Skip to content
Type 2934DN 15Size 8EPDM High-Temp1.4435 / 316L0-10 barASME BPE WeldedCIP / SIP

BURKERT 20150331 Type 2934 Manual T-Diaphragm Valve DN 15 Welded ASME BPE

BURKERT 20150331 Type 2934 is a manual basic T-diaphragm valve featuring a 1.4435/316L block body, DN 15 ASME BPE weld ends, size 8 high-temperature EPDM diaphragm, and 0-10 bar operating pressure.

BURKERT 20150331 Type 2934 Manual T-Diaphragm Valve DN 15 Welded ASME BPE

BURKERT 20150331 Type 2934 is a manually operated basic T-diaphragm valve designed for shut-off control in ultra-pure, hygienic, and sterile fluid processing applications. Built around a zero-dead-leg stainless steel block body machined from 1.4435 (316L), this configuration integrates diaphragm size 8 with ASME BPE / DIN 11866 Series C welded ends (main run DN 15 with 12.7 x 1.65 mm tube dimensions; branch port 9.53 x 0.89 mm). The valve is fitted with a high-temperature EPDM diaphragm rated from -10 °C to +143 °C and sustains static operating pressures up to 10 bar.

BURKERT 20150331 Type 2934 diaphragm valve with welded T-body

Equipped with a compact manual actuator consisting of a polyphenylene sulphide (PPS) handwheel and a stainless steel bonnet, the unit provides chemical resistance and autoclavability up to +130 °C. The valve features an integrated optical position indicator and an internal mechanical stroke limiter configured as a closing stop to protect the elastomer diaphragm against mechanical over-compression.

Technical Specifications & Operating Limits ​

ParameterSpecification Details
Valve Type / FamilyType 2934 (T-diaphragm valve with manually operated basic actuator)
Article Number (SKU)20150331
Diaphragm SizeSize 8
Main Port 1 DimensionsDN 15 (NPS 1/2) – 12.7 mm outer diameter x 1.65 mm wall thickness
Branch Port 2 Dimensions9.53 mm outer diameter x 0.89 mm wall thickness
Connection StandardWelded connection to ASME BPE / DIN 11866 Series C
Medium Pressure Range0.00 bar to 10.00 bar
Nominal Pressure ClassPN 16 (DIN EN 1333) / Class 150 (DIN EN 1759)
Medium Temperature Range-10 °C to +143 °C (steam sterilisation up to +150 °C for 60 minutes)
Ambient Temperature Range-10 °C to +130 °C (autoclavable; short-term up to +150 °C)
Handwheel Diameter35 mm (Handwheel size T / Tiny; spindle slope 1.5 mm per rotation)
Handwheel MaterialPolyphenylene sulphide (PPS)
Bonnet MaterialStainless steel 1.4308
Valve Body MaterialStainless steel block material 1.4435 (DIN EN 10088) / 316L (ASTM A479/A479M)
Diaphragm MaterialHigh-temperature EPDM (Bürkert code AD / E04)
Diaphragm FasteningButtoned attachment
Internal Finish QualityMechanically polished Ra ≤ 0.5 µm (SF1) / Electropolished Ra ≤ 0.38 µm (SF4)
External Finish QualityRa ≤ 1.6 µm
Regulatory ConformityFDA 21 CFR 177.2600, (EC) 1935/2004, USP Class VI, 3-A Sanitary compliant

Component Materials & Construction ​

BURKERT 20150331 Type 2934 manual diaphragm valve material specifications and component overview

The Type 2934 valve assembly consists of six structural and operational components engineered for sterile containment:

  1. Handwheel: Polyphenylene sulphide (PPS) or precision cast stainless steel 1.4308 (PPS fitted on model 20150331).
  2. Visual Position Indicator: Polyamide (PA) marker ring revealing open stroke position below the handwheel.
  3. Valve Spindle: Stainless steel 1.4305 transferring rotational motion into linear thrust.
  4. Diaphragm Bonnet: Stainless steel 1.4308 housing internal drive threads, relief bores, and sensor ports.
  5. Diaphragm: High-temperature vulcanised EPDM elastomer with integral button vulcanised for mounting.
  6. Valve Body: Monoblock forged/machined 1.4435 stainless steel (316L equivalent) with low ferrite content.

