Burkert 327882 (Type 0330) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve featuring circuit function C, brass body, G 1/4 ports, NBR seal, and 110 V 50/60 Hz coil.

BURKERT 327882 (Type 0330) is a direct-acting, media-separated 3/2-way pivoted armature solenoid valve configured in circuit function C (normally closed). Built with a brass body, G 1/4 female threaded ports, and an NBR sealing diaphragm, the valve operates across a process pressure range of 0.00 to 2.50 bar with a nominal orifice of 5.0 mm (3/16 inch). The fluidic chamber is isolated from the electromagnetic actuator by a flexible separating membrane, preventing process fluids from contacting internal metallic solenoid components.
The valve is driven by a class H epoxy-encapsulated solenoid coil engineered for 110 V AC (50/60 Hz) operation and includes a DIN EN 175301-803 Form A cable plug. A built-in manual override enables mechanical commissioning and functional checks without electrical excitation. With a 46 mm installation length and 100% continuous duty rating, article 327882 provides fast switching speeds (8 to 15 ms opening and closing) for neutral media including compressed air, technical water, hydraulic oil, and town gas up to a kinematic viscosity of 37 mm²/s.

| Parameter | Specification |
|---|---|
| Article Number | 327882 |
| Valve Family Type | 0330 |
| Circuit Function | C (3/2-way, normally closed, inlet P/NC, outlet A/OUT, exhaust R/NO) |
| Nominal Diameter (DN) | 5.0 mm (3/16") |
| Port Connection | G 1/4 internal thread |
| Construction Length | 46 mm |
| Valve Body Material | Brass |
| Valve Seat Material | Brass |
| Sealing Material | NBR (70 Shore A) |
| Fluidic Pressure Range | 0.00 to 2.50 bar (gauge pressure); vacuum down to -0.98 bar |
| Flow Factor Kv (Water) | 0.29 m³/h |
| Nominal Flow QNn (Air) | 310 l/min |
| Rated Voltage | 110 V AC (50/60 Hz, tolerance ±10%) |
| AC Power Consumption | Inrush: 30 VA, Hold: 15 VA (8 W active hold power) |
| Switching Times | Opening: 8 to 15 ms, Closing: 8 to 15 ms |
| Duty Cycle | 100% ED continuous operation |
| Coil Insulation | Epoxy, class H |
| Electrical Connection | Plug pattern Form A according to DIN EN 175301-803 |
| Enclosure Rating | IP65 (with mating cable plug installed) |
| Medium Temperature | 0 °C to +80 °C |
| Ambient Temperature | Max. +55 °C |
| Maximum Viscosity | 37 mm²/s |
| Weight | Approx. 0.45 kg (metal body) |
| Manual Override | Mechanical lever, lockable |
Article 327882 operates under Circuit Function C (CF C), defined as a direct-acting 3/2-way solenoid valve that is normally closed in its de-energized rest state. In this position, inlet port 1 (P/NC) is closed, while working outlet port 2 (A/OUT) is connected to exhaust port 3 (R/NO). Upon electrical energization, the pivoted armature shifts to connect port 1 (P) directly to port 2 (A), sealing off exhaust port 3 (R).
| Circuit Function | Description | Port 1 | Port 2 | Port 3 |
|---|---|---|---|---|
| CF C | 3/2-way direct-acting, normally closed | P (Pressure inlet) | A (Working outlet) | R (Exhaust / return) |

The wetted section and actuation components utilize materials selected for mechanical endurance and chemical compatibility with neutral gases and fluids:

| Position No. | Element | Material in Article 327882 | General Family Options |
|---|---|---|---|
| 1 | Coil encapsulation | Epoxy (Class H) | Epoxy |
| 2 | Diaphragm | NBR | NBR, EPDM, FKM, FFKM |
| 3 | O-ring | NBR | NBR, EPDM, FKM, FFKM |
| 4 | Seat | Brass | Brass, Stainless steel (1.4401), PP, PEEK |
| 5 | Valve body | Brass | Brass, Stainless steel (1.4401), PP, PEEK |
Burkert 327882 features standard G 1/4 parallel pipe threads on all three fluid ports. The body underside provides mounting provisions for rigid machine and bracket installation.

Upstream Filtration
Install a dirt trap or inline filter with mesh size ≤ 500 µm upstream of port 1 (P) to prevent solid particulates from lodging between the seat and sealing diaphragm.
Before mounting, ensure the pipeline is thoroughly flushed and de-energized. Use PTFE sealing tape on pipe threads and support the valve body with an open-ended spanner during torque application; never apply rotational force through the solenoid coil housing.

Article 327882 includes a mechanical manual override lever positioned on the valve body for manual commissioning, manual testing, or emergency operation:
Manual Override Interlock
When the manual override is locked, the valve cannot be actuated electrically. Verify that the manual override is returned to its unlocked rest state prior to running automated sequences.
Electrical Safety
Disconnect all power supplies and relieve internal pipeline pressure before opening terminal connections or disassembling the unit. Always connect the protective earth (PE) terminal and verify continuity to the metallic valve body.

Electrical connection is established through an included Form A cable plug conforming to DIN EN 175301-803:
The pivoted armature design contains no sliding metal parts exposed to the fluid, eliminating frictional wear in the media path. If operational faults occur, perform the diagnostic steps in the table below:
| Fault | Possible Cause | Corrective Action |
|---|---|---|
| Valve does not switch | Power supply missing or voltage deviation > ±10% | Verify 110 V AC 50/60 Hz supply across terminals 1 and 2 |
| Electrical coil interrupted or short-circuited | Inspect coil winding resistance; replace defective unit | |
| Operating pressure exceeds 2.50 bar | Verify supply pressure remains within 0 to 2.50 bar limit | |
| Manual override locked in engaged position | Rotate manual override counter-clockwise to release | |
| Valve does not close | Foreign particulate matter under seat diaphragm | Disassemble and clean valve interior; install upstream ≤ 500 µm filter |
| Manual override locked | Disengage manual override lever | |
| External leakage | Port fittings insufficiently sealed or loose | Reseal thread connections with PTFE tape; check M4 mounting screws |