Up to DN 13Vibration-proofKick and Drop optionExplosion proof variants

BURKERT 323671 6027 Direct-acting 2/2-way Plunger Solenoid Valve

Burkert Type 6027 direct-acting 2/2-way plunger solenoid valve. Features a vibration-proof bolted coil system, sizes up to DN 13, and optional Kick and Drop technology.

BURKERT 323671 6027 Direct-acting 2/2-way Plunger Solenoid Valve

BURKERT 6027 is a direct-acting plunger valve. The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. The coils are moulded with chemically resistant epoxy. An optional sliding ring bearing increases the service life with dry gases. Special seal technology is used for high-pressure applications. To reduce power consumption in operation, coils with Kick and Drop electronics assembly (double coil technology) are available. In combination with a plug in accordance with DIN EN 175301-803 Form A, the valves satisfy protection class IP65. NEMA 4X is available on request.

General Technical Data

Product properties
DimensionsSee Dimensions section
Material
SealFKM, EPDM, NBR, PTFE and PEEK
BodyBrass, stainless steel 1.4404/316L
CoilEpoxy
OrificeDN 1.0...DN 13.0
Circuit functionA and B
Thermal insulation classEpoxy coil class H
Duty cycle100% continuous operation
Switching time ACOpening: 10...30 ms, Closing: 50...80 ms
Switching time DCOpening: 20...30 ms, Closing: 50...80 ms
Operating voltage24 V DC, 24 V 50 Hz, 24 V 60 Hz, 110 V 50 Hz, 120 V 60 Hz, 230 V 50 Hz, 240 V 60 Hz
Voltage tolerance±10%

Medium Data

Standard Operating Medium: Vacuum, neutral gases and liquids (e.g. compressed air, water, hydraulic oil, petrol, DVGW 1-3 gas family) and slightly aggressive medium, hot liquids and steam. Oil burner variant (PF15): Heating oil (EL, L, M, S) acc. to DIN 51603 part 1...6, shipping fuels acc. to ISO 8217. Only with stainless steel body: Fatty acid methyl ester (FAME) acc. to DIN EN 14213, rapeseed oil acc. to DIN V 51605.

Circuit Functions

BURKERT 323671 BURKERT 6027 circuit functions A and B

  • Circuit function A (CF A): 2/2-way solenoid valve, Direct-acting, Normally closed
  • Circuit function B (CF B): 2/2-way solenoid valve, Direct-acting, Normally open

Approvals and Conformities

  • Explosion protection: Optional explosion protection according to category 2 (zone 1/21). ATEX and IECEx certifications available for coils with cable outlet or terminal box.
  • North America (USA/Canada): Optional UL Listed (UL 429, CAN/CSA-C22.2 No. 139-19) and UL Hazardous Locations.
  • Drinking water: Suitable for use in drinking water applications. Materials comply with UBA assessment principles.
  • Foods and beverages/Hygiene: FDA Code of Federal Regulations and USP biocompatibility options available.
  • Oxygen: Optional suitability for gaseous oxygen.
  • Fire protection on railway vehicles: Complies with DIN EN 45545 applicable parts 2 and 5.
  • Safety shut-off valves: According to DIN EN ISO 23553-1 (variable code PF15).
  • Fuel gases: Complies with Regulation (EU) 2016/426 and DVGW DIN EN 161.

Materials

Standard Variant (Elastomer seal up to 30 bar)

BURKERT 323671 BURKERT 6027 standard variant elastomer seal cross section

No.ElementMaterial
1NutDIN 176 thick-film passivated or stainless steel
2CoilEpoxy
3StopperStainless steel 1.4113/434
4Shading ringCopper (brass body), Silver (stainless steel body)
5SpringStainless steel 1.4310/301
6PlungerStainless steel 1.4113/434
7Guide tubeStainless steel 1.4303/305/308
8NippleBrass, stainless steel 1.4305/303
9SealFKM, PEEK (EPDM on request)
10Seat sealFKM (EPDM on request)
11HousingBrass, stainless steel 1.4404/316L (CF3M)

Dimensions

Standard Variant (Threaded)

BURKERT 323671 BURKERT 6027 standard variant dimensions drawing

Note: Dimensions in mm.

Safety Instructions

Danger due to high pressure and electrical voltage

  • Before loosening lines and valves, turn off the pressure and vent the lines.
  • Before working on or inside the device or the system, switch off the power supply and secure against reactivation.
  • Observe the applicable accident prevention and safety regulations for electrical devices.

Risk of burns and escaping medium

  • Do not touch the device with your bare hands during or immediately after operation due to hot surfaces.
  • Make sure seals are properly seated to prevent escaping medium.
  • Carefully screw the coil and cable plug together.

Installation Note

Installation position is any, preferably with the actuator on top. Before installation, check pipelines for soiling and clean if necessary. Install a dirt trap at the valve inlet (0.2...0.4 mm).