INFO

Surfaces in contact with process media comply with ASME BPE SF4 requirements, featuring electropolished finishes down to Ra ≤ 0.38 µm. External surfaces maintain Ra ≤ 1.6 µm for ease of wipe-down cleaning.

Actuator Operation & Handwheel Torque Limits ​

Manual actuation is executed by rotating the PPS handwheel. Turning counterclockwise lifts the spindle and compressor, unseating the EPDM diaphragm and exposing the yellow visual indicator ring located below the handwheel rim. Turning clockwise lowers the compressor until the diaphragm seals across the body weir.

Excessive torque on the handwheel causes premature fatigue and permanent indentation of the elastomer seal. To achieve tight shut-off without damaging the diaphragm size 8 seat, observe the tightening torque limits:

Operating ConditionMedia PressureDiaphragm Size 8 EPDM Handwheel Torque
Static Tightness (pressurised on one seat side)10 bar0.6 Nm (+10% tolerance)
Dynamic Tightness (flowing media through seat)10 bar0.9 Nm (+10% tolerance)

TIP

Do not force the handwheel past the point where the valve achieves fluid-tight sealing. Visibility of the yellow position marker does not correlate directly with the closed seating point.

Setting the Minimum Stroke Limiter ​

Type 2934 basic actuators incorporate an adjustable minimum stroke limiter, functioning as an integrated mechanical closing stop to prevent diaphragm crush.

BURKERT 20150331 Type 2934 minimum stroke limiter setting for diaphragm size 8

Adjustment procedure for diaphragm size 8:

  1. Rotate the handwheel clockwise until the valve reaches the required closed position.
  2. Loosen the retaining screw on the handwheel using a 2 mm hexagon socket wrench, then lift off the handwheel.
  3. Thread the internal hexagon nut down onto the spindle as far as it will travel. The minimum stroke stop is now established.
  4. Reinstall the handwheel, ensuring the square shaft of the spindle and the hexagon head of the stop nut seat cleanly within the handwheel cavity.
  5. Tighten the handwheel central screw with a torque of 0.9 Nm. If required, apply threadlocking adhesive to ensure permanent fixation.

WARNING

Do not thread the hexagon stop nut into the square region of the spindle. The minimum stroke limiter must only be applied within the 0% to 25% opening stroke range.

Welded T-Body Dimensions ​

BURKERT 20150331 Type 2934 welded T-body dimensional diagram

The T-valve block body eliminates dead legs by branching the diaphragm shut-off port directly off the main distribution line.

Parameter DimensionSymbolValue (mm)
Main Port Outside Diameter∅ D119.05 mm (Port 1 nominal size) / 12.70 mm
Main Port Wall Thicknesss11.65 mm
Branch Port Outside Diameter∅ D29.53 mm / 6.35 mm
Branch Port Wall Thicknesss20.89 mm
Overall Body LengthA88.0 mm
Center-to-Port LengthB25.0 mm
Actuator Seating CenterlineC49.90 mm – 53.00 mm
Body Face-to-Weld DistanceE20.0 mm
Body WidthF61.0 mm – 68.0 mm
Bonnet Flange DimensionG32.0 mm – 38.0 mm
Branch Center HeightH20.0 mm – 23.0 mm
Port OffsetI10.0 mm – 13.0 mm
Actuator Height OpenH154.0 mm
Actuator Height ClosedH249.0 mm
Handwheel Outer Diameter∅ B35.0 mm

Installation Guidelines & Pipeline Welding ​

BURKERT 20150331 Type 2934 recommended installation orientations in pipeline systems

To ensure proper self-draining and prevent contamination in sterile loops, Type 2934 T-valves must be mounted with consideration of flow orientation and drainage inclinations per ASME BPE.

