Skip to content
8 Valve SlotsPROFIBUS DPV116 Digital InputsStainless Steel AirLINE Quick5/2-Way Monostable (CF-H)IP20 / IP65 Cabinet

BURKERT 322949 Type 8652 AirLINE 8-Bank Valve Island with PROFIBUS DPV1 and Stainless Steel AirLINE Quick

BURKERT 322949 Type 8652 AirLINE 8-slot pneumatic valve island with stainless steel AirLINE Quick plate, 8 monostable 5/2-way valves, 16 digital inputs, and PROFIBUS DPV1 fieldbus communication.

BURKERT 322949 Type 8652 AirLINE 8-Bank Valve Island with PROFIBUS DPV1 and Stainless Steel AirLINE Quick

BURKERT 322949 (Type 8652 AirLINE) is a preconfigured 8-station pneumatic valve island engineered for process automation environments. Fitted with a stainless steel AirLINE Quick interface plate and all-stainless-steel push-in fluid connections (D10 supply and D6 working ports), this configuration integrates 8 servo-assisted monostable 5/2-way Type 6534 pneumatic valves (Circuit Function H), two electronic input modules providing 16 digital inputs, and a PROFIBUS DPV1 fieldbus communication module terminated via a 9-pin Sub-D connector. Diagnostic messages, operational channel states, and hardware faults are visualised locally on the built-in LC display in plain text and symbols, while cyclic process data and acyclic diagnostic information transmit directly to the central supervisory PLC.

BURKERT 322949 Type 8652 AirLINE valve island overview

Hardware Configuration and Device Architecture ​

Article 322949 represents an 8-bank hardware build optimised for space-constrained installation directly on the floor or wall of control cabinets. Every station accommodates an 11 mm wide Type 6534 solenoid valve module. In this standard production variant, internal auxiliary pilot air is routed directly from the main supply channel, eliminating the need for external pilot line piping when operating within standard pneumatic pressure thresholds.

Configuration ParameterSpecification / Execution
Article Number (Order Code)322949
Product Type8652 AirLINE
Number of Valve Slots8 stations (8 PCE)
Valve Sockets 1 to 85/2-way monostable CF-H (Type 6534)
Fieldbus CommunicationPROFIBUS DPV1 (Sub-D 9-pin female socket)
Digital Inputs (DI)16 channels total (Electronic module 1: Yes; Electronic module 2: Yes)
Mounting Base InterfaceAirLINE Quick in stainless steel 1.4301
Supply Port Connection (1)Push-in connector Ø 10 mm, stainless steel 1.4401
Working Port Connections (2, 4)Push-in connectors Ø 6 mm, stainless steel 1.4401
Auxiliary Pilot Air RoutingInternal pilot feed
Additional Intermediate SupplyNone (0 PCE; no intermediate supply module)
Integrated Exhaust Check ValvesNot fitted in ports 3 (R) or 5 (S)
Pneumatic HotSwap in Port 1 (P)Not fitted
Device Ingress RatingIP20 (IP65 / NEMA 4X sealed in closed cabinet with AirLINE Quick)

Technical Data and Operational Boundaries ​

Technical ParameterSource-Specified Value
Operating FluidLubricated or oil-free dry compressed air, neutral gases (ISO 8573-1:2010 Class 7.4.4, 5 µm filtration recommended)
Operating Pressure Range-1.0 bar to 10.0 bar (vacuum to 10 bar)
Pilot Supply Pressure Range3.0 bar to 10.0 bar
Nominal Flow Rate $Q_{\text{Nn}}$ (CF-H)290 l/min (measured at +20 °C, 6 bar inlet pressure, 1 bar differential pressure)
Operating ModeContinuous operation, 100% duty cycle (100% ED)
Valve Switching Time (CF-H)Opening: 20 ms; Closing: 25 ms (measured per ISO 12238)
Nominal Control Voltage24 V DC (±10% tolerance, maximum residual ripple 1 Vss)
Power Consumption per Valve0.7 W inrush (0.175 W continuous after electronic power reduction)
Current Consumption per Valve29 mA inrush (10 mA holding after electronic power reduction)
Electrical Protection ClassClass III in accordance with DIN EN 61140, VDE 0140
Ambient and Medium Temperature-10 °C to +55 °C
Permissible Storage Temperature-20 °C to +60 °C
Single Station Width11 mm
Housing and Seal MaterialsPolyamide (PA) housing; NBR and PUR sealing elements

AirLINE Quick Stainless Steel Mounting Interface ​

Article 322949 incorporates an AirLINE Quick adapter plate fabricated from 1.4301 stainless steel, fitted with 1.4401 stainless steel push-in connectors. AirLINE Quick mounts directly into a cutout on the control cabinet floor or wall, projecting the pneumatic connections directly outward into the plant environment while enclosing all electronics, display modules, and pilot solenoids within the protected cabinet interior.

