Burkert 23541 (Type 0331) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve with a flange connection, ideal for aggressive media.

BURKERT 23541 (Type 0331) is a direct-acting, media-separated pivoted armature valve designed for controlling, shutting off, and dosing neutral and aggressive media. Available in 2/2 and 3/2-way variants, this specific model is a 3/2-way normally closed valve (Circuit Function C) featuring a Bürkert-specific flange connection (SFB). The solenoid actuator and the medium chamber are separated by a diaphragm system, making it highly suitable for critical media such as aggressive acids and lyes.
The solenoid coils are moulded with a chemically resistant epoxy. The Type 0331 series is equipped with a service-friendly, robust manual override for start-up and testing.
| Product Properties | Specification |
|---|---|
| Orifice | DN 2...DN 4 (Model 23541: 3.00 mm) |
| Circuit function | A, B, C, D, E, F and T (Model 23541: C - normally closed) |
| Body material | Brass, Stainless steel (1.4401), PP, PEEK (Model 23541: Stainless steel) |
| Seal material | EPDM, FKM, FFKM, NBR (Model 23541: EPDM) |
| Thermal insulation class | Epoxy coil class H |
| Duty cycle | 100% continuous operation (for brass and stainless steel) |
| Voltage | 24 V DC (Model 23541), 24 V 50 Hz, 110 V 50 Hz, 230 V 50 Hz, 120 V 60 Hz, 240 V 60 Hz |
| Voltage tolerance | ±10% |
| Port connection | Flange interface according to Bürkert standard |
| Degree of protection | IP65 with cable plug |
| Installation position | As required, preferably with actuator upright |
| Ambient temperature | Max. +55 °C |
TIP
For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet.
| Symbol | Description |
|---|---|
![]() | Circuit function A (CF A) 2/2-way solenoid valve Direct-acting Normally closed |
![]() | Circuit function B (CF B) 2/2-way solenoid valve Direct-acting Normally open |
![]() | Circuit function C (CF C) 3/2-way solenoid valve Direct-acting Normally closed |
![]() | Circuit function D (CF D) 3/2-way solenoid valve Direct-acting Normally open |
![]() | Circuit function E (CF E) 3/2-way mixing valve (solenoid valve) |
![]() | Circuit function F (CF F) 3/2-way distribution valve (solenoid valve) Direct-acting |
![]() | Circuit function T (CF T) 3/2-way solenoid valve Direct-acting Flow direction optional Normally closed |

| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Diaphragm | EPDM, FKM, FFKM, NBR |
| 3 | O-ring | EPDM, FKM, FFKM, NBR |
| 4 | Seat | Brass, Stainless steel (1.4401), PP, PEEK |
| 5 | Valve body | Brass, Stainless steel (1.4401), PP, PEEK |
Pressure range and flow rate (Standard variant - Brass, stainless steel or PEEK body)
| Circuit function | DN | Kv value water DC [m³/h] | Kv value water AC [m³/h] | Pressure range Standard [bar] | Pressure range Vacuum [bar] |
|---|---|---|---|---|---|
| A / B / C / D / F | 2 | 0.08 | 0.10 | 0...16 | -0.98...10 |
| A / B / C / D / F | 3 | 0.12 | 0.15 | 0...10 | -0.98...6 |
| A / B / C / D / F | 4 | 0.15 | 0.18 | 0...5 | -0.98...3 |
| E | 2 | 0.08 | 0.10 | 0...10 | -0.98...8 |
| E | 3 | 0.12 | 0.15 | 0...6 | -0.98...5 |
| E | 4 | 0.15 | 0.18 | 0...3 | -0.98...2.5 |
| T | 2 | 0.08 | 0.10 | 0...12 | -0.98...8 |
| T | 3 | 0.12 | 0.15 | 0...8 | -0.98...5 |
| T | 4 | 0.15 | 0.18 | 0...4 | -0.98...3 |
WARNING
Devices with FKM and/or FFKM diaphragms are reduced to a maximum pressure of 12 bar.
Explore similar products in our catalog