DANGER

Prior to performing any mechanical or welding work, depressurise the entire pipeline system and vent or drain all processing media. Failure to vent media can cause severe burns or pressure release.

Welding and Assembly Protocol ​

  • Actuator Disassembly: The manual actuator and EPDM diaphragm must be completely removed from the stainless steel body before welding the body into the line. Thermal conduction during orbital or manual welding will destroy the polymer diaphragm and bonnet seals.
  • Body Welding: Weld the 1.4435 block body into the piping loop adhering to ASME Section VIII Division 1 guidelines. Ensure the pipe runs are aligned without mechanical tension or induced vibration.
  • Relief Bore Positioning: When reassembling the bonnet, position at least one of the diaphragm monitoring relief bores at the lowest gravitational point to facilitate rapid leakage detection.
  • Screw Tightening Torque: When reinstalling the actuator onto the valve body, tighten the body bolts in three progressive stages (approx. 1/3, 2/3, and 3/3 of final torque) in a crosswise sequence. For diaphragm size 8, the required final tightening torque is 2.0 Nm (+10% tolerance).

Diaphragm Replacement & Maintenance ​

BURKERT 20150331 Type 2934 actuator and diaphragm dismantling and replacement assembly

Under normal operating conditions with compatible fluids, the manual actuator is maintenance-free. Regular inspection of the bonnet leakage relief bores is required to detect early diaphragm wear.

Maintenance Intervals ​

  • Post-Sterilisation Check: Retighten the four body fastening screws crosswise after the initial steam sterilisation cycle.
  • Wear Inspection: Inspect the EPDM diaphragm for cracking, swelling, or embrittlement after a maximum of 100,000 switching cycles. Slurries or abrasive process fluids mandate shorter inspection periods.

Replacing the Size 8 Diaphragm ​

  1. Rotate the handwheel counterclockwise into the fully OPEN position.
  2. Loosen the four body fastening screws crosswise and withdraw the actuator and diaphragm assembly from the body.
  3. Rotate the handwheel clockwise to the CLOSED position, driving the compressor forward.
  4. Unbutton the worn EPDM diaphragm from the compressor cup.
  5. Press the button stud of the replacement EPDM diaphragm (article 688421) into the compressor socket until fully seated.
  6. Return the handwheel to the OPEN position.
  7. Align the diaphragm identification tab at a 90° angle relative to the pipeline flow axis.
  8. Place the actuator assembly back onto the block body. Tighten screws loosely in a crosswise pattern.
  9. Cycle the handwheel open and closed twice to seat the elastomer correctly across the weir, then reopen approximately 20% before tightening the screws crosswise in 3 stages to 2.0 Nm.

ATEX and Safety Specifications ​

When ordered with optional code PX51, Type 2934 diaphragm valves comply with ATEX directive 2014/34/EU and IECEx certification (EPS 18 ATEX 2 008 X / IECEx EPS 18.0007 X: II 2G Ex h IIC T4...T2 Gb / II 2D Ex h IIIC T135 °C...T300 °C Db), classified as non-electrical Category 2 mechanical equipment suitable for Zone 1/21 and Zone 2/22.

WARNING

To prevent hazardous electrostatic discharge in potentially explosive atmospheres:

  • Establish potential equalization by grounding the stainless steel valve body directly to the plant pipework.
  • Clean external plastic and metallic surfaces only using a damp or antistatic cloth.
  • Strictly observe flow velocity restrictions for low-conductivity fluids (≤ 100 pS/m requires flow velocities ≤ 1 m/s per IEC 60079-32-1).

Position feedback can be retrofitted by installing an inductive proximity sensor (order code 550412 for standard M5, or 904779 for ATEX M5) into the dedicated threaded tap in the stainless steel bonnet to detect the mechanical position of the internal compressor.