Skip to content
12 Valve SlotsbüS / CANopenAirLINE Quick AluminiumD10 / D6 Brass Ports-1 to 10 barATEX / IECEx Zone 2/22

BURKERT 309093 Type 8652 AirLINE 12-Slot Valve Island (büS/CANopen, AirLINE Quick)

BURKERT 309093 (Type 8652) is a 12-slot AirLINE valve island featuring büS/CANopen communication, AirLINE Quick aluminium adapter plate, brass D10/D6 push-in ports, vacuum to 10 bar operation, and IP20/IP65 protection.

BURKERT 309093 Type 8652 AirLINE 12-Slot Valve Island (büS/CANopen, AirLINE Quick)

BURKERT 309093 (Type 8652) is a 12-slot AirLINE valve island configured with an AirLINE Quick anodised aluminium adapter plate and a 5-pin büS/CANopen communication interface. Developed for process automation, the assembly integrates twelve 11 mm solenoid valve positions consisting of six dual 3/2-way normally closed valves (Circuit Function C) and six 5/2-way monostable valves (Circuit Function H), delivering individual nominal flow rates up to 310 l/min.

The hardware design is optimized for direct installation onto the control cabinet floor or wall using the AirLINE Quick adapter, eliminating intermediate bulkhead fittings and significantly reducing cabinet volume requirements. Process safety features include external auxiliary pilot air supply operating between 3 and 10 bar, working pressure capabilities from vacuum down to -1.00 bar up to 10.00 bar, and integrated diagnostics reported on the local LC display as well as cyclically to the supervisory fieldbus controller.

Technical Specifications ​

Technical PropertySpecification Value
Product TypeValve island Type 8652 AirLINE
Article Number309093
Modular Platform VariantFieldbus module (Standard)
Number of Valve Slots12 PCE
Width per Station11 mm
Body MaterialPolyamide (PA)
Seal MaterialNBR and PUR
AirLINE Quick Adapter MaterialAnodised aluminium
Supply Connection Port 1Push-in D10 mm, nickel-plated brass
Working Ports 2 and 4Push-in D6 mm, nickel-plated brass
Auxiliary Pilot Air ConnectionExternal, 3...10 bar
Nominal Operating Pressure-1.00 bar...10.00 bar (vacuum to 10 bar)
Nominal Flow Rate QNn (Air)Up to 310 l/min (measured at +20 °C, 6 bar inlet, 1 bar pressure drop)
Operating MediumOil-free or lubricated compressed dry air, neutral gases (5 µm filtration recommended)
Compressed Air QualityISO 8573-1: 2010, Class 7.4.4
Operating Voltage24 V DC (±10%), residual ripple 1 Vss
Nominal Power per Valve0.7 W (0.175 W after internal electronic power reduction)
Nominal Current per Valve29 mA (10 mA after power reduction)
Communication ProtocolbüS / CANopen
Communication Hardware5-pin spring-loaded terminal strip
Valve Power Hardware2-pin spring-loaded terminal strip (AUX 24 V DC)
Protection ClassIII according to DIN EN 61140, VDE 0140
Degree of ProtectionIP20 bare; IP65 mounted with AirLINE Quick in closed control cabinet
NEMA Enclosure RatingType 4X in closed enclosures (stainless steel variant)
Ambient & Medium Temperature-10 °C...+55 °C
Storage Temperature-20 °C...+60 °C
Digital Input Modules0 (without DI electronic module)
Intermediate Air Feed0 PCE (without intermediate supply module)

Valve Slot Configuration (Article 309093) ​

Article 309093 is delivered fully assembled and factory tested with twelve Type 6534 pilot solenoid valves mapped across positions 1 through 12:

Slot PositionCircuit FunctionValve ConstructionNormal PositionPort SizesOperating Pressure
Slot 1CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 2CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 3CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 4CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 5CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 6CF-C2x 3/2-way solenoid valveNormally closedD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 7CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 8CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 9CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 10CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 11CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)
Slot 12CF-H5/2-way solenoid valveMonostableD6 push-inVac...10 bar (pilot 3...10 bar)

Circuit Functions ​

The Type 8652 platform supports standardized pilot pneumatic circuit functions based on Type 6534 solenoid valves. Article 309093 implements Circuit Functions C and H as primary control elements:

