BURKERT 389711 (Type 7011) is a direct-acting 2/2-way normally closed plunger valve. Features a brass body, FKM seal, flange connection, 2.0mm orifice, and operates at 24V/50Hz.

The BURKERT 389711 (Type 7011) is a direct-acting and compact small plunger valve up to DN 2.4. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness. A Bürkert-specific flange variant (SFB) enables the space-saving arrangement of valves on a multiple manifold. In combination with a plug conforming to DIN EN 175301-803 shape B, the valve satisfies degree of protection IP65.
| Product properties | Specification |
|---|---|
| Orifice | DN 2.0 mm |
| Circuit function | A (Normally closed) |
| Thermal insulation class | Epoxy coil class H |
| Duty cycle | 100% continuous operation |
| Switching time | Opening: 8...15 ms, Closing: 10...17 ms |
| Operating voltage | 24 V / 50 Hz |
| Voltage tolerance | ± 10 % |
| Operating medium | Neutral gases and liquids (e.g. compressed air, water, hydraulic oil, technical vacuum) |
| Medium temperature | -10 °C...+100 °C |
| Viscosity | Max. 21 mm²/s |
| Port connection | Flange (FK01) |
| Degree of protection | IP65 with cable plug |
| Installation position | As required, preferably with actuator upright |
Circuit function A (CF A): 2/2-way solenoid valve, Direct-acting, Normally closed.
Standard variant circuit function A

| No. | Element | Material |
|---|---|---|
| 1 | Nut | DIN 176 Surface finish thick film passivated KOSA0101 |
| 2 | Stopper | Stainless steel 1.4113/434 |
| 3 | Core guide tube | Stainless steel 1.4303 ST/305L |
| 4 | Shading ring | Copper (optional silver) |
| 5 | Core | Stainless steel 1.4113/434 |
| 6 | Spring | Stainless steel 1.4310/301 |
| 7 | Seal | FKM |
| 8 | Valve body | Brass |
| 9 | O-ring | FKM |
| 10 | Flange | Surface finish thick film passivated KOSA0101 (brass variant) |
| 11 | Coil | Epoxy |
INFO
Dimensions in mm. Variants according to industry standard form B.

| Port connection | A [mm] | B [mm] | C [mm] | D [mm] |
|---|---|---|---|---|
| Flange CF A | - | - | 20 | 10 |
TIP
On the connection side, the geometries are to be realised as shown in the following drawing. Flange variant (FK01) according to FST 1000225877.

Power consumption (Standard variant, coil size 24.5 mm)
| Coil | Orifice [mm] | Inrush AC [VA] | Hold AC [VA] | Hold AC [W] | Opening [ms] | Closing [ms] |
|---|---|---|---|---|---|---|
| 24 V / 50 Hz / 6 W | 2.0 | 14 | 8 | 6 | 8...15 | 10...17 |
Measurement at +20 °C, 6 bar at the valve outlet acc. to DIN ISO 12238:2001, opening: pressure build-up 0...10 %, closing: pressure reduction 100...90 %.
Risk of injury due to high pressure
Before working on the system or device, switch off the pressure and ventilate and empty the lines.
Risk of injury from electric shock
Before working on the system or device, switch off the power supply and secure against reactivation. Always connect the protective conductor and check electrical continuity between the solenoid and the body.
Installation Guidelines
Explore similar products in our catalog