Burkert 323144 Type 2104 is an externally controlled T-diaphragm valve with a pneumatic piston actuator, EPDM diaphragm, and stainless steel body for hygienic applications.

Burkert 323144 Type 2104 is an externally controlled T-diaphragm valve consisting of a pneumatically operated piston actuator, a diaphragm, and a T-valve body. The proven and robust actuator with a stainless steel housing ensures reliable use in hygienic or aggressive ambient conditions. The flow-efficient valve bodies with minimal dead space enable high flow rates and a wide range of possible uses. The actuator features a compact, autoclavable design with gap-free seals, and allows for the integration of ELEMENT automation units in all configuration levels.

| Feature | Description |
|---|---|
| Block body material | Stainless steel block material 1.4435 (DIN EN 10088) and 316L (ASTM A479 / ASME BPE) |
| Diaphragm material | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
| Actuator material | DN 08...65: PPS; DN 65...100: Stainless steel 1.4308 |
| Standard surface quality | Internally electrically polished: Ra ≤ 0.38 μm (ASME BPE SF4 / DIN HE4) |
| Maximum pilot pressure | 10 bar (7 bar for actuator size 130, 225) |
| Operating medium | Neutral gases and liquids, highly purified, sterile, aggressive or abrasive mediums |
| Ambient temperature | -10 °C to +60 °C (autoclavable) |
| Symbol | Description |
|---|---|
| CF A | Pneumatically operated T-valve. Normally closed by spring force. |
| CF B | Pneumatically operated T-valve. Normally opened by spring force. |
| CF I | Pneumatically operated T-valve on either side. Switching position dependent on external control. |

| No. | Element | Material |
|---|---|---|
| 1 | Ground terminal | Stainless steel 1.4301/1.4305 (only for ATEX/IECEx variant) |
| 2 | Transparent cap | Polysulfone PSU |
| 3 | Pilot air ports | Push-in connector PP (standard), Thread G 1/8" stainless steel 1.4305 |
| 4 | Actuator | Polyphenylene sulphide PPS |
| 5 | Cover | Stainless steel 1.4561 (316Ti) |
| 6 | Piston seal | FKM |
| 7 | Diaphragm | EPDM, PTFE/EPDM, advanced PTFE/EPDM, laminate of GYLON® and EPDM |
Damage to the diaphragm or the actuator
The diaphragm and actuator can be damaged when welding the valve body into the pipeline. In the case of devices with a welded connection, remove the actuator and diaphragm from the valve body before installation.
Removing the actuator from the valve body:
Installing the actuator on the valve body (CF A):
Explosion hazard due to electrostatic charging!
If a statically charged device or person discharges suddenly, there is an explosion hazard in the potentially explosive area.