Skip to content
Type 865220 Valve SlotsIndustrial EthernetAirLINE Quick VA40 Digital InputsPneumatic HotSwapIP20 / IP65 Cabinet

BURKERT 20149583 Type 8652 AirLINE 20-Slot Valve Island (Industrial Ethernet, Stainless Steel AirLINE Quick)

BURKERT 20149583 is a Type 8652 AirLINE 20-slot valve island equipped with 15x 2x 3/2-way NC valves, 5 blind plates, stainless steel AirLINE Quick base, Industrial Ethernet, and 40 digital inputs.

BURKERT 20149583 Type 8652 AirLINE 20-Slot Valve Island (Industrial Ethernet, Stainless Steel AirLINE Quick)

BURKERT 20149583 (Type 8652 AirLINE) is a factory-configured 20-slot pneumatic valve island engineered for process automation environments. The unit integrates an AirLINE Quick stainless steel adapter interface, dual-port Industrial Ethernet communications supporting multiple common industrial fieldbus protocols, and five 8-channel digital input modules supplying a total of 40 digital feedback points. Valve positions 1 through 15 are fitted with Type 6534 double 3/2-way servo-assisted normally closed (Circuit Function C) pilot valves, providing 30 active pilot channels, while positions 16 through 20 are secured with dummy blanking plates for future loop expansion. An intermediate pneumatic feed module divides the 20-station manifold to balance air distribution and exhaust capacity.

BURKERT 20149583 Type 8652 AirLINE modular valve island overview

Designed specifically for hygienic processing plants, pharmaceutical skids, and water treatment facilities, the hardware includes pneumatic HotSwap check valves in supply duct 1 (P) and backpressure-inhibiting check valves in exhaust ducts 3 (R) and 5 (S). These mechanisms prevent unintended actuator movement caused by pressure spikes and enable tool-free online pilot valve replacement while the plant remains pressurized.

Slot Allocation and Valve Configuration ​

Article 20149583 utilizes a 20-slot manifold base configured with 11 mm slice-width valves and blanking elements. Active slots contain twin pilot valves to actuate single-acting pneumatic process actuators such as diaphragm or angle-seat valves.

Station RangeComponent TypeCircuit FunctionDescriptionOperating Voltage
Position 1 to 15Type 6534 Solenoid Valve2x 3/2-way CF CServo-assisted, normally closed, with manual override24 V DC (0.7 W / 0.175 W)
Position 16 to 20Dummy Blanking Plate—Closed manifold cover plate for reserve slots—
Intermediate SlotIntermediate Feed Module—Dedicated central supply and exhaust module (1 PCE)—

Each active valve position delivers a standard flow rate $Q_{Nn}$ of 310 l/min air measured at +20 °C, 6 bar inlet pressure, and 1 bar differential pressure. The integrated HotSwap valve reduces flow by approximately 3%. Nominal valve operating mode is 100% continuous duty (ED) with switching times of 15 ms for opening and 15 ms for closing per ISO 12238.

AirLINE Quick Stainless Steel Adapter Interface ​

Article 20149583 includes an AirLINE Quick adapter plate fabricated from 1.4301 stainless steel, fitted with 1.4401 stainless steel push-in fittings. This adapter mounts directly into a cutout on the bottom or side wall of a control cabinet, transitioning pneumatic connections through the cabinet enclosure without individual bulkhead fittings.

BURKERT 20149583 Type 8652 AirLINE Quick stainless steel adapter plate

ParameterSpecification
Adapter Plate MaterialStainless steel 1.4301
Pneumatic Fitting MaterialStainless steel 1.4401
Main Supply Air Connection 1 (P)Push-in connector D10 mm
Working Outlets 2 and 4Push-in connectors D6 mm
Auxiliary Pilot Air ConnectionInternal pilot air routing
Ingress Protection (Cabinet Interface)IP65 according to EN 60529; NEMA 250 Type 4X in closed enclosures
Mounting LocationCabinet floor or cabinet wall

Advantages of Floor-Mounting

Direct AirLINE Quick mounting eliminates panel-feedthrough tubing, minimizes enclosure volume, and protects electrical modules within the clean cabinet interior while exposing only stainless steel pneumatic ports to the washdown area.

Fieldbus Communications and Electrical Architecture ​

The valve island communication module operates on Industrial Ethernet supporting PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic via two RJ45 ports (X1 and X2). PROFINET S2 system redundancy is supported for high-availability distributed control systems.

BURKERT 20149583 Type 8652 Industrial Ethernet RJ45 communication ports X1 and X2

Industrial Ethernet RJ45 Pin Assignment (Ports X1 and X2) ​

PinSignalDescription
1TX+Transmit Data +
2TX-Transmit Data -
3RX+Receive Data +
4N.C.Not connected
5N.C.Not connected
6RX-Receive Data -
7N.C.Not connected
8N.C.Not connected

Power Supply Separation ​

The island requires two independent 24 V DC power sources to isolate communication circuits from inductive valve load switching.

  • Communication and Logic (5-pin spring-loaded terminal): Red: 24 V DC; White: CAN_H (büS); Green: Shielding; Blue: CAN_L (büS); Black: GND (0 V DC). Maximum wire cross-section is 1.5 mm².
  • Pneumatic Valve Actuation (2-pin spring-loaded terminal): Clip 1 (Red): AUX 24 V DC; Clip 2 (Black): GND (0 V DC). Valve coil rated current is 29 mA, dropping to 10 mA after internal electronic power reduction.

