External supply air3...10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C...+55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20128902 Type 8652 AirLINE Quick Adapter

Circuit Functions

SymbolDescription
CF C3/2-way solenoid valve, Servo-controlled, with manual override, Normally closed
CF D2 × 3/2-way solenoid valve, Servo-controlled, with manual override, Normally open
CF H5/2-way solenoid valve, Servo-controlled, with manual override
CF L5/3-way solenoid valve, With manual override, In middle position all ports locked
CF M5/3-way solenoid valve, Servo-controlled, with manual override, In middle position ports 2 and 4 ventilated
CF N5/3-way solenoid valve, With manual override, In middle position ports 2 and 4 exhausted
CF Z5/2-way solenoid valve, Impulse variant with 2 coils and manual override

Approvals and Conformities

  • Explosion protection: Optional ATEX / IECEx Zone 2 (II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc).
  • North America (USA/Canada): Optional UL Listed (UL 61010-1) and UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Div 2).
  • Others: Optional China Compulsory Certification (CCC).

Dimensions

Variant 4-, 8- and 12-fold

BURKERT 20128902 Type 8652 Dimensions 4 to 12 fold

Variant 16-, 20- and 24-fold

BURKERT 20128902 Type 8652 Dimensions 16 to 24 fold

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet. BURKERT 20128902 Type 8652 Installation situation

Product Design and Assembly

Electronic Module with Digital Inputs (Optional)

The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).

Safety Note

For explosion protection variants, do not connect or disconnect when energized. Hot Swap function is prohibited in current explosive environments unless proven safe.