BURKERT 322949 AirLINE Quick stainless steel adapter plate assembly

Advantages of the stainless steel AirLINE Quick interface include:

  • Eliminates individual bulkhead fittings and internal routing hoses inside the control cabinet.
  • Conserves interior enclosure footprint, permitting compact electrical enclosures.
  • Maintains NEMA 250 Type 4X and IP65 sealing at the enclosure boundary when correctly seated with the supplied perimeter seal.
  • Mechanical fluid connections: D10 mm supply port (1) and D6 mm working lines (ports 2 and 4).

Electrical Connections and Fieldbus Communication ​

The valve island utilizes separate electrical feeds for internal electronics/communication and pilot valve solenoid actuation to guarantee signal isolation.

BURKERT 322949 PROFIBUS DPV1 Sub-D 9-pin connector pinout

PROFIBUS DPV1 Fieldbus Interface (Sub-D 9-Pin) ​

PROFIBUS DPV1 communication links via a 9-pin D-Sub socket on the communication interface module:

Pin NumberSignal AssignmentDescription
1SHIELDINGCable shield ground connection
2M24Optional 24 V ground return
3RxD/TxD-PB-line (Receive / Transmit data positive)
4CNTR-PControl signal P (optional repeater control)
5DGNDData ground (0 V reference)
6+5 V+5 V DC termination power supply
7+24 VOptional 24 V DC auxiliary feed
8RxD/TxD-NA-line (Receive / Transmit data negative)
9CNTR-NControl signal N (optional)

Auxiliary Power Supply Connections ​

  • Logic and Display Supply (5-Pin Spring Terminal): Red: 24 V DC; White: CAN_H (internal büS connection); Green: Shield; Blue: CAN_L (internal büS connection); Black: GND (0 V DC). Cable cross-section: ≤ 1.5 mm².
  • Pneumatic Valve Solenoid Supply (2-Pin Spring Terminal): Clip 1 (Red): AUX 24 V DC; Clip 2 (Black): GND (0 V DC). Independent valve power feed allows emergency shutdown or safety disconnection without interrupting fieldbus communication or sensor diagnostics.

Digital Input Modules (16 DI) ​

Article 322949 is equipped with two 8-channel electronic input modules, yielding 16 digital inputs for limit switches, proximity sensors, or position feedback transmitters.

BURKERT 322949 digital input terminal configuration for 8DI electronic modules

Electronic Module ParameterCharacteristic Value
Supported Sensor Types2-wire sensors, 3-wire sensors, mechanical potential-free switches
Module Supply Voltage24 V DC supplied via electronic module (max. 30 mA per DI channel)
Input Switching Thresholds$V_{\text{OFF}} = 0\text{ to }5\text{ V DC}$; $V_{\text{ON}} = 10\text{ to }30\text{ V DC}$
Input Current at $V_{\text{ON}}$Max. 5.7 mA per channel (typical at 24 V DC)
Input Impedance> 4 kΩ
Galvanic IsolationNo (all DI channels share a common reference potential)
Diagnostic CapabilitiesWire-break detection (2-wire sensors); Short-circuit detection (3-wire sensors)
Maximum Cable Length< 30 m
Permissible Conductor Cross-Section0.14 mm² to 1.5 mm² (AWG 28 to AWG 16)

Sensor diagnostic operational matrix:

Sensor State / Fault3-Wire Sensor2-Wire SensorMechanical Limit Switch
Sensor ActuatedDetected (X)Detected (X)Detected (X)
Sensor Not ActuatedDetected (X)Detected (X)Detected (X)
Short CircuitDetected (X)Not detectable (—)Not detectable (—)
Wire BreakNot detectable (—)Detected (X)Not detectable (—)

Pneumatic Circuit Function H (Type 6534 Valves) ​

All 8 valve positions on 322949 are occupied by Type 6534 5/2-way monostable solenoid valves operating under Circuit Function H (CF-H).

