Skip to content
2x3/2-Way24V DCDN 4.0PN 2.5-10 bar

BURKERT 204710 Type 6524 2x3/2-Way Solenoid Valve, 24V DC

Burkert Type 6524 (Model 204710) 2x3/2-way pneumatic solenoid valve. Features 4.0mm orifice, 24V DC, 2.5-10 bar pressure range, and manual override.

BURKERT 204710 Type 6524 2x3/2-Way Solenoid Valve, 24V DC

BURKERT Type 6524 (Model 204710) is a 2 × 3/2-way solenoid valve designed for pneumatic applications. The 2 × 3/2-way valve variant is a combination of two pilot flipper solenoid valves Type 6144 and one pneumatic seat valve. The flipper action system allows the switching of high pressures combined with low power consumption and short switching times.

BURKERT 204710 Type 6524 solenoid valve exterior view

This compact valve features a 4.0 mm orifice, operates on 24V DC, and handles a pressure range of 2.5 to 10 bar. It is equipped with a manual override as standard, facilitating easy testing and maintenance.

General Technical Data

PropertyValue
Material (Seal)FKM, NBR, PUR
Material (Body)PPS, polyamide
Weight40 g (2 × 3/2-way)
Manual overrideStandard
OrificeDN 4.0
Duty cycle100 % continuous operation
Switching frequencyApprox. 1000 c.p.m.
Switching timeOpening: <10 ms, Closing: <10 ms
Operating voltage24 V DC (±10 % voltage tolerance)
Nominal power2 × 0.8 W
Operating mediumLubricated or oil-free compressed dry air, neutral gases (5 μm filter recommended)
Medium temperature-10 °C...+50 °C
Ambient temperature-10 °C...+55 °C
Electrical connectionRectangular plug with 3 pins, raster 2.54 mm
Degree of protectionIP40 with rectangular cable plug

Circuit Function

Circuit function C (CF C) - 2 × 3/2-way solenoid valve Servo-controlled, with manual override, normally closed.

BURKERT 204710 circuit function C 2x3/2-way diagram

Dimensions

The following dimensional drawing applies to the standard 2 × 3/2-way variant (dimensions in mm).

BURKERT 204710 standard variant 2x3/2-way dimensions

Product Design and Assembly

The 2 × 3/2-way variant is assembled using two pilot controls and a shared pneumatic seat valve body.

BURKERT 204710 product assembly 2x3/2-way

Installation and Operation

Safety Instructions

  • Risk of injury due to high pressure: Switch off the pressure before working on the device or system. Vent or empty the lines.
  • Risk of injury from electric shock: Switch off the power supply before working on the device or system. Secure against reactivation.
  • Uncontrolled movement: Back pressure in the exhaust air ducts can cause uncontrolled movements of the actuators. Use large-volume silencers.

Manual Override

To operate the valve manually, turn the manual override 90° in the direction of the arrow. This puts the valve into the switched state. The valve remains fixed in the switched state until the manual override is turned back to its original position.

For the double valve 2x3/2-way, the upper manual override switches output 2(A) while the lower manual override switches output 4(B).

BURKERT 204710 manual override operation

Electrical Installation Note

Observe the type plate information on voltage, electrical power, and current type. At 100% duty cycle and maximum ambient temperature, the coil heats up to approx. +105 °C in single assembly and to approx. +120 °C in block assembly.