Skip to content
Direct-actingCompactIP65FKM SealStainless Steel

BURKERT 389544 2/2-Way Direct-Acting Plunger Valve (Type 7011)

Bürkert 389544 (Type 7011) 2/2-way direct-acting plunger valve. Normally closed, 1.2mm orifice, G1/8 internal thread, 24V DC, FKM seal, stainless steel body, 0-42 bar.

BURKERT 389544 2/2-Way Direct-Acting Plunger Valve (Type 7011)

Bürkert 389544 (Type 7011) is a direct-acting and compact small plunger valve up to DN 2.4. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness. Various housing and seal material combinations are available depending on the actual application. In combination with a plug conforming to DIN EN 175301-803 shape B, the valves satisfy degree of protection IP65.

  • Direct-acting and compact small valve up to DN 2.4
  • Slipped over coil system
  • Simple and fast flange or manifold mounting
  • Quick coupling (push-in fitting) for push-in connectors
  • Explosion-proof variants available

General Technical Data

Product properties
Material
SealFKM
BodyStainless steel 1.4305/303
Weight
Standard variant 24.5 mm solenoid coil146 g (with G 1/8)
Standard variant 20 mm solenoid coil120 g (with G 1/8)
OrificeDN 1.2
Circuit functionA (Normally closed)
Thermal insulation class of solenoid coilEpoxy coil class H
Performance data
Duty cycle (Single valve)100 % resp. 50 % continuous operation
Switching timeOpening: 8...15 ms, Closing: 10...17 ms
Electrical data
Operating voltage24 V DC
Voltage tolerance± 10 %
Medium data
Operating mediumNeutral gases and liquids (e.g. compressed air, water, hydraulic oil, technical vacuum)
Medium temperature-10 °C...+100 °C
ViscosityMax. 21 mm²/s
Product connections
Port connectionG 1/8 Internal thread
Approvals and conformities
Degree of protectionIP65 with cable plug
Environment and installation
Installation positionAs required, preferably with actuator upright
Ambient temperatureMax. +55 °C resp. +75 °C (depending on power level)

INFO

Measurement at +20 °C, 6 bar at the valve outlet acc. to DIN ISO 12238:2001, opening: pressure build-up 0…10 %, closing: pressure reduction 100…90 %.

Circuit Functions

Circuit functionDescription
Circuit function A (CF A)2/2-way solenoid valve
Direct-acting
Normally closed

Materials

Bürkert 389544 Type 7011 material specifications for circuit function A

No.ElementMaterial
1NutDIN 176 Surface finish thick film passivated KOSA0101
2StopperStainless steel 1.4113/434
3Core guide tubeStainless steel 1.4303 ST/305L
4Shading ringCopper (optional silver)
5CoreStainless steel 1.4113/434
6SpringStainless steel 1.4310/301
7SealFKM
8Valve bodyStainless steel 1.4305/303
9O-ringFKM
10FlangeNickel-plated surface (stainless steel variant)
11CoilEpoxy

Dimensions

Threaded variant

Note

Dimensions in mm. Variants according to industry standard form B.

Bürkert 389544 Type 7011 dimensions for threaded variant

Port connectionA [mm]B [mm]C [mm]D [mm]
Thread CF A (G 1/8)8251510

Approvals and Conformities

  • Explosion protection: Optional explosion protection (valid for coils with fixed cable outlet). ATEX: EPS 21 ATEX 1 128 X (II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db). IECEx: IECEx EPS 21.0045X.
  • North America (USA/Canada): Valid for coils: UL Recognized for the USA and Canada according to UL 429 and CAN/CSA-C22.2 No. 139.
  • Drinking water: Suitable for use in drinking water applications. The materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV).
  • Foods and beverages/Hygiene: FDA – Code of Federal Regulations (valid for the variable code PL02, PL03). USP – United States Pharmacopeial Convention (valid for the variable code PL04). EC Regulation 1935/2004.