BURKERT 453692 (Type 0330) is a direct-acting, media-separated 3/2-way solenoid valve (Circuit Function C). Features a brass body, FKM seal, NPT 1/4 connection, and operates at 24V DC (0-12 bar).

BURKERT 453692 (Type 0330) is a direct-acting, media-separated pivoted armature solenoid valve designed for controlling, shutting off, and dosing neutral and aggressive media. This specific model (SKU 453692) is configured as a 3/2-way valve with Circuit Function C (normally closed). It features a robust brass body, FKM (Fluor rubber) seals, and an NPT 1/4 internal thread connection. The valve operates on a 24V DC power supply and supports a pressure range of 0 to 12 bar, making it highly suitable for critical industrial applications where reliable media separation and fast actuation are required.
The solenoid coils are moulded with a chemically resistant epoxy, and the coil system is separated from the medium by a diaphragm system. This maintenance-free pivoted armature technology ensures a long service life and vibration-proof operation. The valve is equipped with a service-friendly, robust manual override for easy start-up and testing.
| Property | Value |
|---|---|
| Orifice | DN 2.0 mm (5/64 inch) |
| Circuit Function | C (3/2-way, normally closed) |
| Body Material | Brass |
| Seal Material | FKM (Fluor rubber) |
| Port Connection | NPT 1/4 Internal thread |
| Operating Voltage | 24 V DC |
| Nominal Pressure | 0 - 12 bar (liquid/gas) |
| Kv Value (Water) | 0.08 m³/h |
| QNn Value (Gas) | 85 l/min |
| Medium Temperature | 0 °C to +90 °C |
| Ambient Temperature | Max. +55 °C |
| Degree of Protection | IP65 (with correctly connected cable plug) |
| Duty Cycle | 100% continuous operation |
| Electrical Connection | Plug contacts according to DIN EN 175301-803 Form A |
This specific model operates with Circuit Function C (CF C):

| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Diaphragm | FKM |
| 3 | O-ring | FKM |
| 4 | Seat | Brass |
| 5 | Valve body | Brass |

| D1 | L1 | D2 | L2 |
|---|---|---|---|
| G 1/8 | 9 | - | - |
| G 1/4 | 9 | NPT 1/4 | 7.5 |
Note
The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. For Circuit Function C, the valve is connected according to the 3-way pin assignment.
| Circuit function | Connection 1 | Connection 2 | Connection 3 | 2-way | 3-way |
|---|---|---|---|---|---|
| C | P | A | R | ![]() | ![]() |
| Circuit function | DN [mm] | Kv value water DC [m³/h] | Pressure range Standard DC [bar] | Pressure range Vacuum [bar] |
|---|---|---|---|---|
| C | 2.0 | 0.08 | 0...12* | -0.98...10 |
Pressure Limitation
Functional Safety
During a long period of downtime, at least 1–2 switching operations per restart are recommended to ensure functional safety and prevent the core from seizing.
Explore similar products in our catalog