  • Circuit Function C (CF C): Dual 3/2-way solenoid valve, servo-assisted, normally closed in de-energised state. Each station controls two independent single-acting actuators. Nominal flow rate QNn is 270 l/min air.
  • Circuit Function H (CF H): 5/2-way solenoid valve, servo-assisted, monostable with spring return. Pressure applied at port 1 directs air to port 2 or 4, controlling double-acting actuators. Nominal flow rate QNn is 290 l/min air.
  • Circuit Function D (CF D): Dual 3/2-way solenoid valve, servo-assisted, normally open. Nominal flow rate QNn is 310 l/min air.
  • Circuit Function L (CF L): 5/3-way solenoid valve, servo-assisted, middle position closed (all ports locked). Nominal flow rate QNn is 275 l/min air.
  • Circuit Function M (CF M): 5/3-way solenoid valve, servo-assisted, middle position pressurized (ports 2 and 4 ventilated). Nominal flow rate QNn is 300 l/min air.
  • Circuit Function N (CF N): 5/3-way solenoid valve, servo-assisted, middle position exhausted (ports 2 and 4 exhausted). Nominal flow rate QNn is 300 l/min air.
  • Circuit Function Z (CF Z): 5/2-way solenoid valve, bistable impulse variant with 2 solenoid coils. Nominal flow rate QNn is 290 l/min air.

All standard valves include manual overrides with latching and spring-return operation.

AirLINE Quick Adapter Plate ​

AirLINE Quick allows direct flush mounting of the valve terminal onto the control cabinet floor or wall, penetrating the enclosure boundary with sealed pneumatic connections.

BURKERT 309093 AirLINE Quick adapter plate in anodised aluminium

AirLINE Quick Features ​

  • Reduces internal cabinet space consumption by eliminating internal pneumatic distribution tubing.
  • Direct hose connections at the cabinet floor reduce installation hours and field routing errors.
  • Adapter plate manufactured from anodised aluminium (article 309093) or optional stainless steel 1.4301.
  • Pneumatic connections fitted with nickel-plated brass push-in fittings: D10 mm for supply/exhaust and D6 mm for working ports.

Dimensions and Installation Geometry ​

BURKERT 309093 Type 8652 dimensions for 4, 8, and 12 valve slots

Dimensions for 4-, 8-, and 12-slot configurations without intermediate supply:

VariantDimension A (mm)Dimension B (mm)Mounting Cm (Stations)n (Base Elements)
4-fold66—4 x M531
8-fold351118 x M572
12-fold (Article 309093)7715410 x M5113

For 16-, 20-, and 24-slot platforms, the terminal expands modularly with optional intermediate supply blocks (dimension D = 114.3 mm or 158.3 mm) and up to 10 x M5 mounting points.

BURKERT 309093 Type 8652 modular assembly and interface plate

Mounting is supported either directly on a standard DIN rail conforming to EN 50022 (35 x 7.5 mm or 35 x 15 mm) or via the AirLINE Quick cutout on the control cabinet base.

Electrical and Bus Connections ​

Article 309093 operates with dedicated galvanic separation between fieldbus communication electronics and pneumatic solenoid power circuits.

BURKERT 309093 büS and CANopen terminal layout

büS / CANopen 5-Pin Spring Terminal Strip ​

The 5-pin spring terminal provides power to the internal communications processor, display unit, and CAN-based büS line:

Pin PositionTerminal MarkingCore ColourSignal Assignment
Pin 1+24 V DCRedLogic power supply (+24 V DC)
Pin 2CAN_HWhitebüS / CAN_H signal line
Pin 3SHIELDGreenCable shield connection
Pin 4CAN_LBluebüS / CAN_L signal line
Pin 5GNDBlackLogic ground (0 V DC)

Maximum supported conductor cross-section is ≤ 1.5 mm².

CANopen Bus Termination Requirement

CANopen and büS network segments require a 120 Ω terminating resistor at each end of the bus line. When the system is de-energised, the measured resistance between CAN_H and CAN_L across the network must be approximately 60 Ω.

Pneumatic Valve Power Supply (2-Pin Spring Terminal) ​

The interface plate incorporates an independent 2-pin spring-loaded terminal strip to power the 24 V DC pneumatic coils:

TerminalWire ColourAssignment
Clip 1RedAUX +24 V DC (valve coil supply)
Clip 2BlackGND (0 V DC valve return)

Control Cabinet Installation Guidelines ​

BURKERT 309093 control cabinet bottom installation geometry

When positioning the valve island inside the control cabinet, clearance dimensions must be preserved to permit replacement of individual valve slices and access to manual overrides without removing the island.

AirLINE Quick Control Cabinet Installation

Maintain the manufacturer minimum clearance distances between the valve terminal and the cabinet door/front edge. Adhering to these clearances ensures that pneumatic modules and electronic sub-assemblies can be serviced without unbolting the baseplate.

