Skip to content
Type 0330Circuit Function CDN 5 mmG 1/4110 V ACIP65

BURKERT 327882 (Type 0330) 3/2-Way Direct-Acting Solenoid Valve, Brass G 1/4

Burkert 327882 (Type 0330) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve featuring circuit function C, brass body, G 1/4 ports, NBR seal, and 110 V 50/60 Hz coil.

BURKERT 327882 (Type 0330) 3/2-Way Direct-Acting Solenoid Valve, Brass G 1/4

BURKERT 327882 (Type 0330) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve configured in circuit function C (normally closed). Built with a brass body, G 1/4 female threaded ports, and an NBR sealing diaphragm, the valve operates across a process pressure range of 0.00 to 2.50 bar with a nominal orifice of 5.0 mm (3/16 inch). The fluidic chamber is isolated from the electromagnetic actuator by a flexible separating membrane, preventing process fluids from contacting internal metallic solenoid components.

The valve is driven by a class H epoxy-encapsulated solenoid coil engineered for 110 V AC (50/60 Hz) operation and includes a DIN EN 175301-803 Form A cable plug. A built-in manual override enables mechanical commissioning and functional checks without electrical excitation. With a 46 mm installation length and 100% continuous duty rating, article 327882 provides fast switching speeds (8 to 15 ms opening and closing) for neutral media including compressed air, technical water, hydraulic oil, and town gas up to a kinematic viscosity of 37 mm²/s.

BURKERT 327882 Type 0330 direct-acting pivoted armature solenoid valve

Technical Parameters ​

ParameterSpecification
Article Number327882
Valve Family Type0330
Circuit FunctionC (3/2-way, normally closed, inlet P/NC, outlet A/OUT, exhaust R/NO)
Nominal Diameter (DN)5.0 mm (3/16")
Port ConnectionG 1/4 internal thread
Construction Length46 mm
Valve Body MaterialBrass
Valve Seat MaterialBrass
Sealing MaterialNBR (70 Shore A)
Fluidic Pressure Range0.00 to 2.50 bar (gauge pressure); vacuum down to -0.98 bar
Flow Factor Kv (Water)0.29 m³/h
Nominal Flow QNn (Air)310 l/min
Rated Voltage110 V AC (50/60 Hz, tolerance ±10%)
AC Power ConsumptionInrush: 30 VA, Hold: 15 VA (8 W active hold power)
Switching TimesOpening: 8 to 15 ms, Closing: 8 to 15 ms
Duty Cycle100% ED continuous operation
Coil InsulationEpoxy, class H
Electrical ConnectionPlug pattern Form A according to DIN EN 175301-803
Enclosure RatingIP65 (with mating cable plug installed)
Medium Temperature0 °C to +80 °C
Ambient TemperatureMax. +55 °C
Maximum Viscosity37 mm²/s
WeightApprox. 0.45 kg (metal body)
Manual OverrideMechanical lever, lockable

Circuit Function and Port Allocation ​

Article 327882 operates under Circuit Function C (CF C), defined as a direct-acting 3/2-way solenoid valve that is normally closed in its de-energized rest state. In this position, inlet port 1 (P/NC) is closed, while working outlet port 2 (A/OUT) is connected to exhaust port 3 (R/NO). Upon electrical energization, the pivoted armature shifts to connect port 1 (P) directly to port 2 (A), sealing off exhaust port 3 (R).

Circuit FunctionDescriptionPort 1Port 2Port 3
CF C3/2-way direct-acting, normally closedP (Pressure inlet)A (Working outlet)R (Exhaust / return)

BURKERT 327882 Type 0330 3-way fluidic port connection assignment

Materials of Construction ​

The wetted section and actuation components utilize materials selected for mechanical endurance and chemical compatibility with neutral gases and fluids:

BURKERT 327882 Type 0330 material cross-section

Position No.ElementMaterial in Article 327882General Family Options
1Coil encapsulationEpoxy (Class H)Epoxy
2DiaphragmNBRNBR, EPDM, FKM, FFKM
3O-ringNBRNBR, EPDM, FKM, FFKM
4SeatBrassBrass, Stainless steel (1.4401), PP, PEEK
5Valve bodyBrassBrass, Stainless steel (1.4401), PP, PEEK

Dimensions and Mechanical Mounting ​

Burkert 327882 features standard G 1/4 parallel pipe threads on all three fluid ports. The body underside provides mounting provisions for rigid machine and bracket installation.

BURKERT 327882 Type 0330 metal body dimensions and port layout

  • Port Threads: G 1/4 with thread depth L1 = 9 mm (D1 = G 1/4). The minimum thread engagement depth at the middle port is 7.5 mm.
  • Base Fastening: Four threaded M4 holes on the underside arranged in a 38 mm x 24 mm pattern (M4 x 8 mm thread depth).
  • Overall Valve Length: 46 mm across main fluid ports.
  • Actuator Orientation: The valve may be installed in any physical orientation; mounting with the solenoid actuator upright is recommended.

Installation and Manual Override Operation ​

Upstream Filtration

Install a dirt trap or inline filter with mesh size ≤ 500 µm upstream of port 1 (P) to prevent solid particulates from lodging between the seat and sealing diaphragm.

Before mounting, ensure the pipeline is thoroughly flushed and de-energized. Use PTFE sealing tape on pipe threads and support the valve body with an open-ended spanner during torque application; never apply rotational force through the solenoid coil housing.

BURKERT 327882 Type 0330 manual override actuation and locking mechanism

Article 327882 includes a mechanical manual override lever positioned on the valve body for manual commissioning, manual testing, or emergency operation:

  1. Press and hold the manual override lever downward.
  2. Turn the lever clockwise to lock the valve in its open working state.
  3. Turn the lever counter-clockwise to unlock and return control to electrical operation.

Manual Override Interlock

When the manual override is locked, the valve cannot be actuated electrically. Verify that the manual override is returned to its unlocked rest state prior to running automated sequences.

Electrical Connection ​

Electrical Safety

Disconnect all power supplies and relieve internal pipeline pressure before opening terminal connections or disassembling the unit. Always connect the protective earth (PE) terminal and verify continuity to the metallic valve body.

BURKERT 327882 Type 0330 electrical connection with Form A cable plug and seal

Electrical connection is established through an included Form A cable plug conforming to DIN EN 175301-803:

  • Connect supply line L1 and neutral N to terminals 1 and 2 of the cable plug.
  • Connect the ground lead to the protective conductor terminal (PE).
  • Position the rubber seal flat between the plug base and coil terminal face.
  • Fasten the central fixing screw with a maximum tightening torque of 1 Nm to maintain the IP65 enclosure seal.

Maintenance and Troubleshooting ​

The pivoted armature design contains no sliding metal parts exposed to the fluid, eliminating frictional wear in the media path. If operational faults occur, perform the diagnostic steps in the table below:

FaultPossible CauseCorrective Action
Valve does not switchPower supply missing or voltage deviation > ±10%Verify 110 V AC 50/60 Hz supply across terminals 1 and 2
Electrical coil interrupted or short-circuitedInspect coil winding resistance; replace defective unit
Operating pressure exceeds 2.50 barVerify supply pressure remains within 0 to 2.50 bar limit
Manual override locked in engaged positionRotate manual override counter-clockwise to release
Valve does not closeForeign particulate matter under seat diaphragmDisassemble and clean valve interior; install upstream ≤ 500 µm filter
Manual override lockedDisengage manual override lever
External leakagePort fittings insufficiently sealed or looseReseal thread connections with PTFE tape; check M4 mounting screws