Burkert 353673 (Type 0330) direct-acting 2/2-way normally closed solenoid valve. Features brass body, FKM seal, 24V, ATEX/IECEx explosion-proof, and G1/4 port.

Burkert 353673 (Type 0330) is a direct-acting, media-separated pivoted armature solenoid valve. It features maintenance-free pivoted armature technology and a vibration-proof, block screwed coil system. The 353673 variant is specifically configured as a 2/2-way normally closed valve with a brass body, FKM seals, and a 3000 mm moulded cable. The solenoid coils are moulded with a chemically resistant epoxy, and the coil system is separated from the medium by a diaphragm, making it suitable for critical media. This specific model is explosion-proof with ATEX and IECEx certifications.
| Property | Value |
|---|---|
| Orifice | DN 4.00 mm |
| Circuit function | A (2/2-way, normally closed) |
| Body material | Brass |
| Seal material | FKM (Fluor rubber) |
| Weight (Explosion-proof) | Metal body: 0.75 kg |
| Thermal insulation class | Epoxy coil class H |
| Duty cycle | 100% continuous operation |
| Voltage | 24 V (AC/DC) |
| Voltage tolerance | ±10% |
| Medium temperature | 0 °C to +90 °C |
| Ambient temperature | Max. +55 °C |
| Viscosity | Max. 37 mm²/s |
| Port connection | G 1/4 |
| Electrical connection | Moulded wire cable (3000 mm) |
| Degree of protection | IP65 |
The 353673 model operates with Circuit Function A (CF A).

This variant features explosion protection according to category 2 (zone 1/21). The Ex marking of the components for coils with a cable outlet is:
Safety Instruction
Explosion hazard. The solenoid coil forms a closed system after installation. When used in explosion-risk areas, there is a risk of explosion if the system is opened in the operating state. Do not remove or open the system during operation.
| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Diaphragm | FKM |
| 3 | O-ring | FKM |
| 4 | Seat | Brass |
| 5 | Valve body | Brass |

| D1 | L1 | D2 | L2 |
|---|---|---|---|
| G 1/8 | 9 | - | - |
| G 1/4 | 9 | NPT 1/4 | 7.5 |
Note
Dimensions in mm. For metal bodies, the minimum thread length at the middle connection is 7.5 mm. The device can be attached via the existing holes on the bottom side (hole pattern 38x24) using M4 screws.

For the metal body, Circuit Function A, DN 4.0 mm:
| Circuit function | DN | Kv value water [m³/h] | Pressure range Standard [bar] | Pressure range Vacuum [bar] |
|---|---|---|---|---|
| A | 4.0 | 0.23 | 0...5 | -0.98...3 |
Note: Devices with FKM diaphragms are reduced to a maximum pressure of 12 bar. Pressure data indicates overpressure to atmospheric pressure.
Explore similar products in our catalog