Electrical Safety Note

Ensure independent power supplies for communications and pneumatic valves. Never parallel the AUX 24 V valve coil supply directly from the logic supply terminal, as switching transients may affect fieldbus communication.

Digital Input Modules (40 DI Configuration) ​

Article 20149583 incorporates five 8DI electronic modules, yielding 40 digital inputs for process valve limit switches and inductive proximity sensors. Sensor power (24 V DC) is provided directly by the modules, with current limited to 30 mA per channel.

BURKERT 20149583 Type 8652 electronic module terminal wiring for digital inputs

Electrical ParameterValue
Supported Sensor Types2-wire sensors, 3-wire sensors, mechanical limit switches
Switching Thresholds$V_{\text{OFF}} = 0\dots5\text{ V}$, $V_{\text{ON}} = 10\dots30\text{ V}$
Input Current at $V_{\text{ON}}$Max. 5.7 mA per channel (typical at 24 V DC)
Input Impedance> 4 kΩ
Galvanic IsolationNo (all channels share common reference potential)
Maximum Cable Length< 30 m (wire cross-section $\le 1.5\text{ mm}^2$)
Diagnostic CapabilityWire-break detection (2-wire sensors); Short-circuit detection (3-wire sensors)

Sensor Diagnostics Feedback Matrix ​

Channel Diagnostic State3-Wire Sensor2-Wire SensorMechanical Switch
Sensor ActuatedSupportedSupportedSupported
Sensor Not ActuatedSupportedSupportedSupported
Short Circuit DetectionSupported——
Wire Break Detection—Supported—

Network Topology and System Integration ​

When equipped with the Industrial Ethernet gateway, Type 8652 functions as an Ethernet fieldbus master node. Additional Type 8652 islands fitted with büS (CANopen-based) interface modules can be connected downstream as slave islands via M12 büS cabling, forming a unified network segment.

BURKERT 20149583 Type 8652 Industrial Ethernet network topology with büS slave islands

Device parameters, process diagnostics, and cycle-count monitoring are accessible locally via the built-in monochrome LC display or remotely via Bürkert Communicator software (Type 8920) connected through a USB-büS interface.

Dimensional Data and Control Cabinet Installation ​

For a 20-slot configuration with intermediate pneumatic supply, the overall manifold dimensions and mounting hole coordinates are defined as follows (all dimensions in mm):

BURKERT 20149583 Type 8652 dimensional drawing for 20-slot variant with intermediate feed

Configuration VariantABCDm$m'$n
20-slot with Intermediate Supply134 mm268 mm10x M5158.3 mm1175

Mounting is supported via EN 50022 standard DIN rails (35 x 7.5 mm or 35 x 15 mm) or through direct baseplate bolting using M5 fasteners.

BURKERT 20149583 Type 8652 control cabinet installation clearance for Hot Swap operation

Hot Swap Maintenance Clearance

Maintain minimum vertical and front-edge clearance inside the control cabinet to allow insertion and removal of the 11 mm pilot valve bodies without striking cabinet doors or wire ducts during live operation.

Approvals and Hazardous Location Safety ​

Type 8652 valve islands conform to European Directives and hold certifications for hazardous industrial installations when installed in suitable external enclosures:

  • ATEX / IECEx Zone 2/22: BVS 20 ATEX E 031 U, IECEx BVS 20.0024 U; Marking: II 3G Ex ec IIC Gc and II 3D Ex tc IIIC Dc.
  • North America: cURus Listed per UL 61010-1 and CAN/CSA-C22.2 No. 61010-1; cURus HazLoc Class I, Zone 2, AEx ec IIC Gc / Class II, Zone 22, AEx tc IIIC Dc; Class I, Division 2, Groups A, B, C, D / Class II, III, Division 2, Groups F, G.
  • China Compulsory Certification (CCC): Certified according to GB/T 3836 series for hazardous locations.

Hazardous Area Operating Rules

When installed in explosive gas or dust atmospheres, the valve island must be housed in an enclosure rated at least IP54 (for 3G gas) or IP6X (for 3D dust). Terminal plugs, including 24 V power and digital input connectors, must never be connected or disconnected while energized unless the atmosphere is confirmed to be non-hazardous. HotSwap valve exchange is prohibited in hazardous locations while an explosive atmosphere is present.

Compatible Spare Parts and Accessories ​

Item DescriptionArticle / Ident Number
Replacement Valve Type 6534 (2x 3/2-way CF C, NC, 24 V DC, incl. screws)Article 301374 (REF 296031)
Replacement Dummy Blanking Valve Plate (incl. screws)Article 335779 (REF 327614)
8-Channel Digital Input Electronic Module (8DI)Article 384872
5-Pin Spring-Loaded Terminal Plug (Communication and Display Power)Article 920180
2-Pin Spring-Loaded Terminal Plug (Pneumatic Valve Coil Power)Article 920442
M5 x 10 A2 DIN 6912 Fastener Set (Pack of 10)Article 308661
Height Adapter for 20-Slot Base with Intermediate FeedArticle 754963
External Retaining Plate for 20-Slot Base with Intermediate FeedArticle 60005569
Blind Plate for 20-Slot Base with Intermediate FeedArticle 754968
Bürkert Communicator PC Interface Kit 1 (Type 8923 USB-to-büS with terminating resistor)Article 772426