Skip to content
Direct-ActingMedia-SeparatedIP65UL/CSA Approved

BURKERT 458950 Type 0330 Direct-Acting 2/2-Way Solenoid Valve

BURKERT 458950 (Type 0330) is a direct-acting, media-separated 2/2-way normally open solenoid valve. Features a brass body, FKM seal, NPT 1/4 connection, and operates at 240V 60Hz.

BURKERT 458950 Type 0330 Direct-Acting 2/2-Way Solenoid Valve

BURKERT 458950 (Type 0330) is a direct-acting, media-separated pivoted armature solenoid valve. This specific model is configured as a 2/2-way normally open valve (Circuit Function B) with a 3.0 mm orifice. It features a robust brass body, FKM (fluor rubber) seals, and an NPT 1/4 internal thread connection. Designed for reliable operation, it runs on 240V 60Hz power and handles pressures from 0 to 10 bar.

The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a diaphragm, the valve is highly suitable for critical media. The 0330 series is equipped with a service-friendly, robust manual override for start-up and testing.

BURKERT 458950 Type 0330 direct-acting solenoid valve

General Technical Data

PropertyValue
OrificeDN 3.0 mm
Circuit functionB (2/2-way, normally open)
Body materialBrass
Seal materialFKM
Port connectionNPT 1/4
Voltage240 V / 60 Hz
Pressure range0 to 10 bar
Medium temperature0 °C to +90 °C
Ambient temperatureMax. +55 °C
Duty cycle100% continuous operation
Degree of protectionIP65 with cable plug
Thermal insulation classEpoxy coil class H

Circuit Function

SymbolDescription
BURKERT 458950 Type 0330 circuit function B normally openCircuit function B (CF B)
2/2-way solenoid valve
Direct-acting
Normally open

Material Specifications

No.ElementMaterial
1CoilEpoxy
2DiaphragmFKM
3O-ringFKM
4SeatBrass
5Valve bodyBrass

Dimensions

Metal Body (Brass)

Note

  • Dimensions in mm
  • For metal bodies, the minimum thread length at the middle connection is 7.5 mm.
  • The dimensions D2 and L2 apply to NPT thread.
D1L1D2L2
G 1/89--
G 1/49NPT 1/47.5

BURKERT 458950 Type 0330 metal body dimensions

Product Connections

Pin Assignment Standard Variant

The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. For Circuit Function B, the connection is as follows:

Circuit functionConnection 1Connection 2Connection 32-way
BBP-BURKERT 458950 Type 0330 pin assignment for standard variant

Safety and Installation

DANGER!

Risk of injury from high pressure in the system/device ▶ Before working on equipment or device, switch off the pressure and deaerate/drain lines.

Risk of injury from electric shock ▶ Before working on the system or device, switch off the power supply and secure against reactivation. ▶ Observe the applicable accident prevention and safety regulations for electrical devices.

WARNING!

Risk of injury due to improper installation ▶ Installation may only be performed by trained technicians and with the appropriate tools. ▶ Secure the system against unintentional activation. ▶ Ensure a controlled restart after installation.

Before Installation:

  • The installation position is flexible. Preferably: actuator at the top.
  • Check pipelines for soiling and clean if required.
  • For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet.