Skip to content
AirLINE SPWAGO I/O System 750IP2016.5 mm

BURKERT 357411 8644 AirLINE SP Electropneumatic Automation System, 16.5 mm

The BURKERT 8644 AirLINE SP electropneumatic automation system integrates electric and pneumatic building blocks with direct WAGO I/O System 750 connection.

BURKERT 357411 8644 AirLINE SP Electropneumatic Automation System, 16.5 mm

The BURKERT 8644 AirLINE SP electropneumatic automation system represents a universal interface between process and system control. It integrates electric and pneumatic building blocks into an assembly, enabling a modular and flexible structure of fieldbus modules, pilot valves, and I/O modules thanks to simple locking technology on the standard rail.

BURKERT 357411 BURKERT 8644 type description 1BURKERT 357411 BURKERT 8644 type description 2BURKERT 357411 BURKERT 8644 type description 3

The system features direct connection to the WAGO I/O System 750, an innovative fieldbus interface, compact design, high flexibility, and high flow rates.

General Technical Data

Product propertiesType 0460, Type 6524, Type 6525Type 0461, Type 6526, Type 6527
Material
BodyPA (polyamide), aluminium (Type 0460)PA (polyamide), aluminium (Type 0461)
SealFKM, NBR and PURNBR
Maximum installation width
Width per station11 mm16.5 mm
Manual overrideStandardStandard
Number of valve slotsFor single valves: max. 64
For impulse and double valves: max. 32
Max. 32
When using Type 0461: 24
Maximum number of valve functionsMax. 64Max. 32
Pneumatic intermediate supplyNecessary for single valves after 24 valve functions. Necessary after 16 valve functions for double valvesNecessary after 16 valve functions
Performance data
Pressure dataOverpressure to atmospheric pressureOverpressure to atmospheric pressure
Pressure rangeVac...10 barVac...10 bar
External supply air>2.5 bar (Type 0460: not possible)>2.5 bar (Type 0461: not possible)
Flow rate $Q_{\text{Nn}}$ value air200...300 l/min500...700 l/min
Nominal operating modeContinuous operation (100 % duty cycle)Continuous operation (100 % duty cycle)
Electrical data
Operating voltage24 V DC24 V DC
Voltage tolerance+20%/-15% (when using Type 0460: ±10%)+20%/-15% (when using Type 0461: ±10%)
Residual ripple (at DC)1 Vss1 Vss
Nominal power of each valveFor single valves: 0.8 W
For impulse and double valves: 2× 0.8 W with power reduction
2 W, 1 W
Nominal current of each valve43 mA (28 mA holding current after 120 ms)
41 mA (when using Type 0460)
85 mA (52 mA holding current after 120 ms)
41 mA (when using Type 0461)
Protection classIII according to VDE 106, IEC 60536III according to VDE 106, IEC 60536
Medium data
Operating mediumOil-free or lubricated compressed dry air (5 μm filter recommended)Oil-free or lubricated compressed dry air (5 μm filter recommended)
Compressed air qualityISO 8573 - 1: 2010, Class 7.4.4ISO 8573 - 1: 2010, Class 7.4.4
Approvals and conformities
Degree of protectionIP20
IP65 in closed control cabinets
IP20
IP65 in closed control cabinets
Product connections
Working connectionD 4, D 6, D 1/4, D 8, NPT 1/8, G 1/8D 8, NPT 3/8, G 1/8
Air supply connectionG 1/4, NPT 1/4, D 10, G 3/8, NPT 3/8G 3/8, NPT 3/8
Communication moduleWAGO I/O System 750WAGO I/O System 750
Communication interfacePROFIBUS DP, INTERBUS, DeviceNet, CANopen, Ethernet. Others on requestPROFIBUS DP, INTERBUS, DeviceNet, CANopen, Ethernet. Others on request
Environment and installation
Installation positionAs required, preferably with actuator uprightAs required, preferably with actuator upright
Storage temperature-20 °C...+60 °C-20 °C...+60 °C
Ambient temperature0 °C...+55 °C (when using Type 0460: 0 °C...+50 °C)0 °C...+55 °C (when using Type 0461: 0 °C...+50 °C)

Circuit Functions

SymbolDescription
BURKERT 357411 BURKERT 8644 circuit function CCircuit function C (CF C)
3/2-way solenoid valve
Servo-controlled, with manual override
Normally closed
BURKERT 357411 BURKERT 8644 circuit function C 2x 1 BURKERT 357411 BURKERT 8644 circuit function C 2x 2Circuit function C (CF C)
2 × 3/2-way solenoid valve
Servo-controlled, with manual override
Normally closed
BURKERT 357411 BURKERT 8644 circuit function DCircuit function D (CF D)
3/2-way solenoid valve
Servo-controlled, with manual override
Normally open
BURKERT 357411 BURKERT 8644 circuit function HCircuit function H (CF H)
5/2-way solenoid valve
Servo-controlled, with manual override
Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.
BURKERT 357411 BURKERT 8644 circuit function LCircuit function L (CF L)
5/3-way solenoid valve
With manual override
In middle position all ports locked
BURKERT 357411 BURKERT 8644 circuit function NCircuit function N (CF N)
5/3-way solenoid valve
With manual override
In middle position ports 2 and 4 exhausted
BURKERT 357411 BURKERT 8644 circuit function ZCircuit function Z (CF Z)
5/2-way solenoid valve
Impulse variant with 2 coils and manual override
Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.

Approvals and Conformities

  • Explosion protection: As a category 3 device suitable for zone 2 (optional). ATEX: PTB 15 ATEX 2001 XII 3G Ex ec IIC T4 Gc. IECEx: IECEx PTB 16.0014 X Ex ec IIC T4 Gc.
  • North America (USA/Canada): Optional: UL Listed for the USA and Canada according to UL 61010-1 and CAN/CSA-C22.2 No. 61010-1.

Dimensions

Type 8644 with valves Type 6524/6525 (11 mm width per station)

BURKERT 357411 BURKERT 8644 dimensions 11mm

Type 8644 with single valve Type 6526/6527 (16.5 mm width per station)

BURKERT 357411 BURKERT 8644 dimensions 16.5mm 1BURKERT 357411 BURKERT 8644 dimensions 16.5mm 2

Example Configuration