Skip to content
Direct-actingProportionalPWM Control

BURKERT 321213 Direct-Acting 2-Way Proportional Valve, Type 2873, Brass, G 1/8

Burkert Type 2873 (Model 321213) direct-acting 2-way proportional valve. Features a 2.0mm orifice, brass body, FKM seal, and 12V DC operation for demanding control loops.

BURKERT 321213 Direct-Acting 2-Way Proportional Valve, Type 2873, Brass, G 1/8

Burkert Type 2873 (Model 321213) is a direct-acting 2-way standard solenoid proportional control valve used as the regulating unit in control loops. Due to an elastomeric seat seal, the valve closes tight (integrated shut-off function), up to the DN specific nominal pressure. The plunger of the valve is assembled frictionless, which leads to an extraordinary adjustment characteristic. This valve is particularly suitable for demanding control tasks such as high control range and dry gases.

Burkert 321213 direct-acting 2-way standard solenoid control valve

Key Features

  • Excellent range
  • Very good response
  • Compact valve design
  • Orifice sizes 0.8 ... 6 mm
  • Optional: Explosion-protected coil

General Technical Data

Product propertiesDescription
Material
SealFKM, EPDM
BodyBrass, stainless steel
Circuit functionA (2/2-way solenoid proportional control valve, Direct-acting, Normally closed)
Performance data
Hysteresis< 5 %
Repeat accuracy< 0.5 % FS
Response sensitivity< 0.25 % FS
Setting range1:200
Actuating time (10...90 %)< 20 ms
Pressure range0...16 bar
Duty cycle100 % continuous operation
Electrical data
Operating voltage24 V DC (at 5 W and 24 V coil) (12 V on request)
Power consumptionMax. 9 W
Maximum coil current420 mA (at 9 W and 24 V coil)
PWM frequency1200 Hz
Medium data
Operating mediumNeutral gases, liquids on request
Medium temperature-10 °C...+ 90 °C (with FKM) / - 30 °C...+ 90 °C (with EPDM)
ViscosityMax. 21 mm²/s (21 cSt)

Note on Performance Data

Characteristic data of control behaviour depends on process conditions. Pressure data: overpressure to atmospheric pressure, depending on nominal diameter, tightness seal or nominal pressure.

Approvals and Conformities

Depending on the specific configuration, the Type 2873 series can be supplied with the following approvals:

  • Explosion protection (Optional): ATEX (II 2 G Ex mb IIC T4...T5 Gb, II 2 D Ex mb IIIC T130 °C Db) and IECEx (Ex mb IIC T4...T5 Gb, Ex mb IIIC T130 °C Db).
  • North America: Optional UL Recognized for the USA (UL 429).
  • Foods and beverages/Hygiene: USP, FDA (Code of Federal Regulations), and EC Regulation 1935/2004.

Performance Specifications

Flow Characteristic

Pressure drop$K_v$ value for liquids [m³/h]$K_v$ value for gases [m³/h]
Sub-critical $p_2 > \frac{p_1}{2}$$= Q \sqrt{\frac{\rho}{1000\Delta p}}$$= \frac{Q_N}{514}\sqrt{\frac{T_1\rho_N}{p_2\Delta p}}$
Supercritical $p_2 < \frac{p_1}{2}$$= Q \sqrt{\frac{\rho}{1000\Delta p}}$$= \frac{Q_N}{257p_1}\sqrt{T_1\rho_N}$

Exemplary Characteristic Curve

Important Sizing Note

The dimensioning of the nominal diameter is very important for proportional valves to function properly within the application. The nominal diameter must be selected so that, on the one hand, the desired flow range is achieved and, on the other hand, when the valve is fully open, a sufficient portion of the total pressure drop occurs across the valve.

Reference value: $\Delta p_{valve} > 25%$ of the total pressure drop. Otherwise, an ideal, linear valve characteristic is deformed into a curved system characteristic. If the differential pressure exceeds half the value of the nominal pressure, discontinuities may occur.

Burkert 321213 exemplary characteristic curve of a proportional valve

Product Operation

Valve control takes place through a PWM signal (pulse-width modulation). The duty cycle of the PWM signal determines the coil current and hence the position of the plunger.

The Bürkert control electronics Type 8605 converts an analogue signal to a reference value corresponding to the valve type PWM signal and provides additional functions such as temperature compensation (coil heating), ramp function and the adjustment of minimum and maximum duty cycle/coil current for the control range.

Dimensions

Threaded Version

Burkert 321213 threaded version dimensions

Port connectionAB
G 1/412-
G 1/88-
NPT 1/410-
NPT 1/87-

(Dimensions in mm)

Optional: Explosion-Protected Coil (Type 06xx)

For applications requiring explosion protection, the Type 2873 can be equipped with the Type 06xx solenoid coil (ATEX/IECEx approved).

Burkert 321213 type label for explosion-risk areas

Risk of Explosion

Following assembly, the solenoid coil is part of a closed system. If used in the potentially explosive area, there is a risk of explosion if the system is opened during operation. Do not remove or open the system during operation.

Electrostatic Discharge

In the event of a sudden discharge from electrostatically charged devices or individuals, there is a risk of an explosion in the explosion-risk area. Clean the device surface by gently wiping it with a damp or antistatic cloth only.

Electrical Data (Type 06xx):

  • Nominal voltage: 24...240 V AC/DC
  • Temperature class: T4 (064x) / T5 (065x)
  • Ambient temperature (Individual assembly): -40...+60 °C (T4) / -40...+50 °C (T5)
  • Electrical connection: Electron beam cross-linked polyolefin copolymer cable, halogen-free.