BURKERT 322949 Circuit Function H 5/2-way monostable pneumatic circuit diagram

  • Operating Principle: Servo-assisted spool valve with manual override. Pressure is continuously applied via port 1. In the de-energized normal position, port 1 connects to working port 2 while working port 4 vents through exhaust port 5. When energized, the valve shifts, connecting port 1 to working port 4 while working port 2 exhausts through port 3.
  • Orifice: 4 mm.
  • Switching Characteristics: Nominal opening response time is 20 ms; closing response time is 25 ms per ISO 12238.

Dimensions and Enclosure Installation Guidelines ​

BURKERT 322949 8-fold valve island dimensional drawing and mounting pitch

BURKERT 322949 control cabinet floor mounting position and minimum clearances

8-Fold Dimensional Coordinates ​

Per the manufacturer dimensional drawing for 4-, 8-, and 12-slot variants:

  • Dimension A: 35 mm
  • Dimension B: 111 mm
  • Fastening Pattern C: 8 × M5 mounting threads
  • Pitch Index m: 7
  • Module Index n: 2
  • Station Pitch: 11 mm per valve slot

Mounting is supported on standard DIN rail (EN 50022 35 × 7.5 mm or 35 × 15 mm) or directly to the cabinet enclosure wall/floor via AirLINE Quick.

Hazardous Location Approvals and Safety Instructions ​

Type 8652 valve islands hold certifications for explosive atmospheres when ordered with designated Ex approval codes (such as PX68 or PU17):

  • ATEX: BVS 20 ATEX E 031 U — II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc
  • IECEx: IECEx BVS 20.0024 U — Ex ec IIC Gc / Ex tc IIIC Dc
  • cURus HazLoc (North America): Class I, Zone 2, AEx ec IIC Gc / Ex ec IIC Gc U; Class II, Zone 22, AEx tc IIIC Dc / Ex tc IIIC Dc U; Class I, Division 2, Groups A, B, C, D; Class II/III, Division 2, Groups F, G
  • China Compulsory Certification: CCC Ex certified under GB/T 3836
  • UL Listed: UL 61010-1 and CAN/CSA-C22.2 No. 61010-1

Hazardous Atmosphere Safety Precautions

Do not connect or disconnect electrical plug connectors, terminals, or wiring when energized unless the atmosphere is known to be non-explosive. When installing in Zone 2 / 22 environments, Type 8652 must be installed inside an enclosure providing at least IP54 protection for gas (3G/Gc) and IP6X for dust (3D/Dc) in accordance with EN/IEC 60079-0, EN/IEC 60079-7, and EN/IEC 60079-31. Transient protection must limit peak overvoltages to a maximum of 140% of the nominal peak supply voltage.

Temperature Classes and Enclosure Thermal Limits

At an internal control cabinet ambient temperature of up to +55 °C, the assembly does not exceed the limits of temperature class T4. When using the AirLINE Quick interface version, the maximum allowable surface temperature on the outside of the control cabinet is +80 °C.

Dedicated Replacement Parts and Accessories ​

Item DescriptionOrdering / Article Number
Replacement Valve Type 6534 CF-H (5/2-way monostable, 24 V DC, incl. screws)301376 (Spare Kit REF_296033)
Replacement Valve Type 6534 Blanking Plate (Dummy Valve)335779 (REF_327614)
Valve Display / Electronic Module with Digital Inputs (8DI)384872
Valve Display / Electronic Module without Digital Inputs384873
5-Pin Spring-Loaded Terminal Block (Logic & Display Power)920180
2-Pin Spring-Loaded Terminal Block (Pneumatic Valve Power)920442
AirLINE Quick Height Adapter for 8-Fold Base (without intermediate feed)754960
AirLINE Quick Retaining Plate for 8-Fold Base (cabinet exterior mounting)60005566
AirLINE Quick Blind Plate for 8-Fold Base754965
Stainless Steel Fastening Screw Set (10 pcs M5 × 10 A2 DIN 6912)308661
Bürkert Communicator Software Type 8920Type 8920
USB büS Interface Set 1 (Type 8923 with cables, terminating resistor, stick)772426