BURKERT 361031 Type 2104 pneumatic diaphragm T-valve. Features a stainless steel body, PTFE/EPDM diaphragm, DN65 weld end, and 0-10 bar operating pressure for hygienic applications.

BURKERT 361031 Type 2104 is an externally controlled diaphragm T-valve consisting of a pneumatically operated piston actuator, a diaphragm, and a T-valve body. The proven and robust actuator with a stainless steel or PPS housing ensures reliable use in hygienic or aggressive ambient conditions. The flow-efficient valve bodies with minimal dead space enable high flow rates and a wide range of possible uses in the food, beverage, biotechnology, and pharmaceutical industries.

The actuator features a compact, autoclavable design with gap-free seals. The integration of automation units Type ELEMENT is possible in all configuration levels, and a fieldbus interface can also be integrated. The valve offers degrees of protection IP65/67 and NEMA Type 4X, displaying high chemical resistance.

| Product Properties | Details |
|---|---|
| Block body (VH/VI) | Stainless steel block material 1.4435 according to DIN EN 10088 and 316L according to ASTM A479 / A479M / ASME BPE |
| Diaphragm | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
| Actuator | DN 08...65, PPS; DN 65...100, stainless steel 1.4308 |
| Actuator casing | DN 08...65, stainless steel 1.4561 (316Ti); DN 65...100, stainless steel 1.4308 |
| Standard surface quality | Internally electrically polished: Ra ≤ 0.38 μm (ASME BPE SF4 / DIN HE4); Internally mechanically polished: Ra ≤ 0.5 μm (ASME BPE SF1) |
| Maximum pilot pressure | 10 bar (7 bar for actuator size 130, 225) |
| Pilot air port | Push-in connector for outer diameter, ∅ 6 mm or 1/4" (standard), thread G 1/8" |
| Operating medium | Neutral gases and liquids, highly purified, sterile, aggressive or abrasive mediums |
| Control medium | Neutral gases, air |
| Ambient temperature | -10 °C...+ 60 °C, autoclavable |
| Symbol | Description |
|---|---|
![]() | Control function A (CF A) Pneumatically operated T-valve Normally closed by spring force |
![]() | Control function B (CF B) Pneumatically operated T-valve Normally opened by spring force |
![]() | Control function I (CF I) Pneumatically operated T-valve on either side Switching position dependent on external control |
WARNING
When using a pilot valve or a control unit mounted on the actuator, observe their permissible temperature ranges.
Ambient Temperature
| Actuator housing material | Actuator size | Permissible ambient temperature [°C] |
|---|---|---|
| PPS | 50 (D), 70 (M), 90 (N), 130 (P) | -10...+60 (Standard) / -10...+100 (Optional) |
| Stainless steel | 225 (L) | -10...+100 |
Medium Temperature for Diaphragms
| Diaphragm material | Medium temperature [°C] | Comments |
|---|---|---|
| EPDM (AD) | -10...+143 | Steam sterilisation max. +150°C for 60 min |
| FKM (FF) | 0...+130 | No steam, dry heat max +150°C for 60 min |
| PTFE (EA) | -10...+130 | Steam sterilisation max. +140°C for 60 min |
| Advanced PTFE (EU) | -5...+143 | Steam sterilisation max. +150°C for 60 min |
| GYLON® (ER) | -5...+130 | Steam sterilisation max. +140°C for 60 min |

| Diaphragm size | Actuator size ∅ | ∅ A | HS with 8691 / 8695 | HS with 8690 / 8697 | H+M (MT86) |
|---|---|---|---|---|---|
| 8 | 50 (D) | 65 | 232 | 219 | 138 |
| 15 | 50 (D) | 65 | 240 | 226 | 146 |
| 15 | 70 (M) | 92 | 262 | 229 | 166 |
| 25 | 90 (N) | 120 | 301 | 269 | 205 |
| 40 | 130 (P) | 160 | 370 | 337 | 274 |
| 50 | 130 (P) | 160 | 379 | 346 | 282 |
| 65 | 130 (P) | 160 | 383 | 350 | 287 |
| 65 | 225 (L) | 245 | 427 | 395 | 330 |

(Dimensions in mm, unless otherwise stated. Refer to full datasheet for comprehensive port connection variants including DIN EN ISO 1127, ASME BPE, and SMS 3008).
TIP
For pipelines, the inclination angles specified in the valid ASME BPE standard are recommended. Ensure that pipelines are free of impurities (seal material, metal chips) before connection.
WARNING
Damage to the diaphragm or the actuator The diaphragm and actuator can be damaged when welding the valve body into the pipeline. Remove the actuator and diaphragm from the valve body before installation.
| Diaphragm size | EPDM, FKM [Nm] | PTFE, advanced PTFE, GYLON® [Nm] |
|---|---|---|
| 8 | 2 | 2.5 |
| 15 | 3.5 | 4 |
| 20 | 4 | 4.5 |
| 25 | 5 | 6 |
| 40 | 8 | 10 |
| 50 | 12 | 15 |
| 65 | 20 | 30 |
| 80 | 30 | 40 |
| 100 | 40 | 50 |
(Tolerance: +10 %)
Explore similar products in our catalog