Software Configuration and Network Topology ​

BURKERT 309093 network example with Industrial Ethernet master and büS slave

Article 309093 communicates over the CANopen-based büS platform within Bürkert's Efficient Device Integration Platform (EDIP). A Type 8652 equipped with Industrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, or CC-Link IE Field Basic) can function as a fieldbus master, controlling downstream büS slave valve islands in a coordinated subsystem.

BURKERT 309093 Bürkert Communicator Type 8920 user interface

Commissioning, diagnostics, and firmware maintenance are carried out via the Bürkert Communicator software (Type 8920). Connecting a PC to the büS port requires the USB büS interface set (article no. 772426 or 772551). The software provides:

  • Graphical parameter setting and live diagnosis of all valve slots.
  • Mapping of cyclic process values and acyclic status words.
  • Backup and restoration of island device configuration files.
  • Firmware upgrades across all connected EDIP sub-modules.

Hazardous Area Approvals and Operating Conditions ​

When ordered with applicable explosion protection configurations, Type 8652 valve islands comply with international standards for Zone 2/22 and Division 2 environments:

Certification AgencyMarking CodeStandard / Certificate
ATEXII 3G Ex ec IIC Gc
II 3D Ex tc IIIC Dc
BVS 20 ATEX E 031 U
IECExEx ec IIC Gc
Ex tc IIIC Dc
IECEx BVS 20.0024 U
UL Listed (USA / Canada)Industrial Control EquipmentUL 61010-1, CAN/CSA-C22.2 No. 61010-1
cURus HazLoc (USA / Canada)Class I, Zone 2, AEx ec IIC Gc / Ex ec IIC Gc U
Class II, Zone 22, AEx tc IIIC Dc / Ex tc IIIC Dc U
Class I, Div 2, Grp A, B, C, D
Class II, III, Div 2, Grp F, G
ANSI/ISA 12.12.01, CSA C22.2 No. 213
CCC (China)Ex ec IIC Gc / Ex tc IIIC DcGB/T 3836.2021 series (SITIIAS)

Hazardous Location Electrical and Hot Swap Restrictions

For Zone 2 / Zone 22 installations, the valve terminal must be installed inside an enclosure providing a minimum ingress protection of IP54 (for Category 3G gas atmospheres) or IP6X (for Category 3D dust atmospheres). Transient overvoltage protection must prevent voltage spikes exceeding 140% of the nominal peak supply. Terminals and push-in plugs must not be connected or disconnected while energised in the presence of an explosive atmosphere.

Spare Parts and Accessories Ordering Data ​

Replacement Pilot Valves (Type 6534) ​

Circuit FunctionWidthFlow Rate QNnPressure RangeOpening TimeClosing TimeVoltageArticle No. (incl. screws)
CF-C (2x 3/2 NC)11 mm270 l/minVac...10 bar15 ms15 ms24 V DC301374 (REF 296031)
CF-H (5/2 monostable)11 mm290 l/minVac...10 bar20 ms25 ms24 V DC301376 (REF 296033)
CF-D (2x 3/2 NO)11 mm310 l/minVac...10 bar15 ms15 ms24 V DC301375 (REF 296032)
CF-Z (5/2 bistable)11 mm290 l/minVac...10 bar20 ms25 ms24 V DC301377 (REF 296034)
CF-L (5/3 closed)11 mm275 l/minVac...10 bar15 ms15 ms24 V DC301380 (REF 296036)
CF-M (5/3 ventilated)11 mm300 l/minVac...10 bar20 ms20 ms24 V DC301379 (REF 296035)
CF-N (5/3 exhausted)11 mm300 l/minVac...10 bar20 ms20 ms24 V DC301381 (REF 296039)
Dummy valve plate11 mm—————335779 (REF 327614)

AirLINE Quick 12-Slot Accessories ​

Accessory DescriptionQuantityArticle No.
Retaining plate for control cabinet exterior (12-slot, without intermediate supply)160005567
Height adapter plate (12-slot, without intermediate supply)1754961
Blind plate for cabinet floor cutout (12-slot)1754966
Screw set M5 x 10 A2 DIN 6912 (fastening island to cabinet base)10308661
5-pin spring-loaded terminal strip (büS / communication power)1920180
2-pin spring-loaded terminal strip (pneumatic valve power)1920442
USB büS interface set 1 (Type 8923) for Bürkert Communicator1772426
Terminating resistor büS / CANopen (direct plug-in)1303833