Burkert Type 0330 (Article 461284) direct-acting 2/2-way pivoted armature solenoid valve. Features a brass body, NPT 1/4 connection, FKM seal, and 24V DC operation.

Burkert Type 0330 (Article 461284) is a direct-acting, media-separated pivoted armature solenoid valve. It features maintenance-free pivoted armature technology and a vibration-proof, block screwed coil system. The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a diaphragm, the valve is especially suitable for critical media such as aggressive acids and alkalis. The 0330 is equipped with a service-friendly, robust manual override for start-up and testing.
| Property | Value |
|---|---|
| Orifice | DN 2...DN 5 (Model 461284: 3.0 mm) |
| Body Material | Brass, Stainless steel (1.4401), PP, PVDF, PEEK |
| Seal Material | EPDM, FKM, FFKM, NBR |
| Duty Cycle | 100% continuous operation (for brass, stainless steel, PEEK) |
| Voltage | 24 V DC (Model 461284) |
| Voltage Tolerance | ±10% |
| Degree of Protection | IP65 with cable plug |
| Thermal Insulation Class | Epoxy coil class H |
| Symbol | Description |
|---|---|
![]() | Circuit function A (CF A) 2/2-way solenoid valve Direct-acting Normally closed |
![]() | Circuit function B (CF B) 2/2-way solenoid valve Direct-acting Normally open |
![]() | Circuit function C (CF C) 3/2-way solenoid valve Direct-acting Normally closed |
![]() | Circuit function D (CF D) 3/2-way solenoid valve Direct-acting Normally open |
![]() | Circuit function E (CF E) 3/2-way mixing valve (solenoid valve) |
![]() | Circuit function F (CF F) 3/2-way distribution valve (solenoid valve) Direct-acting |
![]() | Circuit function T (CF T) 3/2-way solenoid valve Direct-acting Flow direction optional Normally closed |
| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Diaphragm | EPDM, FKM, FFKM, NBR |
| 3 | O-ring | EPDM, FKM, FFKM, NBR |
| 4 | Seat | Brass, Stainless steel (1.4401), PP, PEEK |
| 5 | Valve body | Brass, Stainless steel (1.4401), PP, PEEK |
Metal Body (Standard Variant)
Note

| D1 | L1 | D2 | L2 |
|---|---|---|---|
| G 1/8 | 9 | - | - |
| G 1/4 | 9 | NPT 1/4 | 7.5 |
Pressure range and flow rate (Metal body, Standard variant)
| Circuit function | DN [mm] | Kv value water DC [m³/h] | Kv value water AC [m³/h] | Pressure range Standard [bar] | Pressure range Vacuum [bar] |
|---|---|---|---|---|---|
| A / B / C / D / F | 2 | 0.08 | 0.11 | 0...16 | -0.98...10 |
| A / B / C / D / F | 3 | 0.14 | 0.18 | 0...10 | -0.98...6 |
| A / B / C / D / F | 4 | 0.17 | 0.23 | 0...5 | -0.98...3 |
| A / B / C / D / F | 5 | 0.29 | 0.29 | 0...2.5 | -0.98...1 |
| E | 2 | 0.08 | 0.11 | 0...10 | -0.98...8 |
| E | 3 | 0.14 | 0.18 | 0...6 | -0.98...5 |
| E | 4 | 0.17 | 0.23 | 0...3 | -0.98...2.5 |
| E | 5 | 0.29 | 0.29 | 0...1.5 | -0.98...1 |
| T | 2 | 0.08 | 0.11 | 0...12 | -0.98...8 |
| T | 3 | 0.14 | 0.18 | 0...8 | -0.98...5 |
| T | 4 | 0.17 | 0.23 | 0...4 | -0.98...2.5 |
DANGER!
Risk of injury from high pressure in the system/device. Before working on equipment or device, switch off the pressure and deaerate/drain lines.
Pin assignment standard variant
The pin assignment depends on the circuit function.
| Circuit function | Connection 1 | Connection 2 | Connection 3 |
|---|---|---|---|
| A | P | A | - |
| B | B | P | - |
| C | P | A | R |
| D | R | B | P |
| E | P1 | A | P2 |
| F | A | P | B |
| T | NC | IN/OUT | NO |